• 제목/요약/키워드: Mass transfer resistance

검색결과 133건 처리시간 0.032초

(TiB+TiC) 입자강화 Ti기 복합재료의 접촉하중에 따른 내마모 특성 (Effect of Contact Load on Wear Property of (TiB+TiC) Particulates Reinforced Titanium Matrix Composites)

  • 최봉재
    • 한국주조공학회지
    • /
    • 제37권4호
    • /
    • pp.115-122
    • /
    • 2017
  • The aim of this research is to evaluate the wear properties of (TiB+TiC) paticulate reinforced titanium matrix composites (TMCs) by in-situ synthesis. Different particle sizes (1500, $150{\mu}m$) and contents (0.94, 1.88 and 3.76 mass% for Ti, 1.98 and 3.96 mass% for the Ti6Al4V alloy) of boron carbide were added to pure titanium and to a Ti6Al4V alloy matrix during vacuum induction melting to provide 5, 10 and 20 vol.% (TiB+TiC) particulate reinforcement amounts. The wear behavior of the (TiB+TiC) particulate reinforced TMCs is described in detail with regard to the coefficient of friction, the hardness, and the degree of reinforcement fragmentation during sliding wear. The worn surfaces of each sliding wear condition are shown for the three types of wear studied here: transfer layer wear, particle cohesion wear and the development of abrasive areas. The fine reinforcements of TMCs were easily fragmented from the Ti matrix as compared to coarse reinforcements, and fragmented debris accelerated the decrease in the wear resistance.

Swift Synthesis of CVD-graphene Utilizing Conduction Heat Transfer

  • Kim, Sang-Min;Mag-isa, Alexander E.;Oh, Chung-Seog;Kim, Kwang-Seop;Kim, Jae-Hyun;Lee, Hak-Joo;Yoon, Jonghyuk;Lee, Eun-Kyu;Lee, Seung-Mo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.652-652
    • /
    • 2013
  • The conventional thermal chemical vapor deposition (CVD) setup for the graphene synthesis has mainly used convective heat transfer in order to heat a catalyst (e.g. Cu) up to $1,000^{\circ}C$. Although the conventional CVD has been so far widely accepted as the most appropriate candidate enabling mass-production of high-quality graphene, this method has stillremained under the standard for the commercialization largely due to the poor productivity arisen out of the required long processing time. Here, we introduced a fast and efficient synthetic route toward CVD-graphene. Unlike the conventional CVD using convection heat transfer, we adopted a CVD setup utilizing conduction heat transfer between Cu catalyst and rapid heating source. The high thermal conductive nature of Cu and the employed rapid heating source led to the remarkable reduction in processing timeas compared to the conventional convection based CVD (Fig. 1A), moreover, the synthesized graphene was turned out to have comparable quality to that synthesized by the conventional CVD (Fig. 1B). For the optimization of the conduction based CVD process, the parametric studies were thoroughly performed using through Raman spectroscopy and electrical sheet resistance measurement. Our approach is thought to be worth considerable in order to enhance productivity of the CVD graphene in the industry.

  • PDF

광합성 박테리아를 이용한 고성능 수소 생산 고정화 생물반응기의 개발(II) :고정층 반응기와 연속 교반탱크 반응기에서의 수소 생산성 및 물질전달 저항 비교 (Development of Bioreactors for Hydrogen-Producing Immobilized Photosynthetic Bacteria(II) : Evaluation of Immobilized Bioreactor for Hydrogen Productivity and Mass Transfer Resistance)

  • 선용호;한정우
    • KSBB Journal
    • /
    • 제8권3호
    • /
    • pp.256-265
    • /
    • 1993
  • 본 연구는 광합성 미생물 R. rubrum KS-301을 이용한 연속 반응기인 고정층 반응기와 연속 교반탱크 반응기에서 실험을 수행하여 도입 포도당 농도, 희석속도에 대한 수소 생산성과 고정화 담체에 의해서 형성되는 내부, 외부 및 총괄 물질전달 저항, 반응 속도식 변수 등을 평가한 후 비교하였다. 고정층 반응기에서의 겉보기 $K_m$은 희석속도의 증가에 따라 감소하며, 연속 교반탱크 반응기의 경우는 희석속도 $0.4h^{-1}$ 이상에서는 거의 일정한 값을 나타내었다. 고정층 반응기에서의 수소 생산성과 물질전달 실험결과는 연속 교반탱크 반응기에서와 비슷한 경향을 보이나 두 반응기를 비교하면 수소 생산성과 외부 효율인자는 교반탱크 반응기일 때가 크고, 내부 효율인자는 고정층 반응기일 때가 컸다. 그러나 총괄 효율인자는 두 반응기가 도입 포도당 농도에 따라서는 비슷한 수치를 나타내었다.

  • PDF

냉각유로 형상변화에 따른 유동 및 열저항 최적화 연구 (Optimizing the Configurations of Cooling Channels with Low Flow Resistance and Thermal Resistance)

  • 조기현;안호선;김무환
    • 대한기계학회논문집B
    • /
    • 제35권1호
    • /
    • pp.9-15
    • /
    • 2011
  • 본 연구에서는 3 차원 전산 열유동해석을 통하여 형상법칙에 근거하여 개발된 냉각판의 열수력학적인 특성을 분석하였다. 서펜타인 형상을 포함하여 최적화, 최적화되지 않은 1, 2 차 형상 총 5 개 형상을 대상으로 동일한 구속조건을 부여함으로써 유동저항, 열저항 및 분지유로에서의 유동균일도를 상호 비교함으로써 냉각판의 성능평가를 수행하였다. 그 결과, 최적화된 1, 2 차 형상 구조가 최적화되지 않은 경우와 비교하여 훨씬 적은 압력손실을 나타내었으며, 압력손실을 기준으로 최적화된 2 차 형상 구조가 가장 우수한 유동 구조를 나타내었다. 또한, 최적화된 1, 2 차 형상구조의 열저항 및 유동 분배성능도 기존에 사용되는 유로형상과 비교하여 모두 우수한 성능을 보였다.

다공성 매질 개념을 이용한 응축기의 응축 열전달에 관한 수치 해석 (Numerical analysis of condensation in the condenser using the porous medium approach)

  • 제준호;최치웅;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2261-2266
    • /
    • 2007
  • In this study, the numerical analysis to estimate condensation heat and mass transfer of the condenser was carried out using the PMA (porous medium approach). In the PMA, the details of tube bundle in the condenser are replaced by the porous medium, and the flow resistance term is added in the momentum equation. In this regard, the PMA is quite helpful for the study of tube bundle in the large condenser. The pressure loss through tube bundle can be compensated by viscous and inertial momentum sink terms, which was validated numerically. Value of the pressure drop was compared to that of Butterworth correlation. Three dimensional analysis of condensation for McAllister condenser with the PMA was conducted using Fluent 6.2 and UDFs (use-defined functions). The result of condensation rate was analogous to previous results (experimental and numerical data).

  • PDF

코 내부 유동의 PIV 해석 (Particle Image Velocimetry Measurements in Nasal Airflow)

  • 김성균;손영락
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.566-569
    • /
    • 2001
  • Researchers have invectigated nasal flow both numerically and experimentally for centuries. Experimental studies most have suffered from various limitations necessary to allow the measurements to be obtained with available equipment. Nasal airflow can be subdivided into two interrelated categories; nasal airflow resistance and heat and mass transfer between the air stream and the walls of the nasal cavity. In this study, thanks to a new method for model casting by a combination of Rapid prototyping and Solidification of clear silicone, a transparent rectangular box containing the complex nasal cavity is made for PIV experiments. The CBC PIV algorithm is used for analysis.

  • PDF

고정화제와 고정화된 해조류에 의한 납의 제거 특성 (Removal Characteristics of Lead by Immobilizing Agents and Immobilized Seaweed)

  • 이학성;서정호;서근학
    • 한국환경보건학회지
    • /
    • 제27권1호
    • /
    • pp.83-87
    • /
    • 2001
  • In this study, the characteristics of lead removal by PVA and alginate bead which used widely as immobilizing agents were investigated, and the difference of removal amounts between pure PVA/alginate bead and Sargassum thunbergii immobilized bead was studied. All PVA beads, pure and S. thunbergii immobilized, reached an equilibrium state in about 1 hour, and S. thunbergii immobilized bead adsorbed more lead than pure one. But in the case of alginate beads, they needed much time, about 5 hours, to reach an equilibrium state, and adsorbed lead four times higher than PVA beads. Therefore, it was considered that alginate beads had more mass transfer resistance and function groups which adsorb lead such as hydroxyl, carboxyl and etc. than PVA bead. To examine the continuous usage of alginate beads, the process of adsorption/desorption of lead was conducted repeatedly. As the process proceeded, the amounts of lead adsorption decrease, so it was indicated that the non-desorbed lead from alginate bead at first adsorption/desorption process remained constantly.

  • PDF

코 내부 유로(비강) 내부 유동의 PIV해석 (Particle Image Velocimetry Measurements in Nasal Airflow)

  • 김성균
    • 대한기계학회논문집B
    • /
    • 제26권6호
    • /
    • pp.811-816
    • /
    • 2002
  • For the first time, airflow in the nasal cavity of a normal Korean adult is investigated experimentally by PIV measurement. Nasal airflow can be subdivided into two interrelated categories; nasal airflow resistance and heat and mass transfer between the air stream and the walls of the nasal cavity. In this study, thanks to a new method for the model casting by a combination of the rapid prototyping and curing of clear silicone. a transparent rectangular box containing the complex nasal cavity can be made fur PIV experiments. The CBC PIV algorithm is used for analysis. Average and RMS distributions are obtained for inspirational and expiration nasal airflows. Data fer the airflow at the end of meatuses are obtained for the first time. Comparisons between western and Korean nasal airflows are appreciated. Due to the difference in geometry of the frontal part of nasal cavity, the flow near nares shows the difference.

귀금속촉매 (Pt, Pd)를 이용한 일산화탄소 산화반응에 관한 연구 (A Study of Carbon Monoxide Oxidation on Pt & Pt-Pd Catalysts)

  • ;이원묵;유홍진
    • 한국대기환경학회지
    • /
    • 제1권1호
    • /
    • pp.43-51
    • /
    • 1985
  • This study is concerned with the oxidation of carbon monoxide on platinum and platinum-palladium catalysts. Catalysts were made by the impregnation method and flow reactor was used in the catalytic reaction. As for the mixed gases, carbon monoxide concentration varied from 1 to 4% and that of oxygen from 1 to 4%. $N_2$ was used as carrier gas and GHSV varied from 24, 000 $h^{-1} to 60, h^{-1}$. The temperature range was from 200 to $600^\circ$C. It was also taken into consideration that the heat and mass transfer resistance of our catalysts was negligible in the study. Experimental results showed that platinum-palladium catalyst was about 1.5-3.9% superior to platinum catalyst in conversion yield. When we used platinum-palladium catalyst, we observed that carbon monoxide oxidation was found to be 1 st order with respect to carbon monoxide concentration. Activation energy of the catalyst was 23.5 kcal/mol.

  • PDF

증발을 고려한 회전코팅 공정에 대한 수치해석적 연구 (A Numerical Study on the Combined Flow and Evaporation During Spin Coating Process)

  • 임익태;김광선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.59-64
    • /
    • 2001
  • The fluid flow, mass transfer and film thickness variation during a wafer spin coating process are numerically studied. Governing equations for the cylindrical coordinates are simplified using the similarity transformation and solved efficiently using the finite difference method. Concentration dependent viscosity and the binary diffusivity of the coating liquid are used in the analysis. The time variational velocity components of the coating liquid and the film thickness are analyzed according to the various spin speed. When the evaporation is considered, the flow decease in the early times due to the increase of the viscosity and the resultant flow resistance. Effects of the two film thinning mechanism, the flow-out and evaporation are also considered in the analysis.

  • PDF