• Title/Summary/Keyword: Mass Measurement

Search Result 1,493, Processing Time 0.029 seconds

An experimental study of the time based mass flow controller for semiconductor industry (반도체용 시간식 질량유량계의 특성에 관한 연구)

  • Chang, Young-Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.55-58
    • /
    • 2008
  • The objective of the research is to design, manufacture and test a Mass Flow Controller(MFC) capable of measuring compressible fluid flows based on a "bucket and stop-watch"method. The basic principle is the measurement of time, where the time taken to fill and empty a bucket of known volume is measured. This method of flow measurement is a new concept when compared to a commercilized current mass flow controller. For the flow meter to be able to compete with established designs it not only must be comparable in cost and robustness, it must be very accurate and reliable as well. This device should be able to handle fluid flows in the range of 0.1ml/min to 10ml/min within an accuracy of ${\pm}$1%. A possible application for a device such as this is in electronics industry where arsenic gas is used in the production of silicon chips.

  • PDF

Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone (드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정)

  • Kim, Heesang;Park, Yonghe;Kim, Wooyoung;Eun, Heeram;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.14 no.2
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

Quantitative Analysis of Trace pp'-DDE in Corn Oil by Isotope Dilution Mass Spectrometry : Uncertainty Evaluations

  • 김병주;김달호;최종오;소헌영
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.8
    • /
    • pp.910-916
    • /
    • 1999
  • A current interest in chemistry concerns traceability of analytical measurements to the International System of Units (SI) and the proper estimation of their uncertainties in accordance with the internationally agreed guide provided by the International Organization for Standardization (ISO). Isotope dilution mass spectrometry (IDMS) is regarded as a primary method, which make the measurement results traceable to SI units without significant empirical correction factors. Our laboratory, as the national standards institute of Korea, participated in an intercomparison of environmental analysis, pp'-DDE in corn oil, which was organized by the CCQM under supervision of the CIPM to test feasibility of IDMS as a primary method for the trace analysis of organic compounds. In this report, we provide basic equations used for the calculation of the concentration of the analyte in a sample and a precise description of the processes for the evaluation of the uncertainties of the measurement results. Also, we report the experimental conditions adopted to improve the accuracy of the IDMS measurement. The principles contained in ??Guide to the Expression of Uncertainty in Measurement'' provided by ISO are followed for the uncertainty evaluation.

Development of Small Size Coriolis Mass Flowmeter (소형 코리올리 질량 유량계의 개발)

  • Lim Ki-Won;Ji Jueng-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

Study on Measurement Errors due to Attenuation in Plannar Image technique (평면 이미지 기법에서 감쇠로 인한 측정 오차에 대한 연구)

  • Jeon, J.Y.;Kim, D.J.;Koh, H.S.;Yoon, Y.B.
    • Journal of ILASS-Korea
    • /
    • v.7 no.3
    • /
    • pp.24-30
    • /
    • 2002
  • In the analysis of the mass distribution and SMD(Sauter Mean Diameter), planar laser imaging technique is a convenient and useful one when compared to the mechanical pattemator or PDPA (Phase Doppler Particle Analyzer). But recorded signals at cameras and intensity of laser are distorted by attenuation. Using experimental datum and assumptions, we study measurement errors due to attenuation in plannar image technique.

  • PDF

Investigation of Factors Related to Physical Health in the Old People : Focusing on sarcopenia and locomotive syndrome (노인의 신체건강 관련 요인 조사 : 근감소증과 운동기능저하증후군을 중심으로)

  • Hae-In Kim;Myung-Chul Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.2
    • /
    • pp.129-140
    • /
    • 2023
  • Purpose : This study was conducted to investigate and analyze the physical health of older Koreans with sarcopenia and locomotive syndrome and identify the related factors. Methods : In this study, the sarcopenia and locomotive syndrome evaluations were applied to 210 elderly people, and the sarcopenia group was 36, the locomotive syndrome group was 164, and the normal group was 10. After group selection, a physical health status survey was conducted. The physical health status was assessed via body composition analysis, physical characteristics survey including measurement of waist and calf circumference, investigation of diseases currently being diagnosed by a doctor, and frailty measurements. The collected data were statistically analyzed using one-way ANOVA, the Kruskal-Wallis test, and the Chi-square test. Results : There were significant differences between groups in all elements of physical characteristics including body mass index, waist circumference, and calf circumference. Among them, a consistent result was found that the normal group had the largest amount of muscle mass and the sarcopenia group had the least amount of muscle mass in the factors related to muscle mass. However, the factors relating to fat mass and obesity also showed significant differences between the groups, but the results were not consistent. Considering the group differences in current diseases, a significant difference was only detected for osteoporosis among 12 diseases. Moreover, those in the sarcopenia group had the highest rate of osteoporosis. And there was no significant difference between the groups in the total score of the frailty measurement, but there was a significant difference between the groups in the frailty measurement levels. Conclusion : This study on physical health status confirmed that muscle mass-related factors, osteoporosis, and frailty levels were significantly related to sarcopenia and locomotive syndrome.

Low Skeletal Muscle Mass and Clinical Outcomes in Chronic Obstructive Pulmonary Disease

  • Yong Jun Choi;Hye Jung Park;Jae Hwa Cho;Min Kwang Byun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.4
    • /
    • pp.272-283
    • /
    • 2023
  • Background: In patients with chronic obstructive pulmonary disease (COPD), decreased muscle mass is a frequently encountered comorbidity in clinical practice. However, the evaluation of muscle mass in patients with COPD in real-world practice is rare. Methods: We retrospectively reviewed the electronic medical records of all patients with COPD who underwent bioelectrical impedance analysis at least once between January 2011 and December 2021 in three hospitals. Then, we analyzed the performance rate of muscle mass measurement in the patients and the correlation between muscle mass, clinical parameters, and COPD prognosis. Results: Among the 24,502 patients with COPD, only 270 (1.1%) underwent muscle mass measurements. The total skeletal muscle mass index was significantly correlated with albumin, alanine transaminase, and creatinine to cystatin C ratio in patients with COPD (r=0.1614, p=0.011; r=0.2112, p=0.001; and r=0.3671, p=0.001, respectively). Acute exacerbation of COPD (AE COPD) was significantly correlated with muscle mass, especially the truncal skeletal muscle mass index (TSMI) in males (r=-0.196, p=0.007). In the multivariate analysis, TSMI and cystatin C were significant risk factors for AE COPD (hazard ratio, 0.200 [95% confidence interval, CI, 0.048 to 0.838] and 4.990 [95% CI, 1.070 to 23.278], respectively). Conclusion: Low muscle mass negatively affects the clinical outcomes in patients with COPD. Despite its clinical significance, muscle mass measurement is performed in a small proportion of patients with COPD. Therefore, protocols and guidelines for the screening of sarcopenia in patients with COPD should be established.

Validity of Bioelectrical Impedance Analysis(BIA) in Measurement of Human Body Composition (소아 체지방 평가를 위한 생체 저항분석법의 타당성 연구 : 이중 에너지 방사선 흡수법과의 비교)

  • Kim, Hyung-Suck;Kim, Su-Yung
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.696-700
    • /
    • 2005
  • Propose : Body composition by bioelectrical impedance analysis(BIA) is a very useful method of analysing body composition. BIA is non-invasive, inexpensive, nonhazaedous and reproducible technique. The aim of this study was to determine the level of agreement between body composition measurement by BIA and dual-energy X-ray absorptiometry(DEXA). Methods : Data was examined in 100 children(male 58; female 42), who visited Pusan National Hospital. Weight(kg) and height(cm) were measured, and body compositions were analyzed with fat mass, lean body mass, body fat percent by BIA and DEXA methods. Results : Comparison of the DEXA and BIA methods showed highly statistically significant correlations in measurement of human body composition(fat mass, lean body mass, body fat percent). Conclusion : BIA should be considered as the method of choice in measurement of human body composition, since it's non-invasive, reliable, rapid, nonhazaedous and inexpensive, using portable equipment.

Characterization of Modified Peptides by Tandem Mass Spectrometry

  • Chang, Yoon-Seok;Jang, Jung-Suk
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.849-854
    • /
    • 1995
  • A series of biologically active phosphopeptides were synthesized and their behavior in tandem mass spectrometry have been investigated. The structure identifications of other unusual peptides such as sulphated, glycosylated, lipoidal, and backbone modified peptides have been carried out. For all tested peptides, the structural modification could be determined directly by measurement of the absolute molecular weight in combination with collision-induced-dissociation in tandem mass spectrometry.

  • PDF

Characteristics of Quadrupole Mass Spectrometer for Partial Pressure Measurement in CO-$H_2$ Gas Mixture (CO와 $H_2$ 혼합기체에 대한 Quadrupole Mass Spectrometer의 감도 특성)

  • 신용현;홍승수;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.3
    • /
    • pp.314-318
    • /
    • 1993
  • Quadrupole mass spectrometer는 부분압 측정 및 잔류기체 분석에 널리 이용되고 있는 장비이다. CO, H2, Ar이 혼합되어 존재할 때 quadrupole mass spectrometer의 감도를 10-4∼10-8torr영역에서 측정하고 단일기체로 존재할 때의 감도와 비교하였다. 그 결과 일정한 부분압을 유지하고 있는 경우라도, 주위 분위기 기체 종류와 부위기 기체 압력에 따라 감도 별화가 심한 것을 알 수 있었다. 따라서 QMS를 부분압 측정이나 조성분석에 이용하기 위해서는 이에 대한 특성조사가 반드시 필요하다.

  • PDF