• Title/Summary/Keyword: Mass of recovery water

Search Result 147, Processing Time 0.021 seconds

Effects of Ionic Speciation of Lysine on Its Adsorption and Desorption Through a Sulfone-type Ion-Exchange Column

  • Choi, Dong-Hyouk;Lee, Ki-Say
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.9
    • /
    • pp.1527-1532
    • /
    • 2007
  • Lysine produced during microbial fermentation is usually recovered by an ion-exchange process, in which lysine is first converted to the cationic form (by lowering the pH to less than 2.0 with sulfuric acid) and then fed to a cationexchange column containing an exchanger that has a sulfone group with a weak counterion such as NH;. Ammonia water with a pH above 11 is then supplied to the column to displace the purified lysine from the column and allow its recovery. To enhance the adsorption capacity and for a possible reduction in chemical consumption, monovalent lysine fed at pH 4 was investigated in comparison with conventional divalent lysine fed at pH 1.5. The adsorption capacity increased by more than 70% on a mass basis using pH 4 feeding compared with pH 1.5 feeding. Lysine adsorbed at pH 4 started to elute earlier than that adsorbed at pH 1.5 when ammonia water was used as the eluant solution, and the extent of early elution became more notable at lower concentrations of ammonia. Moreover, the elution of monovalent lysine fed at pH 4 displayed a stiffer front boundary and higher peak concentration. However, when the ammonium concentration was greater than 2.0 N, complete saturation of the bed was delayed during adsorption and the percent recovery yield from elution was lowered., both drawbacks that were considered inevitable features originating from the increased adsorption of monovalent lysine.

Improvement of skin barrier function using lipid mixture

  • Park, Won-Seok;Son, Eui-Dong;Nam, Gae-Won;Park, Jong-Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.27 no.1
    • /
    • pp.53-72
    • /
    • 2001
  • Dry skin is caused mainly by the perturbation of stratum corneum lipids which affected by ageing, change of season, excess use of surfactant and the effect of disease like atopic dermatitis and psoriasis. Intercellular lipid structures in stratum corneum are responsible for the barrier function of mammalian skin. The major lipd classes that can be extracted from stratum corneum are ceramides, cholesterol and fatty acid, which make up approximately 50, 25, 10 percent of the stratum corneum lipid mass, respectively. Small amount of cholesterol sulfate, phospholipids, glycosylceramide and cholesterol esters are also present. Recent studies have shown that application of one or two these lipids to the perturbed skin delays barrier recovery; only equimolar mixtures allow normal recovery. We observed that barrier recovery rate was improved in hairless mouse by topical application of single neutral lipids (ceramide, free fatty acid, cholesterol) and lipid mixtures. Whereas the application of single lipid didn’t allows a significant enhancement comparing with normal barrier repair, the equimolar mixtures of 3 components(including synthetic pseudoceramide PC104) improved barrier repair, as assessed by the transepidermal water loss. At clinical study to the volunteers aged over sixty, skin dryness recuperated by the increase of moisture(capacitance) and the reduction of scaling. Utilization of physiologic lipid mixture containing natural ceramides or synthetic pseudoceramide could lead to new forms of topical therapy for the dryness and dermatoses(e.g., psoriasis, atopic dermatitis and irritant dermatitis).

  • PDF

Recovery of Ammonium Salt from Nitrate-Containing Water by Iron Nanoparticles and Membrane Contactor

  • Hwang, Yu-Hoon;Kim, Do-Gun;Ahn, Yong-Tae;Moon, Chung-Man;Shin, Hang-Sik
    • Environmental Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.111-116
    • /
    • 2012
  • This study investigates the complete removal of nitrate and the recovery of valuable ammonium salt by the combination of nanoscale zero-valent iron (NZVI) and a membrane contactor system. The NZVI used for the experiments was prepared by chemical reduction without a stabilizing agent. The main end-product of nitrate reduction by NZVI was ammonia, and the solution pH was stably maintained around 10.5. Effective removal of ammonia was possible with the polytetrafluoroethylene membrane contactor system in all tested conditions. Among the various operation parameters including influent pH, concentration, temperature, and contact time, contact time and solution pH showed significant effects on the ammonia removal mechanism. Also, the osmotic distillation phenomena that deteriorate the mass transfer efficiency could be minimized by pre-heating the influent wastewater. The ammonia removal rate could be maximized by optimizing operation conditions and changing the membrane configuration. The combination of NZVI and the membrane contactor system could be a solution for nitrate removal and the recovery of valuable products.

Liquid Chromatography-Tandem Mass Spectrometry Analysis of Riboflavin in Beagle Dog Plasma for Pharmacokinetic Studies

  • Jeong, Hyeon Myeong;Shin, Beom Soo;Shin, Soyoung
    • Mass Spectrometry Letters
    • /
    • v.11 no.1
    • /
    • pp.10-14
    • /
    • 2020
  • Riboflavin is a water-soluble vitamin, which serves as a precursor to flavin mononucleotide and flavin adenine dinucleotide. This study aimed to develop a simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis for the quantification of riboflavin in the Beagle dog plasma. This method utilized simple protein precipitation with acetonitrile and 13C4, 15N2-riboflavin was used as an internal standard (IS). For chromatographic separation, a hydrophilic interaction liquid chromatography (HILIC) column was used with gradient elution. The mobile phase consisted of 0.1% (v/v) aqueous formic acid with 10 mM ammonium formate and acetonitrile with 0.1% (v/v) formic acid. Since riboflavin is an endogenous compound, 4% bovine serum albumin in phosphate buffered saline was used as a surrogate matrix to prepare the calibration curve. The quantification limit for riboflavin in the Beagle dog plasma was 5 ng/mL. The method was fully validated for its specificity, sensitivity, accuracy and precision, recovery, and stability according to the US FDA guidance. The developed LC-MS/MS method may be useful for the in vivo pharmacokinetic studies of riboflavin.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

A Simple Method for Determining Residual p-arsanilic Acid in Aquatic Products using EDTA-Assisted Solvent Extraction and LC-MRM

  • Min Kyeong Kwon;Ye Bin Shin;Young Min Kim;Jin Hwan Kim;Ji Seong Kim;Yong Seok Choi
    • Mass Spectrometry Letters
    • /
    • v.14 no.2
    • /
    • pp.36-41
    • /
    • 2023
  • A simple method was developed to determine residual p-arsanilic acid (ASA), an organo-arsenic compound used as a feed additive, in aquatic products (eel, halibut, and shrimp) using EDTA-assisted solvent extraction and LC-MRM. The method was successfully validated in terms of specificity, linearity (coefficient of determination ≥ 0.995), accuracy (recovery or R, 72.72-78.73%), precision (the relative standard deviation of R, 2.08-6.98%), and sensitivity (the lower limit of quantitation, 5 ppb) according to CODEX guidelines (CAC-GL 71-2009). The use of EDTA in the extraction solvent and water with a suitable pH modifier as the reconstitution solvent may be the key factors for successful results. This is the first method that can be used for monitoring residual ASA in aquatic products using LC-MRM and could contribute to establishing a better aquatic product safety management system.

Performance of adsorption heat pump with radial shape adsorber heat exchanger for air cooling (공냉식 방사형 열교환기를 갖는 흡착식 히트펌프의 성능)

  • Baek, N.C.;Yang, Y.S.;yoon, E.S.;Lee, J.K.;Joo, M.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.73-81
    • /
    • 1997
  • In this experimental study, the air cooling radial shape heat exchanger which influences on the COP and the cooling capacity by heat and mass transfer rate in the adsorbent bed was designed and applied to test its performance for adsorption heat pump(AHP). Zeolite-water was used for the adsorbent-adsorbat pair. As a result, the cooling COP and a cycle period of this adsorption heat pump are 0.28 and 2 hours, respectively, on the condition of none heat recovery from the adsorption reactor(absorber). The other results and recommendations are mainly related to improving the heat and mass transfer inside the absorber to reduce a cycle period.

  • PDF

Determination of 4-Nitrotoluene Exposure in Water, Soil and Sediment by Gas Chromatography- Mass Spectrometry (기체크로마토그래피/질량분석기에 의한 토양, 저질 및 수질시료 중 4-Nitrotoluene의 노출평가)

  • Jeon Hee Kyung;Choi Hae Yeon;Ryu Jae-Chun
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.2 s.49
    • /
    • pp.123-131
    • /
    • 2005
  • 본 연구는 GC/MS를 이용하여 수질, 토양 및 저질 시료 중의 4-Nitrotoluene(4-NT)을 분석하는 방법을 확립하고자 하였다. 4-NT은 수질 시료(100mL)에서 n-hexane으로 추출하였으며, 토양 및 저질 시료(10g)에서는 먼저 메탄올로 추출한 후 hexane으로 다시 추출하여 농축시켜 분석하였다. 수질 시료 중의 4-NT의 회수율은 $99.1\%$ 이상이였으며 토양에서의 회수율(recovery)은 약 $110\%$를 보였고 재현성 (relative standard deviation)은 $11.99\%$ 이하였다. 검정곡선은 상관계수$(R^2)$값이 수질과 토양 모두에서 0.994이상의 좋은 직선성을 보여주었다. 본 연구에서 채취한 수질 43개 지역, 토양 35개 지역 및 저질 11개 지역의 모든 시료에서 4-NT은 검출한계 이하로 나타났다. 이 분석방법은 환경 중에 미량으로 존재하는 4-NT의 분석과 모니터링에 유용하게 사용할 수 있는 적합한 방법이라 사료된다.

Study on the Ethanol Recovery Process using Dircet Contact Heat Exchange (고온의 기포접촉에 의한 에탄올 회수공정에 관한 연구)

  • Lee, Won-Young;Yeo, Sang-Do;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.176-180
    • /
    • 1995
  • Direct contact heat exchange (DCHE) method has been employed to investigate the separation of ethanol from dilute aqueous solutions. Bubbles at high temperature were dispersed into a continuous liquid phase, generating temperature gradient in air-liquid interface, which causes heat and mass transfer accordingly. The experiments were performed in the ranges of jet regime air flow. The air-water stripping coefficient increased $5{\sim}10,\;and\;1{\sim}1.5$ times as temperature and air flow rate increased, respectively. The recovery ratio based on the initial ethanol concentration reached into 80% at the air flow rate of 84.88 m/min. The initial ethanol concentration showed little effect on the stripping coefficient and the recovery ratio.

  • PDF

Characteristic recovery of active carbon waste treated by microwave (Microwave에 의한 정수장 폐활성탄의 복원 특성)

  • Lee, Bum-Suk;Kim, Taik-Nam;Kim, Jong-Ock
    • The Journal of Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.93-107
    • /
    • 2002
  • The active carbon waste which was used in water purification plant was investigated for the improvement of capillary after microwave treatment. The variation of surface area was measured with the various kinds and amounts of active carbon. The water vapor as the activator was verified to improve the capillary but it reacted with the water contained in waste active carbon. In contrast to the water vapor, the $CO_2$ gas improved the surface area about 10-20 % compared to as received one. The best results was observed at the intensity of 2.75 kw microwave. The more effective recovery of active carbon waste was observed at the microwave treatment compared to the rotary kiln treatment. However, the mass production is so difficult in the microwave process.

  • PDF