• Title/Summary/Keyword: Masonry building

Search Result 197, Processing Time 0.024 seconds

A Study on the Curved Form Generation Methodology of the Brick Architecture by Stretcher Bond - Focused on the Parametric Design Process - (길이쌓기에 따른 벽돌건축의 곡면형태 생성방법에 관한 연구 - 파라메트릭 디자인 프로세스를 중심으로 -)

  • Cho, Heayon;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.6
    • /
    • pp.163-171
    • /
    • 2017
  • Brick is not only aesthetically beautiful and emotional material, but also eco-friendly and good building commodity for human health. Nonetheless, the use of brick has declined, due to the difficulty of building high-rise buildings and the limitation of the free form implementation. However, modern society is increasingly interested in environmentally friendly finishing materials for solving environmental problems. From this point of view, the brick architecture is being reexamined as a material to improve the living environment and to provide comfort without destroying nature. In addition, the development of digital technology enables the implementation of various types of masonry method and curved forms. Parametric design is one of the ways to realize the curved forms and various architectural expressions for brick architecture. In this background, the purpose of this study is to develop algorithms that can easily generate curved brick walls through parametric design, enable various pattern designs, and respond to real-time feedback. The details of the study are as follows. First of all, we examine organic architecture, the trend of brick architecture, and the concept of parametric design. Secondly, In order to generate curved surface with complex curvature, major planning factors affecting form generation are examined. Finally, we develop a parametric design method that consists of generating a curved surface for brick arrangement, implementing a parametric algorithm, and generating a curved form using bricks. Consequentially, we propose an algorithm that can maximize the use of ready-made bricks without using cut bricks to design curved walls and present efficient and economical design alternatives.

Cumulative damage in RC frame buildings - The 2017 Mexico earthquake case

  • Leonardo M. Massone;Diego Aceituno;Julian Carrillo
    • Advances in Computational Design
    • /
    • v.8 no.1
    • /
    • pp.13-36
    • /
    • 2023
  • The Puebla-Morelos Earthquake (Mw 7.1) occurred in Mexico in 2017 causing 44 buildings to collapse in Mexico City. This work evaluates the non-linear response of a 6-story reinforced concrete (RC) frame prototype model with masonry infill walls on upper floors. The prototype model was designed using provisions prescribed before 1985 and was subjected to seismic excitations recorded during the earthquakes of 1985 and 2017 in different places in Mexico City. The building response was assessed through a damage index (DI) that considers low-cycle fatigue of the steel reinforcement in columns of the first floor, where the steel was modeled including buckling as was observed in cases after the 2017 earthquake. Isocurves were generated with 72 seismic records in Mexico City representing the level of iso-demand on the structure. These isocurves were compared with the location of 16 collapsed (first-floor column failure) building cases consistent with the prototype model. The isocurves for a value greater than 1 demarcate the location where fatigue failure was expected, which is consistent with the location of 2 of the 16 cases studied. However, a slight increase in axial load (5%) or decrease in column cross-section (5%) had a significant detrimental effect on the cumulated damage, increasing the intensity of the isocurves and achieving congruence with 9 of the 16 cases, and having the other 7 cases less than 2 km away. Including column special detailing (tight stirrup spacing and confined concrete) was the variable with the greatest impact to control the cumulated damage, which was consistent with the absence of severe damage in buildings built in the 70s and 80s.

Model Tests for the Damage Assessment of Adjacent Buildings in Urban Excavation (흙막이굴착에 따른 인접건물의 손상평가에 대한 모형실험연구)

  • Kim, Hak-Moon;Hwang, Eui-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.121-131
    • /
    • 2007
  • This study is to investigate the damage assessment of adjacent structures due to excavation in urban environment. Model tests were carried out for 2 story masonry building and frame structures in various shapes and locations. The damage level of adjacent structures were very differently estimated in accordance with the shape ratio (L/h) of structures, construction stages, and various locations. Therefore the most weak part (bay) of structure must be heavily instrumented and monitored in more details at early stage of constructions. The progressive crack development mechanism at various construction stages was revealed through model tests and crack size indicated more conservative side of damage level on the damage level graph.

Influence of exterior joint effect on the inter-story pounding interaction of structures

  • Favvata, Maria J.;Karayannis, Chris G.;Liolios, Asterios A.
    • Structural Engineering and Mechanics
    • /
    • v.33 no.2
    • /
    • pp.113-136
    • /
    • 2009
  • The seismic induced interaction between multistory structures with unequal story heights (inter-story pounding) is studied taking into account the local response of the exterior beam-column joints. Although several parameters that influence the structural pounding have been studied sofar, the role of the joints local inelastic behaviour has not been yet investigated in the literature as key parameter for the pounding problem. Moreover, the influence of the infill panels as an additional parameter for the local damage effect of the joints on the inter-story pounding phenomenon is examined. Thirty six interaction cases between a multistory frame structure and an adjacent shorter and stiffer structure are studied for two different seismic excitations. The results are focused: (a) on the local response of the critical external column of the multistory structure that suffers the hit from the slab of the adjacent shorter structure, and (b) on the local response of the exterior beam-column joints of the multistory structure. Results of this investigation demonstrate that the possible local inelastic response of the exterior joints may be in some cases beneficial for the seismic behaviour of the critical column that suffers the impact. However, in all the examined cases the developing demands for deformation of the exterior joints are substantially increased and severe damages can be observed due to the pounding effect. The presence of the masonry infill panels has also been proved as an important parameter for the response of the exterior beam-column joints and thus for the safety of the building. Nevertheless, in all the examined inter-story pounding cases the presence of the infills was not enough for the total amelioration of the excessive demands for shear and ductility of the column that suffers the impact.

Case Study on the Characteristics of Hanok Hotel (한옥호텔의 배치 및 공간특성에 관한 사례조사)

  • Kim, Sunyoung;Hwang, Yeon-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.169-177
    • /
    • 2014
  • The purpose of this study is to analyze the design characteristics of Hanok hotel. This study was approached by using theoretical investigation and a field survey. The field survey analyzed the current situations by conducting the master plan layout, architecture and interior design of the Hanok hotel. The field survey was tested by examining four different Hanok hotels from February 2014 to July 2014. After all, the results were analyzed based on given categories. The results of this research can be summarized as following. First, the characteristic of the master plan layout in Hanok hotel was appeared as "ㄷ" and "ㅡ" shapes. Those layouts were based on the spatial and the functional aspects of Hanok hotel facilities. Second, three different structural methods such as the korean traditional wooden structure, concrete, and masonry method were used in Hanok hotel construction to deliver the traditional architecture aspects while considering the functionality and convenience of the building. Third, most of Hanok hotels had the limited furniture range. The consideration of using several types of traditional furniture in different rates of the guest rooms help to increase the service quality and customer's satisfaction. Fourth, there were no diversity of using materials and colors in Hanok hotels that only few of them were used to express the traditional look. Fifth, the local characteristics were found in several Hanok hotels. To reflect the local characteristics in Hanok hotel is to construct a suitable environment to fit in nature and also it is easily to convey the local culture to others.

Prevention of Human injury and Countermeasure of evacuation about Fire of Nursing Homes by Conversion of existing buildings - Focused on rural areas in Gwangju and Jeonnam - (기존 건축물을 용도변경한 노인의료복지시설의 화재 인명피해 예방과 피난 대책 -광주·전남 농촌지역을 중심으로-)

  • Kim, Hyun-Tae;Kim, Won-Jin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.27-36
    • /
    • 2018
  • At present, the elderly population in Korea is 14% of the total population and then We has entered an the society of advanced age. Along with this, elderly people with dementia and palsy are also increasing. The demand for elderly nursing homes for elderly people with severe diseases such as dementia and stroke is also increasing, and the existing buildings are being secured by Conversion of existing buildings. However, it is difficult to evacuate and fire due to the out of date of buildings by Conversion of existing buildings. For example, there is a fire in the Indukukwon, Pohang City and Hyosung Geriatric Hospital, Jangseong in Korea, which have changed the use of existing buildings. Many elderly people died in a night fire. It was because of the sandwich panel walls and PVC flooring material produced toxic gas instantly. In this study, we investigated the nursing home that changing the use and established fire prevention of human injury and countermeasure of evacuation. First, the sandwich panels which leading to deaths due to the toxic gas were installed in most nursing home. We recommend the RC, the masonry wall, and the glass fiber panel instead of the sandwich panels, In addition, the PVC flooring is most used in nursing home, the flooring material is considered such as the building stones, the tile, and the yellow soil closing instead of the PVC flooring. Second, we investigated the installation status of fire fighting equipment. As a result, the automatic-emergency open&shut equipment, the smoke ventilator and the evacuation slide were rarely installed. In order to secure the golden time in case of fire and to prevent the asphyxia caused by the toxic gas, the law should be amended to install the equipment.

A Study on Current Situation of Rural Community Facilities Applied Universal Design (마을회관의 유니버설디자인 현황에 관한 연구)

  • Lee, Eul-Gyu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.1
    • /
    • pp.113-120
    • /
    • 2015
  • In recent years, the population composition of rural area is changing due to the decreasing population growth of the aged with disability and people returning to farming. Since 1970's the rural community facilities have been spreaded out across most rural villages. Although the rural community facilities are the most widely used facilities, the existing facilities are need to be new built or remodeled according to demographic changes, usage of facilities, and environmental condition. Given this reality, the rural community facilities such as village assembly hall and nursing home for senior citizen are not only used for daily life place but also used like co-residence having meals and sleeping together. Therefore the rural community facilities have the potential to become welfare service space for rural elderly people. This research focuses on the current situation of universal design applied community facilities. According to the research, most of the village community facilities were built in the 1990s and 82% of the buildings were more than 15 years old. Furthermore, 45% of the village community facilities more than 15 years old most have a ground floor in masonry structure. The area of the building is 65% less than $100m^2$. The width of the access entrance, the height of the sink, gas safety valve and so forth were relatively well designed. However, the handrail of the entrance, space in front of the toilet bowl, the height difference between the entrance and floor, the installation of the width of the ramp and stair handrail was relatively incomplete. Village community facilities to be built in the future should be universal design fundamentally.

Seismic vulnerability assessment of a historical building in Tunisia

  • El-Borgi, S.;Choura, S.;Neifar, M.;Smaoui, H.;Majdoub, M.S.;Cherif, D.
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.209-220
    • /
    • 2008
  • A methodology for the seismic vulnerability assessment of historical monuments is presented in this paper. The ongoing work has been conducted in Tunisia within the framework of the FP6 European Union project (WIND-CHIME) on the use of appropriate modern seismic protective systems in the conservation of Mediterranean historical buildings in earthquake-prone areas. The case study is the five-century-old Zaouia of Sidi Kassem Djilizi, located downtown Tunis, the capital of Tunisia. Ambient vibration tests were conducted on the case study using a number of force-balance accelerometers placed at selected locations. The Enhanced Frequency Domain Decomposition (EFDD) technique was applied to extract the dynamic characteristics of the monument. A 3-D finite element model was developed and updated to obtain reasonable correlation between experimental and numerical modal properties. The set of parameters selected for the updating consists of the modulus of elasticity in each wall element of the finite element model. Seismic vulnerability assessment of the case study was carried out via three-dimensional time-history dynamic analyses of the structure. Dynamic stresses were computed and damage was evaluated according to a masonry specific plane failure criterion. Statistics on the occurrence, location and type of failure provide a general view for the probable damage level and mode. Results indicate a high vulnerability that confirms the need for intervention and retrofit.

A Study on the Adaptive Reuse Techniques through the History of Buildings in the Historic Urban Area - Focused on the Deep and Narrow Lots of Nammun-ro 2Ga, Cheongju - (역사적 도심 내 건축물의 이력을 통해 본 재생기법에 관한 연구 -청주시 남문로 2가동의 세장형 필지를 대상으로-)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • This study is intended to derive the adaptive reuse techniques through the history and aspects of new construction, extension, repair, and other works, limited to the deep and narrow lots facing Seongan-gil and Nammun-gil in Nammun-ro 2 ga of Cheongju, the historic urban area. The results are as follows. 1) In the case of newly built reinforced concrete buildings, the central part of the top floor of the residence or all floors are opened to the open space(void) to facilitate lighting and ventilation. This is developed as a convection phenomenon due to the temperature difference from the slits between buildings, which affects the entire air flow of the block. 2) The buildings of extension and repair are composed of two-story masonry or steel frame, both the front store facing the road and the house on the back, but it looks like one because it is in contact with each other. If only a small gap between the front and rear buildings is restored to an external space or a space equipped with sun light, a small breath can be provided in lighting and ventilation. 3) The existing two-story wooden stores and houses have lost their external space due to repairs. With minimal intervention to restore the small courtyard, slits, and space under the eaves, it will not only improve lighting and ventilation, but also create a unique appearance as a segment of the elongated store.

A Study on the Deteriorations Mechanism of Timeworn Buildings in Seoul (대도시 지역의 노후 건축물의 노후 성상에 관한 연구)

  • Kwon, Ki-Hyuk;Lee, Kyoung-Yong;Yang, Hee-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.87-95
    • /
    • 2002
  • Because of the gravitation of population toward large cities, a number of buildings have been constructed since 1970's. They have been rapidly deteriorated as time passed by. Therefore the purpose of this paper is to present basic data on private buildings managed by the Seoul Metropolitan Government and to analyse deterioration factors of them as well as interrelation. And then, the results of this paper can be used to establish the policy of managing timeworn buildings. Through this study timeworn masonry buildings occupy the major part of timeworn buildings, which have almost structural instability, especially individual residence. Both structure type and building type have an interrelation with the deterioration grade. The structure grade have an interrelation with occupancy class more than structure type.