• Title/Summary/Keyword: Master Robot

Search Result 133, Processing Time 0.024 seconds

The Present and Future of Medical Robots: Focused on Surgical Robots (의료로봇의 현재와 미래: 수술로봇을 중심으로)

  • Song, Mi Ok;Cho, Yong Jin
    • Journal of Digital Convergence
    • /
    • v.19 no.4
    • /
    • pp.349-353
    • /
    • 2021
  • This study is a review study attempted to analyze the current situation of surgical robots based on previous research on surgical robots in the era of the 4th revolution, and to forecast the future direction of surgical robots. Surgical robots have made full progress since the launch of the da Vinci and the surgical robot is playing a role of supporting the surgeries of the surgeons or the master-slave method reflecting the intention of the surgeons. Recently, technologies are being developed to combine artificial intelligence and big data with surgical robots, and to commercialize a universal platform rather than a platform dedicated to surgery. Moreover, technologies for automating surgical robots are being developed by generating 3D image data based on diagnostic image data, providing real-time images, and integrating image data into one system. For the development of surgical robots, cooperation with clinicians and engineers, safety management of surgical robot, and institutional support for the use of surgical robots will be required.

Design and Control of a Wearable Robot (Wearable Robot Arm의 제작 및 제어)

  • Jeong, Youn-Koo;Kim, Yoon-Kyong;Kim, Kyung-Hwan;Park, Jong-Oh
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.277-282
    • /
    • 2001
  • As human-friendly robot techniques improve, the concept of the wearability of robotic arms becomes important. A master arm that detects human arm motion and provides virtual forces to the operator is an embodied concept of a wearable robotic arm. In this study, we design a 7 DOF wearable robotic arm with high joint torques. An operator wearing this robotic arm can move around freely because this robotic arm was designed to have its fixed point at the shoulder part of the operator. The proposed robotic arm uses parallel mechanisms at the shoulder part and the wrist part on the model of the human muscular structure of an upper limb. To reduce the computational load in solving the forward kinematics and to prevent singularity motions of the parallel mechanism, yawing motion of the parallel mechanisms was separated using a slip ling mechanism. The total weight of the proposed robotic arm is about 4 kg. An experimental result of force tracking test for the pneumatic control system and an application example for VR robot are described to show the validity of the robot.

  • PDF

A Research on the Design and Development of a Robot System with Multi-fingered Hands (다지 로봇 시스템의 설계 및 개발에 관한 연구)

  • Lee, Ho-Youn;Lee, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.138-141
    • /
    • 2002
  • In this paper, we developed a Master Hand which has 20 potentiometer for getting grasping data of human hands, a Slave Hand which has 20 DOF and five fingers with servo-motors, and a controller for the 7 DOF Arm with Multi-fingered hands. And, we programmed a 3D simulation S/W which controls a Robot System with Multi-fingered hands. A developed Robot System showed good performance in the grasping of an object with known position and shape.

  • PDF

Robotic Needle Insertion Using Corneal Applanation for Deep Anterior Lamellar Keratoplasty (각막 압평을 이용한 로봇 바늘 삽입법: 심부표층각막이식수술에의 적용)

  • Park, Ikjong;Shin, Hyung Gon;Kim, Keehoon;Kim, Hong Kyun;Kyun., Wan
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.1
    • /
    • pp.64-71
    • /
    • 2021
  • This paper describes a robotic teleoperation system to perform an accurate needle insertion into a cornea for a separation between the stromal layer and Descemet's membrane during deep anterior lamellar Keratoplasty (DALK). The system can reduce the hand tremor of a surgeon by scaling the input motion, which is the control input of the slave robot. Moreover, we utilize corneal applanation to estimate the insertion depth. The proposed system was validated by performing the layer separation using 25 porcine eyes. The average depth of needle insertion was 742 ± 39.8 ㎛ while the target insertion depth was 750 ㎛. Tremor error was reduced from 402 ± 248 ㎛ in the master device to 28.5 ± 21.0 ㎛ in the slave robot. The rate of complete success, partial success, and failure were 60, 28, and 12%, respectively. The experimental results showed that the proposed system was able to reduce the hand tremor of surgeons and perform precise needle insertion during DALK.

Impedance Model based Bilateral Control for Force reflection of a Laparoscopic Surgery Robot (복강경 수술 로봇의 힘 반향을 위한 임피던스 모델 기반의 양방향 제어)

  • Yoon, Sung-Min;Kim, Won-Jae;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.801-806
    • /
    • 2014
  • LAS (Laparoscopy Assisted Surgery) has been substituted alternatively for traditional open surgery. However, when using a commercialized robot assisted laparoscopic such as Da Vinci, surgeons have encountered some problems due to having to depend only on information by visual feedback. To solve this problem, a haptic function is required. In order to realize the haptic teleoperation system, a force feedback and bilateral control system are needed. Previous research showed that the perturbation value estimated by a SPO (Sliding Perturbation Observer) followed a reaction force that loaded on the surgical robot instrument. Thus, in this paper, the force feedback problem of surgical robots is solved through the reaction force estimation method. This paper then introduces the possibility of the haptic function realization of a laparoscopic surgery robot using a bilateral control system. For bilateral control, the master uses an impedance control and the slave uses a SMC (Sliding Mode Control). The experiment results show that a torque and force sensorless teleoperation system can be implemented using a bilateral control structure.

A Development of Rehabilitation System for Upper Limb Using Robot Manipulator (로봇을 이용한 상지 재활 시스템에 관한 연구)

  • 원주연;심형준;한창수
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.309-318
    • /
    • 2003
  • In this paper a 6 degree-of-freedom robot was studied for medical purpose. In the past the robot used for industry field was utilized for medical robot but in these days the robot used for rehabilitation. welfare, and service. This system was Proposed for a stroke patient or a patient who can not use one arm. A master-slave system was constructed to exercise either paralysis or abnormal arm using normal arms movement. Study on the human body motion result was applied to calculate a movement range of humans elbow and shoulder. In addition, a force-torque sensor is applied to estimate the rehabilitation extent of the patient in the slave robot. Therefore, the stability of the rehabilitation robot could be improved. By using the rehabilitation robot, the Patient could exercise by himself without any assistance In conclusion. the proposed system and control algorithm were verified by computer simulation and system experiment.

Development of Autonomous Algorithm Using an Online Feedback-Error Learning Based Neural Network for Nonholonomic Mobile Robots (온라인 피드백 에러 학습을 이용한 이동 로봇의 자율주행 알고리즘 개발)

  • Lee, Hyun-Dong;Myung, Byung-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.5
    • /
    • pp.602-608
    • /
    • 2011
  • In this study, a method of designing a neurointerface using neural network (NN) is proposed for controlling nonholonomic mobile robots. According to the concept of virtual master-slave robots, in particular, a partially stable inverse dynamic model of the master robot is acquired online through the NN by applying a feedback-error learning method, in which the feedback controller is assumed to be based on a PD compensator for such a nonholonomic robot. The NN for the online feedback-error learning can composed that the input layer consists of six units for the inputs $x_i$, i=1~6, the hidden layer consists of two hidden units for hidden outputs $o_j$, j=1~2, and the output layer consists of two units for the outputs ${\tau}_k$, k=1~2. A tracking control problem is demonstrated by some simulations for a nonholonomic mobile robot with two-independent driving wheels. The initial q value was set to [0, 5, ${\pi}$].

Tele-operation of a Mobile Robot Using Force Reflection Joystick with Single Hall Sensor (단일 홀센서 힘반영 조이스틱을 이용한 모바일 로봇 원격제어)

  • Lee, Jang-Myung;Jeon, Chan-Sung;Cho, Seung-Keun
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • Though the final goal of mobile robot navigation is to be autonomous, operators' intelligent and skillful decisions are necessary when there are many scattered obstacles. There are several limitations even in the camera-based tele-operation of a mobile robot, which is very popular for the mobile robot navigation. For examples, shadowed and curved areas cannot be viewed using a narrow view-angle camera, especially in bad weather such as on snowy or rainy days. Therefore, it is necessary to have other sensory information for reliable tele-operations. In this paper, sixteen ultrasonic sensors are attached around a mobile robot in a ring pattern to measure the distances to obstacles. A collision vector is introduced in this paper as a new tool for obstacle avoidance, which is defined as a normal vector from an obstacle to the mobile robot. Based on this collision vector, a virtual reflection force is generated to avoid the obstacles and then the reflection force is transferred to an operator who is holding a joystick to control the mobile robot. Relying on the reflection force, the operator can control the mobile robot more smoothly and safely. For this bi-directional tele-operation, a master joystick system using a hall sensor was designed to resolve the existence of nonlinear sections, which are usual for a general joystick with two motors and potentiometers. Finally, the efficiency of a force reflection joystick is verified through the comparison of two vision-based tele-operation experiments, with and without force reflection.

  • PDF

Development of Diaphragm-type Stylus Probe for Ultra-precision On-machine Measurement Application (초정밀 기상측정용 다이아프램 타입 접촉식 프로브의 개발)

  • Lee, Jung-Hoon;Lee, Chan-Hee;Choi, Joon-Myeong;Kim, Ho-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.845-852
    • /
    • 2012
  • The diaphragm-type stylus probe was developed for ultra-precision on-machine measurement (OMM) application. This probe is equipped with two diaphragms which are parallel and one capacitive sensor is used for detecting the vertical motion of end tip in the stylus when it is contacted to the optical freeform surface. For better performance of proposed probes, several design parameters such as axial stiffness and the lateral deformations were investigated with finite element analysis techniques. To verify the feasibility, the profiles of the master sphere ball were measured on the ultra-precision milling machine. The measurement results show that the proposed probe can calculate the radius of the circle within the accuracy of 0.1 ${\mu}m$ for the ultraprecision optical surface.