• 제목/요약/키워드: Mass Energy

검색결과 3,847건 처리시간 0.031초

Chemical Composition of the Size-resolved Particles in Buk-Ak Tunnel

  • Ma, Chang-Jin;Hwang, Kyung-Chul;Kang, Gong-Unn;Tohno, Susumu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제20권E2호
    • /
    • pp.53-59
    • /
    • 2004
  • The roadway tunnels in urban areas give rise to problems such as a localized air pollution. Here, we report the results of a case study of an urban roadway tunnel measurement. The size-resolved particle sampling was carried out with a two 2-stage filter pack samplers and an Andersen impactor sampler at the center of Buk-Ak tunnel in November 2001. Particle Induced X-ray Emission (PIXE) was applied to determine the elemental composition of size-resolved particles divided into soluble and insoluble fractions. The Thermal/Optical Reflectance (TOR$^{(R)}$) method was also employed in analyzing of elemental carbon (EC) and organic carbon (OC). Mass concentrations of fine (< 1.2 ${\mu}{\textrm}{m}$) and coarse (> 1.2 ${\mu}{\textrm}{m}$) particles are 165 and 48 $\mu\textrm{g}$ m$^{-3}$ , respectively. Total elemental mass concentration (the sum of insoluble coarse, soluble coarse, insoluble fine, and soluble fine) is found to be 24$\mu\textrm{g}$ m$^{-3}$ and comprises only 11 % of total particle mass concentration. The concentrations of EC, OC, and mass show the clear dependency on particle size with the maximum between 0.1 and 0.43 ${\mu}{\textrm}{m}$ aerodynamic diameters. Total carbon (sum of EC and OC) accounts for approximately 70% of mass concentration.n.

Methodological Study on Measurement of Hydrogen Abundance in Hydrogen Isotopes System by Low Resolution Mass Spectrometry

  • Lia, Jin-Ying;Shib, Lei;Hub, Shi-Lin
    • Mass Spectrometry Letters
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 2011
  • China's rapid economic growth has resulted in significant environmental side effects. Therefore, China has been interested in reducing her dependence on foreign oil and gas by developing technologies needed for hydrogen, in addition to her increasing energy mix of nuclear and renewable energy form, such as solar and wind power. There are three isotopes of hydrogen, i.e. protium (P or H), deuterium (D), and tritium (T). Both deuterium and tritium are important materials in nuclear fuel cycle industry. Tritium is one of the critical radioactive nuclides. Planning for and implementing contamination control as a part of normal operation and maintenance activities is an important function in any hydrogen facility, especially tritium facility. The development of hydrogen isotopes analysis is the key issues in this area. Mass spectrometry (MS) with medium (about 600) and high resolution (> 1,400) is commercially available; however, the routine analysis of hydrogen isotopes is done with low-resolution MS (< 200) in China. This paper summarizes the progress of MS measurement technology for hydrogen isotope abundance in China, focusing on our lab's research program and technical status. An analyzing method has been introduced for accurate measurement of tritium abundance in the H.D.T system by low resolution MAT-253 MS. The quotient of compression ratio coefficient is determined by building up equipment for laboratory-scale preparation of secondary standard gases and by considering the difference in sensitivity between hydrogen isotopes. The results show that the measured value is reproducible within the relative error range of 0.8% for gas samples of different tritium abundance.

The drivers and energetics of ionized gas outflows in powerful Type 2 AGN in the local Universe

  • Karouzos, Marios;Woo, Jong-Hak;Bae, Hyun-Jin
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.37.2-37.2
    • /
    • 2016
  • There exist scaling relations that link the mass of supermassive black holes with both the velocity dispersion and the mass of the central stellar cusp of their host galaxies. This implies that galaxies co-evolve with their central black holes, potentially through the feedback from actively accreting supermassive black holes (AGN). We use integral field spectroscopy data from the 8.2m Gemini-North telescope to investigate ionized gas outflows in luminous local (z<0.1) Type 2 AGN. Our sample of 6 galaxies was selected based on their [OIII] dust-corrected luminosity (>$10^{42}erg/s$) and signatures of outflows in the [OIII] line profile of their SDSS spectra. These are arguably the best candidates to explore AGN feedback in action since they are < 1% of a large local type 2 AGN SDSS sample selected based on their [OIII] kinematics. Expanding on previously reported results concerning the kinematic decomposition and size determination of these outflows, here we report their photoionization properties and energetics. We find strong evidence that connect the extreme kinematics of the ionized gas with AGN photoionization. The kinematic component related to the AGN-driven outflow is clearly separated from other kinematic components, such as gravitation- or stellar-driven motions, on the velocity and velocity dispersion diagram. Our spatially resolved kinematic analysis reveals that up to 90% of the mass and kinetic energy of the outflow is contained within the central kiloparcec of the galaxy. The total mass and kinetic energy of the outflow correlate well with the AGN bolometric luminosity, resulting in energy conversion efficiencies between 0.01% and 1%. Intriguingly, we detect ubiquitous signs of ongoing circumnuclear star formation. Their small size, the centrally contained mass and energy, and the universally detected circumnuclear star formation cast doubts on the potency of these AGN-driven outflows as agents of negative feedback.

  • PDF

녹색기업의 사업활동 전 과정에 대한 환경성 평가 -2. 물질수지 및 환경개선 (Life Cycle Assessment for the Business Activities of Green Company -2. Mass Balance and Environmental Improvement)

  • 신춘환;박도현
    • 한국환경과학회지
    • /
    • 제22권4호
    • /
    • pp.425-433
    • /
    • 2013
  • A mass balance of process was calculated by using the analysis of basic unit and environmental assessment of all the processes of Busan fashion color industry cooperative that operates a combined heat and power plant and a bio treatment plant. The mass balance for the combined heat and power plant was done, based on boiler and water treatment processes while each unit reactor was used for the bio treatment plant. From the results above, a resource recycle network, a treatment flowchart for food waste water/wastewater treatment and a carbon reduction program were established.

Dialysis with ultrafiltration through countercurrently parallel-flow membrane modules

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • 제4권3호
    • /
    • pp.191-202
    • /
    • 2013
  • The application of ultrafiltration operation to the dialysis in countercurrently parallel-flow rectangular membrane modules was investigated. The assumption of uniform ultrafiltration flux was made for operation with slight concentration polarization and declination of transmembrane pressure. Considerable improvement in mass transfer is achievable if the operation of ultrafiltration is applied, especially for the system with low mass transfer coefficient. The enhancement in separation efficiency is significantly increased with increasing ultrafiltration flux, as well as with increasing the volumetric flow rates. Furthermore, increasing the volumetric flow rate in retentate phase is more beneficial to mass transfer than increasing in dialysate phase.

Complete Simultaneous Analysis of Uranium Isotopes in NUSIMEP-7 Microparticles Using SEM-TIMS

  • Park, Jong-Ho;Jeong, Kahee
    • Mass Spectrometry Letters
    • /
    • 제7권3호
    • /
    • pp.64-68
    • /
    • 2016
  • Scanning electron microscopy combined with thermal ionization mass spectrometry (SEM-TIMS) was used to determine the precise isotope ratios of ultra-trace levels of uranium contained in individual microparticles. An advanced multiple ion counter system consisting of three secondary ion multipliers and two compact discrete dynodes was used for complete simultaneous ion detection. For verification purposes, using TIMS with complete simultaneous measurement, isotopes were analyzed in 5 pg of uranium of a certified reference material. A microprobe in the SEM was used to transfer individual particles from a NUSIMEP-7 sample to TIMS filaments, which were then subjected to SEM-TIMS and complete simultaneous measurement. The excellent agreement in the resulting uranium isotope ratios with the certified NUSIMEP-7 values shows the validity of SEM-TIMS with complete simultaneous measurement for the analysis of uranium isotopes in individual particles. Further experimental study required for investigation of simultaneous measurement using the advanced multiple ion counter system is presented.

Giant Thyroid Mass Excision Using Energy Device and Pectoralis Major Myocutaneous Flap Reconstruction

  • Song, Min Seok;Lee, Sang Joon;Woo, Seung Hoon
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.115-119
    • /
    • 2021
  • A giant thyroid mass can be associated with severe compressive symptoms, requiring surgery for treatment. This paper reports the case of an 82-year-old man who presented with a giant thyroid mass that was suspected of being a metastatic papillary thyroid carcinoma on fine-needle aspiration cytology. A harmonic scalpel was used to excise the giant thyroid mass. A pectoralis major myocutaneous flap was used for reconstruction. The histopathology assessment confirmed the metastases in the lymph node and papillary thyroid carcinoma in the resected gland.

Uranium Particle Identification with SEM-EDX for Isotopic Analysis by Secondary Ion Mass Spectrometry

  • Esaka, Fumitaka;Magara, Masaaki
    • Mass Spectrometry Letters
    • /
    • 제7권2호
    • /
    • pp.41-44
    • /
    • 2016
  • Secondary ion mass spectrometry (SIMS) is a promising tool to measure isotope ratios of individual uranium particles in environmental samples for nuclear safeguards. However, the analysis requires prior identification of a small number of uranium particles that coexist with a large number of other particles without uranium. In the present study, this identification was performed by scanning electron microscopy - energy dispersive X-ray analysis with automated particle search mode. The analytical results for an environmental sample taken at a nuclear facility indicated that the observation of backscattered electron images with × 1000 magnification was appropriate to efficiently identify uranium particles. Lower magnification (less than × 500) made it difficult to detect smaller particles of approximately 1 μm diameter. After identification, each particle was manipulated and transferred for subsequent isotope ratio analysis by SIMS. Consequently, the isotope ratios of individual uranium particles were successfully determined without any molecular ion interference. It was demonstrated that the proposed technique provides a powerful tool to measure individual particles not only for nuclear safeguards but also for environmental sciences.

CO2 냉매용 전자팽창밸브의 해석 및 평가 (Analysis and Performance Test of an Electronic Expansion Valve for CO2)

  • 김욱중;윤석호;홍용주;김정엽;강신일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1491-1496
    • /
    • 2009
  • Fluid flow and structural analyses of an electronic expansion valve (EEV) using CO2 as a working refrigerant are carried out to estimate the mass flow rate and maximum stress. An engineering sample EEV that the orifice diameter is 1.8 mm was fabricated. The mass flow rates were measured at various EEV inlet temperatures and pressures for several EEV openings using experimental heat pump system. The sample EEV has over 35 MPa burst pressure and the maximum mass flow rate of CO2 through the EEV increased to 100 g/s at full opening condition.

  • PDF

흡음재 및 제진재의 최적배치를 이용한 구조-음향 연성계의 소음제어 (Sound Control of Structural-acoustic Coupling System Using Optimum Layout of Absorbing Material and Damping Material)

  • 김동영;홍도관;안찬우
    • 한국소음진동공학회논문집
    • /
    • 제15권2호
    • /
    • pp.161-168
    • /
    • 2005
  • The absorbing material is mostly used to changing the acoustic energy to the heat energy in the passive control, and that consists of the porous media. That controls an air borne noise while the stiffened plates, damping material and additional mass control a structure borne noise. The additional mass can decrease the sound by mass effect and shift of natural frequency, and damping material can decrease the sound by damping effect. The passive acoustic control using these kinds of control materials has an advantage that is possible to control the acoustic in the wide frequency band and the whole space at a price as compared with the active control using the various electronic circuit and actuator. But the space efficiency decreased and the control ability isn't up to the active control. So it is necessary to maximize the control ability in the specific frequency to raise the capacity of passive control minimizing the diminution of space efficiency such an active control. Therefore, the characteristics of control materials and the optimum layout of control materials that attached to the boundary of structure-acoustic coupled cavity were studied using sequential optimization on this study.