• Title/Summary/Keyword: Masking ability

Search Result 35, Processing Time 0.021 seconds

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.

OPACITY AND MASHING EFFECT OF THE OPAQUE SHADE COMPOSITE RESINS (Opaque shade 복합레진의 opacity와 배경 색상 차단 능력의 평가)

  • Park, Su-Jung;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.356-364
    • /
    • 2007
  • The purpose of this study was to assess the background color-interceptive ability ana opacity of opaque shade composites (Universal composite, Filtek Z350, Charisma, Clearfil ST, Palpaque Estelite, Esthet-X, and Metafil Flo). Twenty four background specimens (diameter 5.5 mm, thickness 3.0 mm) with Root dentin Mustard (Bisco, Schaumburg, IL, USA) were made. The CIE $L^*a^*b^*$ value of background specimens was measured by a spectrophotometer (Spectrolino, GretagMacbeth, Regensdorf, Switzerland). Three specimens in every group were filled on the background specimens. The surface color of samples was measured by a spectrophotometer in 3.0 mm and every thickness to 0.5 mm while grinding. The color difference in the background color along with 3.0 mm specimen gauged the masking effect in each thickness while grinding and polishing. The opacity was calculated in 1 mm thick specimens. The opacity was in the decreasing order of Clearfil ST, Metafil Flo, Filtek Z350, Palpaque Estelite, Universal composite, Charisma, and Esthet-X (p < 0.05). As the thickness get reduced, $L^*$ value showed decreasing, $a^*$ increasing tendency. The surface color difference between pair of the 3.0 mm thick specimen and after grinding in same opaque resin was above 3.3 except Clearfil ST and Metafil Flo. The color difference (${\Delta}E^*$) between pair of background specimen and opaque resin built-up specimen showed more than 10.0 regardless kinds and thickness. The variance in opacity characteristics and color of the opaque composites is dependent upon manufacturer. When using the opaque resin, the optical properties of each material must be considered as well as cavity.

The Ability of Auditory Stimuli to Mask Siren Sounds in a Vehicle Graphic Simulator (자동차 그래픽 시뮬레이터에서 사이렌 소리 자극에 따른 청각 자극의 마스킹 효과)

  • Park, Jung-Sun;Kim, Gyu-Beom;Jo, Hyeong-Seok;Kim, Gyeong-Rae;Kim, Jun-Hyeong;Min, Byeong-Chan
    • Science of Emotion and Sensibility
    • /
    • v.22 no.3
    • /
    • pp.47-54
    • /
    • 2019
  • We examined previous studies of the correlation analysis of heart rate variability as a method to reduce the stress caused by outside noise during driving, and we investigated whether there are electrocardiographic changes when drivers play music, which provides a stable sound source amid the noise. Because the number of cars increases every year, drivers and passengers show an increase in stress caused by outside noise. The stress from outside noise while a person is driving can cause several disorders, such as anxiety, immunosuppression, depression, and heart disease. Subjects in this study operated a vehicle simulator to reduce the stress from outside noise and were given different auditory stimuli, and we studied the drivers' responses to the stimuli. Repeated-measures analysis of variance revealed a significant differences between subjects exposed to different auditory stimuli (ρ < 0.05). Through post hoc analyses, we examined these differences. We found significant differences between factor 1 (stability) and factor 2 (simulation driving), between factor 1 (stability) and factor 3 (driving + police siren), and between factor 1 (stability) and factor 4 (driving + police siren + music). In addition, the factor that produced the highest level of sympathetic nervous system activity was factor 4 (driving + police siren + music), followed by factor 3 (driving + police siren), factor 2 (driving), and factor 1 (stability). In conclusion, even when a police siren was heard during driving, there were no significant differences on electrocardiograms (ECGs). In addition, even when the siren was heard over the music, there was no difference on the ECGs (ρ < 0.01). In future studies, investigators should determine which types of music help stabilize the heart rate during driving.

SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF METAL SUBSTRATE ON THE COLOR OF CERAMIC (금속하부구조물이 도재의 색조에 미치는 영향에 대한 분광측색분석)

  • Lee Su-Ok;Woo Yi-Hyung;Choi Dae-Gyun;Kwon Keung-Rok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.148-159
    • /
    • 2003
  • Statement of problem Metal-ceramic restorations have been used extensively by dental clinicians for nearly 40 years. Strength an functional ability of metal-ceramic restorations are proved to be satisfying, However esthetics and biocompatibility of metal alloy which is used in metal-ceramic restoration is not ideal. Using pure gold as an alternative, have advantage of esthetics, biocompatibility over conventional metal alloy. But there had been little article which studied on the color effect of pure gold on fual porcelain color. Purpose The purpose of this study was to spectrophotometrically evaluate the difference between color of metal alloy(Au-Pt, Ni-Cr) and pure gold, during color masking procedure with opaque porcelain and to analyze the differences, Material and Methods Three types of metal - base metal(Ni-Cr), high gold alloy(Au-Pt), pure gold(GES) - specimen were fabricated 1cm in diameter. Four steps were established - after finishing, after pre-coditioning, after application of first opaque porcelain(0.08mm in thickness), after application of second opaque porcelain(0.15mm in thickness)- and tested color with spectrophotometer every each steps and analyzed with $CIEL^*a^*b^*$ color order system. One-Way ANOVA test was used to and out if there were significant differences between groups tested and Shaffe multiple comparison was used to identify where the differences were. Results 1. After finishing and pre-conditioning, pure gold(GES) group showed most high values in $L^*,a^*,b^*$. 2. After application of first opaque porcelain(0.08mm in thickness), after application of second opaque porcelain(0.15mm in thickness), pure gold(GES) group showed the least difference in $L^*,a^*,b^*$ values and the lowest ${\Delta}E$ value(${\Delta}E$=0.63). 3. After application of first opaque porcelain and after application of second opaque porcelain differences that were significant (P<0.05) between groups were found only in $a^*$ values. 4. Base metal alloy group showed the lowest $a^*$ value in test after application of first opaque porcelain and the highest value in test after application of first opaque porcelain Conclusion Pure gold group and high gold group showed higher $a^*$ values than base metal group when tested after 0.08mm thickness of opaque porcelain was applied and pure gold group showed much similar $L^*,a^*,b^*$ values between 0.08mm thickness and 0.15mm thickness of opaque porcelain. This meant that pure gold was more easily masked by opaque porcelain than the other two groups.

INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS (수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향)

  • Bok Won-Mi;Choi Keun-Bae;Park Charn-Woon;Ahn Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.