• 제목/요약/키워드: Mass flow-meter

검색결과 124건 처리시간 0.02초

기체 분리용 수팽윤성 분리막 제조. I. (Preparation of water-swollen-hydrogel membrane for gas separation. I.)

  • 박유인;이규호
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 추계 총회 및 학술발표회
    • /
    • pp.43-44
    • /
    • 1996
  • Water-swollen-hydrogel membranes for gas separation were prepared by dipcoating and thermal crosslinking of poly(vinylalcohol) (PVA) - poly(acrylacid) (PAA) blends on asymmetric porous polyetherimide(PEI) supporters. The polyetherimide supporters, prepared by phase inversion of polyetherimide solutions in N-methylpyrrolidone(NMP) (composition of PEI/NMP=25/75), had good heat and chemical resistane. The coating materials with different blending ratios of PVA/PAA(=90/10, 80/20, 70/30) were characterized with differential scanning calorimetry (DSC), infrared spectroscopy(IR) and the water swelling ratios. The permeabilities and the separation factors of carbon dioxide through these membranes were measured by a mass flow meter and gas chromatograph at different temperatures, respectively, under a vacuum mode of downstream.

  • PDF

와이어 전극과 평행판에서 발생되는 이온풍 특성 연구 (A Study on an Ion Wind Created by a Wire Electrode and Parallel Plates Assembly)

  • 안영철;황필재;이재근
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.318-323
    • /
    • 2004
  • When a strong electric field is applied between a sharply curved electrode and a blunt surface, the corona may result in a gas movement in the electrode gap which is directed toward the blunt surface. That is called the corona wind. It enhances heat and mass transfer between the surface and the surrounding gas. Moreover such enhancement causes no noise or vibration, which can be applied in complex, isolated geometries, and allows simple control of surface temperatures. This paper examines the relationship between the corona wind and the relative humidity. The facility consists of high voltage power supply thin tungsten wire, plate electrode, multimeter, microammeter and flow meter. Gas velocity is a linear function of voltage, relative humidity and is proportional to the square root of the current. The maximum velocities for the positive and negative corona discharge are 1.9 m/s (2.74 CMM/m), 1.5 m/s(2.15 CMM/m), respectively.

수평관내 이산화탄소의 증발 압력강하 (Evaporation pressure drop of $CO_2$ in a horizontal tube)

  • 이동건;손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.552-559
    • /
    • 2005
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor qualify, heat flux and saturation temperature. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations. the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

수평관내의 $CO_2$의 증발 열전달에 관한 연구 (Study on the Evaporation Heat transfer of $CO_2$ in a Horizontal tube)

  • 장승일;최선묵;김대희;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.240-241
    • /
    • 2005
  • The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 kg/$m^2s$, saturation temperature of 0$^{circ}C$ to 20$^{circ}C$, and heat flux of 10 to 30 kW/$m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

수평관내 이산화탄소의 증발 압력강하 (Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube)

  • 구학근;손창효
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF

PAG 오일이 $CO_2$ 증발열전달에 미치는 영향에 관한 실험적 연구 (Experimental Study on Effects of PAG Oil for $CO_2$ Evaporation Heat Transfer)

  • 이상재;김대훈;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.357-363
    • /
    • 2008
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a horizontal micro-fin tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($400{\sim}1200\;kg/m^2s$), heat fluxes($10{\sim}30\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$), and PAG oil concentration($0{\sim}5\;wt%$). The variation of the heat transfer coefficient was different in accordance with the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

내경 1.77 mm의 다중관식 가스냉각기내 CO2 전열 성능에 대한 실험적 연구 (Experimental Study on Heat Transfer Performance of CO2 in a Multi-Tube Type Gas Cooler of Inner Diameter Tube of 1.77 mm)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.439-444
    • /
    • 2008
  • The heat capacity and pressure drop of $CO_2$ and coolant in a multi-tube type gas cooler were investigated experimentally. The main components of the refrigerant loop are a receiver, a $CO_2$ compressor, a mass flow meter, an evaporator and a multi-tube type gas cooler as a test section. The mass flowrate of $CO_2$ and coolant were varied from 0.06 to 0.075 [kg/s], respectively and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The heat capacity of $CO_2$ in the test section is increased with the increment in mass flowrate of coolant, the cooling pressure and mass flowrate of $CO_2$. The pressure drop of $CO_2$ is decreased with the decrease in mass flowrate of coolant and $CO_2$, but decreased with increase in cooling pressure of $CO_2$. The heat capacity of $CO_2$ per unit heat transfer area of gas cooler is greatly high. Therefore, in case of the application of $CO_2$ at the multi-tube type gas cooler, it is expected to carry out the high-efficiency, high-performance and compactness of gas cooler.

역전 유동층을 이용한 관군 내에서의 슬러리아이스 생성에 관한 연구 (A Study on Formation of Slurry Ice by using the Reversing Flow in a Bundle of Tube)

  • 오철;최영규
    • 한국항해항만학회지
    • /
    • 제35권5호
    • /
    • pp.365-370
    • /
    • 2011
  • 최근 지구 온난화와 더불어 급격한 기후 변화 등으로 여름철 주간 냉방 수요가 급격히 증가하고 있다. 이에 따른 전력 수요량 또한 증가하고 있다. 이런 이유로 세계적으로 에너지 이용 효율 향상에 대한 관심이 높아지고 있고, 최근 국내 및 국외의 축냉시스템을 이용한 주간 전력 피크값을 최소화 하는 연구개발과 실제 적용 사례가 늘어나고 있다. 빙축열시스템의 경우 그 경제적 효과가 높아 그 관심이 높아지고 있는 추세이다. 축냉시스템은 주간 냉방에 사용하는 냉열을 야간에 만들어 탱크에 저장해 두었다가 그것을 낮에 이용함으로써, 갑작스런 부하 증가에 적절히 대응할 수 있는 등 여러 가지 장점을 갖고 있다. 본 실험에서는 슬러리아이스 생성을 위해 냉각표면에서 생성된 슬러리아이스를 분리시키기 위해 유체보다 밀도가 낮은 역전유동 물질을 삽입하여 역전 유동층을 형성하였으며, 역전유동층의 유동에 의해 관군으로 구성되어 있는 냉각튜브 표면에 빙부착이 심화되기 전에 얼음 입자를 분리시켜 수 내지 수십 미크론 단위의 슬러리아이스를 생성하도록 하였다.

마이크로핀관 증발기내 전열 성능에 미치는 냉동기유의 영향 (Effect of refrigeration lubricants on the heat transfer performance in the microfin tube evaporator)

  • 조금남;태상진
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.61-72
    • /
    • 1999
  • The present study experimentally investigated the effect of refrigeration lubricant on the heat transfer performance in the straight sections and U-bend of a microfin tube evaporator by using R-22/mineral oil and R-407C/POE oil. The apparatus consisted of test section with U-bend, preheater, condenser, oil injection and sampling devices, magnetic pump, mass flow meter etc. The experimental parameters were oil concentration of 0 to 5 wt%, inlet quality of 0.1 to 0.5, mass flux of 219 and $400kg/m^2s$ and heat flux of 10 and $20kW/m^2$. The effects of parameters on the heat transfer coefficients were large in the order of inlet quality, mass flux and heat flux as oil concentration got increased. As oil concentration was increased, heat transfer coefficients were continuously decreased for R-22 and increased by 3% up to the concentration of 1% and then decreased for R-407C under the condition of large inlet quality, and small mass flux and heat flux. But, the heat transfer coefficients were increased up to the concentration of 3% and then decreased for both R-22 and R-407C refrigerants under the opposite conditions. The variation of enhancement factors for R-407C was under 50% of that for R-22 and the variation with respect to the positions in the test section was small. The pressure drops were increased for both R-22 and R-407C refrigerants as oil concentration was increased. The pressure drops for R-407C were smaller by the maximum of 18% than those for R-22.

  • PDF

평활관에서 이산화탄소의 증발열전달 특성에 관한 실험연구 (Experimental Study on Characteristics of Evaporation Heat Transfer of CO2 in a Smooth Tube)

  • 이상재;최준영;이재헌;권영철
    • 에너지공학
    • /
    • 제16권4호
    • /
    • pp.181-186
    • /
    • 2007
  • 본 연구에서는 이산화탄소의 증발열전달 특성을 이해하기 위해 질량유속, 열유속 기리고 포화온도를 변화시키면서 이산화탄소의 증발 열전달계수와 압력강하를 측정하였다. 질량유속과 열유속은 기존의 실험범위보다 크게 확장하여 내경 7.75 mm, 길이 5.0 m의 수평관에서 실험하였다. 실험장치는 시험부, 전원공급기, 히터, 칠러, 기어펌프, 유량계, 계측시스템 등으로 구성되었다. 건도가 증가할수록 증발 열전달계수는 감소하였으며, 이산화탄소의 증발 열전달계수는 질량유속보다 열유속에 더 민감함을 확인하였다. 또한 주어진 열유속과 포화온도에 따라 증발 열전달계수의 급격한 감소가 다르게 관찰되었다. 압력강하는 질량유속 증가에 대해 선형적인 증가를 보였지만 열유속 증가에 대한 압력강하의 증가효과가 크지 않았다.