• 제목/요약/키워드: Mass Efficiency

검색결과 1,889건 처리시간 0.025초

2차원 혼 타 단면의 간극유동 특성에 대한 연구 (Characteristics of Gap Flow of a 2-Dimensional Horn-Type Rudder Section)

  • 최정은;정석호
    • 대한조선학회논문집
    • /
    • 제44권2호
    • /
    • pp.101-110
    • /
    • 2007
  • Recently, rudder erosion due to cavitation frequently has occurred at large high speed container carriers. Especially, in the case of a horn-type rudder, the rudder erosion is severe around a gap. The gap-flow characteristics are investigated through a computational method to understand the effects of a gap on the cavitation and rudder efficiency. A viscous flow theory utilizing a cavitation model is applied to calculate the flow around idealized 2-dimensional rudder sections in a full scale. The effects of gap clearance and flow-control projection are also investigated. From the computational results, the mass flow rate through a gap is found to be one of the important parameters to affect the cavitation and rudder efficiency.

극저온 냉동기용 냉매압축기의 개발 (Development of Neon Compressor for Reverse Brayton Cryocooler)

  • 김승우;박기철;이기호;김경수;김동권
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.237-243
    • /
    • 2002
  • A centrifugal compressor of 50HP for reverse brayton cryocooler using neon as a coolent has been developed. It has relatively low total-to-total pressure ratio but mass flow rate is very small and the voting gas, neon, has greater specific heat ratio than air. It was essential to have very high rotational speed of 100,000 RPM. The efficiency of compressor has great effects on overall system and the COP of cryocooler. To meet the design requirement of the compressor efficiency and to minimized the required rotational speed, highly efficiency impeller having low specific speed was designed. To maintain the overall system efficient high, gas bearing of bump type and high speed permanent magnet synchronus motor was developed and adopted. In this paper, design and performance prediction results of the compressor impeller is presented.

  • PDF

단기통 4행정 디젤기관의 흡배기과정 시뮬레이션 연구 (Numerical simulation for the gas exchange process of 4-cycle single cylinder diesel engine)

  • 이재순;이재규
    • 오토저널
    • /
    • 제12권3호
    • /
    • pp.30-40
    • /
    • 1990
  • The computer program for the prediction of the volumetric efficiency of 4-cycle single cylinder diesel engine was developed using the characteristic method which considers the effects of friction, heat transfer and specific heat. The results of calculation by this program are as follows; 1. The back flowing was arised at the beginning and the closing stage of inlet valve, and the back flowing mass and velocity decrease as the engine speed increases. 2. The volumetric efficiency varies with the engine speed and the length of inlet manifold. There was an optimum length of inlet manifold for each specified engine speed. 3. The pressure fluctuation and friction effect in the inlet manifold became very important factors for the determination of the volumetric efficiency.

  • PDF

흡착관/열탈착 GC/MS 방법에 의한 모사시료 중의 미량 페놀 분석에 관한 평가 (Evaluation of the Measurement of Trace Phenols by Adsorption/Thermal Desorption/Gas Chromatography/Mass Spectrometry (ATD/GC/MS) in Artificial Air)

  • 허귀석;이재환;황승만;정필갑;유연미;김정우;이대우
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.127-137
    • /
    • 2002
  • Phenolic compounds in air are toxic even at their low concentrations. We had evaluated a total of five phenolic compounds (Phenol, o-Cresol, m-Cresol, 2-Nitrophenol and 4-Chloro-3-methylphenol) in artificial air using a combination of ATD/GC/MS. To compare the adsorption efficiency of these phenolic compounds, three adsorbents (Tenax TA, Carbotrap and Carbopack B) were tested. Tenax TA adsorbent was most effective of all the adsorbents used for the efficiency test. Five phenolic compounds were found to be very stable on adsorbent tubes for 4 days at room temperature. Detection limit of five phenolic compounds ranged from 0.05 to 0.08 ppb (when assumed to collect 10 L air). The calibration curve was linear over the range of 22∼ 164 ng. The reproducibility was less than 4%. Sampling of duplicate pairs (DPs) was made to demonstrate duplicate precision and sampling efficiency.

온수추출과정의 열유동 특성에 관한 연구 (A Study on Heat Flow Characteristics during Hot Water Extraction Process)

  • 장영근;박정원
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.549-556
    • /
    • 2001
  • Heat flow characteristics during hot water extraction process was studied experimentally. Data were taken at various outlet port type for the fixed inlet port type, inlet-outlet temperature differences and mass flow rates. In this study, the temperature distribution in a storage tank and an outlet temperature were measured to predict a flow pattern in the storage tank, and a hot water extraction efficiency was analysed with respect to the variables dominating a extraction process. Experimental results show that the extraction efficiency is high in a low flow rate in case of using modified distributor I(MDI) as a outlet port type.

  • PDF

저가.고효율 단결정 실리콘 태양전지의 제조 (Fabrication of Low cost, High Efficiency Single Crystal Silicon Solar Cells)

  • 이규정;김인식;남효진;박철
    • 전자공학회논문지A
    • /
    • 제31A권7호
    • /
    • pp.102-109
    • /
    • 1994
  • Low cost high efficiency single crystal silicon solar cells for terrestrial applications have been fabricated by using inexpensive materials such as solar grade silicon wafer and pastes, and mass production processes such as screen printing and spray. Under 100 mW/cm$^2$ (AM 1.5) and $25^{\circ}C$ conditions conversion efficiency of 16.48% was obtained by anon fire-thru process and 15.55% by fire-thru process.

  • PDF

혼합 개선을 위한 Y-채널 마이크로 믹서의 최적설계 (Optimum Design of a Y-channel Microcmixer for Enhanced Mixing)

  • 신용수;최형일;이동호;이도형
    • 대한기계학회논문집A
    • /
    • 제30권3호
    • /
    • pp.302-309
    • /
    • 2006
  • Effective mixing plays a crucial role in microfluidics for biochemical applications. Owing to the small device scale and its entailing the low Reynolds number, the mixing in microchannels proceeds very slowly. In this work, we optimize the configuration of obstacles in the Y-channel mixer in order to attain maximum mixing efficiency. Before the optimum design, mixing characteristics are investigated using unstructured grid CFD method. Then, the analysis method is employed to construct the approximate analysis model to be used in the optimization procedure. The main optimization tool in the present work is sequential quadratic programming method. Using this approximate optimization procedure, we may obtain the optimum layout of obstacles in the Y-channel mixer in an efficient manner, which gives the maximum mixing efficiency.

A Classification-Based Virtual Machine Placement Algorithm in Mobile Cloud Computing

  • Tang, Yuli;Hu, Yao;Zhang, Lianming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권5호
    • /
    • pp.1998-2014
    • /
    • 2016
  • In recent years, cloud computing services based on smart phones and other mobile terminals have been a rapid development. Cloud computing has the advantages of mass storage capacity and high-speed computing power, and it can meet the needs of different types of users, and under the background, mobile cloud computing (MCC) is now booming. In this paper, we have put forward a new classification-based virtual machine placement (CBVMP) algorithm for MCC, and it aims at improving the efficiency of virtual machine (VM) allocation and the disequilibrium utilization of underlying physical resources in large cloud data center. By simulation experiments based on CloudSim cloud platform, the experimental results show that the new algorithm can improve the efficiency of the VM placement and the utilization rate of underlying physical resources.

상향류식 고정생물막조를 이용한 오염소하천 정화에 있어서 유출수 농도 예측 (Prediction of Effluent Concentration for Contaminated Stream Purification using UFBR)

  • 박영식;문정현;안갑환
    • 한국습지학회지
    • /
    • 제4권1호
    • /
    • pp.87-95
    • /
    • 2002
  • The objective of this study is to treat contaminated stream by using a UFBR(upflow fixed biofilm reactor) packed with waste-concrete media. This system was tested from June 1999 to January 2000. Over $20.0^{\circ}C$, $COD_{cr}$ removal efficiency did not affected with organic loading rate while, $COD_{cr}$ removal efficiency decreased about 7% with decrease of temperature from $27.0^{\circ}C$ to $8.7^{\circ}C$. Under $16^{\circ}C$, TKN removal efficiency was affected with TKN loading rate. The proposed model apply to mass balance equation of fixed biofilm reactor for predicting effluent was well satisfied with measured value($R^2=0.94$).

  • PDF

Heat Transfer Characteristics in a Cylindrical Duct Packed with Solid Spheres

  • Lee, Seung-Hyuk;Kang, Kwan-Gu;Kim, Sung-Chan;Ryou, Hong-Sun;Noh, Dong-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.11-21
    • /
    • 2005
  • The present paper investigates the heat transfer characteristics in a cylinder packed with porous medium of solid spheres for various parameters such as mass flow rate, sphere diameter, length of the porous medium, and gas temperatures. Pressures and temperatures at the inlet and outlet regions were measured by using static pressure gages and R-type thermocouples. The modified relationship based on the Ergun equation is suggested for the estimation of pressure drops. In addition, the useful empirical correlation for thermal efficiency is obtained in the current study. Thermal efficiency is expressed in terms of non-dimensional time, sphere diameter, porosity, and pressure drops. It is also found that the pressure drop through the cylinder becomes larger as the gas temperature does higher at the inlet region, whereas it substantially decreases when the inlet flow rate decreases.