• Title/Summary/Keyword: Mask evaluation

Search Result 140, Processing Time 0.037 seconds

Accident research II for the college students happened during Dental Laboratory Technology-major classes (치기공과 실습 중 안전사고 실태조사 II)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.131-153
    • /
    • 2005
  • The purpose of this study was to identify the accidents happened in the college dental laboratory technique classes and to realize the level of safety education for the dental laboratory technique major students. The research data were collected from a self-administered survey distributed to the conveniently selected college students whose majors were dental laboratory technology in Suwon, Daejeon, Daegu, Kimcheon, and Icsan. The study participants were 422 freshmen, sophomore and junior students in the selected cities. All collected survey responses were encoded and analyzed in SPSS 12.0. The findings were as follows. 1. The students who had any accidents in their laboratory classes were 36% and the other 64% answered 'no.' 2. Most injuries which the participants had were not significant. 3. The medical treatment periods of most injury cases were less than one week; however, approximately 20% of the self-reported injury cases reported that their treatment periods were longer than one week. 4. The body parts frequently injured from accidents were hands with 84.7% and arms, eyes, face, head, and legs in order. 5. Concerning the materials involved in the laboratory classes, most accidents happened when working with wax in 59.9%, with plaster in 52.3%, with wire in 39.8%, with alcohol in 34.6%, and casting iron in 22.2% in order. 6. The accident-prone laboratory methods were polishing with 53.5%, pickling or sanding with 17.4%, and casting or burning with 5.8% in order. 7. Most students wore their laboratory gowns well; however, few students wore mask before dust-involved jobs. Furthermore, only 57.1% students answered their laboratory fans worked during the polishing job. 8. Approximately 54% participant students answered that they took laboratory safety education when necessary only from the class instructors. 9. The 76.1% students responded that they needed laboratory safety education at least 1-2 times every semester. 10. The survey participants answered that the primary factors for injury prevention in their laboratory were taking safety education, wearing safety equipments, and providing safety-focused facilities. Concludingly, comprehensive evaluation and monitoring for potential risk factors from both the human side and the environment side should be continually provided to minimize the college laboratory accidents.

  • PDF

Evaluation of Workplace Protection Factors for Some Half-Facepiece Respirators in Welding Workplace (일부 반면형 호흡기 보호구에 대한 용접작업장에서의 Workplace Protection Factors(WPF) 평가)

  • Byeon, Sang-Hoon;Na, Myung-Chai;Kim, Hyunwook;Lim, Ho-Sub
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.14-22
    • /
    • 1999
  • This study was conducted to evaluate workplace protection factors(WPF) for two half-facepiece respirators (HR-1, HR-2) in welding workplace and to provide data on the workplace performance of negative-pressure, half-facepiece respirators against airborne particulate contaminants. The outside iron oxide(Fe2O3) concentration of welding fume for the respirator HR-1 ranged from 0.177 to $12.508mg/m^3$ with a geometric mean of $1.118mg/m^3$ and the HR-2 respirator showed a iron oxide range of 0.500 to $3.494mg/m^3$ with a geometric mean of $1.082mg/m^3$. But the inside oxide concentration of welding fume for the respirator HR-1 ranged from 0.002 to $0.364mg/m^3$ with a geometric mean of $0.019mg/m^3$ and the HR-2 respirator showed a iron oxide range of 0.012 to $0.639mg/m^3$ with a geometric mean of $0.041mg/m^3$. The iron oxide inside concentrations were significantly less than $5mg/m^3$(TLV) for both of respirators. The WPF were ranged from 3 to 3744 with a geometric mean of 60 for HR-1 and range from 2 to 129 a geometric mean of 26 for HR-2. And, in this study, the 5th percentile of the workplace protection factors for half-facepiece aspirators (HR-1, HR-2) were 11.2 and 7.1, respectively. The correlation relationship between the Quantative Fit Factors(QNFT) and the WPF for half-mask negative pressure respirators were 0.099 and 0.460.

  • PDF

A Study on Reliability Evaluation Using Dynamic Fault Tree Algorithm (시스템 신뢰도 평가를 위한 동적 결함 트리(Dynamic Fault Tree) 알고리듬 연구)

  • 김진수;양성현;이기서
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10A
    • /
    • pp.1546-1554
    • /
    • 1999
  • In this paper, Dynamic Fault Tree algorithm(DFT algorithm) is presented. This algorithm provides a concise representation of dynamic fault tolerance system including fault recovery techniques with fault detection, mask and switching function. And this algorithm define FDEP, CSP, SEQ, PAG gate which captures the dynamic characteristics of system. It show that this algorithm solved the constraints to satisfy the dynamic characteristics of system which there are in Markov and also this is able to satisfy the dynamic characteristics of system which there are in Markov and also this is able to covered the disadvantage of Fault tree methods. To show the key advantage of this algorithm, a traditional method, that is, Markov and Fault Tree, applies to TMR and Dual-Duplex systems with the dynamic characteristic and a presented method applies to those. He results proved that the DFT algorithm for solving the problems of the system is more effective than the Markov and Fault tree analysis model..

  • PDF

Enhanced Detection Sensitivity of Surface Plasmon Resonance Biosensing Based on Colocalized Target Molecules and Evanescent Fields (생체분자와 필드의 동시국소화를 통한 플라스몬 센서의 감도향상 연구)

  • Lee, Won-Ju;Oh, Young-Jin;Kim, Dong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.198-203
    • /
    • 2011
  • We have conducted a theoretical study to improve the detection limit of a surface plasmon resonance (SPR) sensor by co-localizing plasmonic fields and target molecules of interest. The fields were localized by nanograting antennas, while target molecules that participate in a molecular interaction were assumed to be co-localized by angled evaporation of a dielectric mask layer on the nanograting antennas. We have performed the evaluation using an overlap integral between distributions of plasmon fields and molecules and confirmed the correlation of the overlap with the sensitivity of an SPR sensor. Based on the calculated sensor characteristics, it was found that the sensitivity, if the fields and molecules are co-localized, can be as much as ten times that of non-colocalized structure.

A Study on the Actual Profile of Emergency Medical Personnel's Pre-admission Infection Control - Based on Jeollabuk-do provincial area - (병원 전 응급의료종사자의 감염관리 실태 연구 - 전북지역 중심으로 -)

  • Shin, Sang-Yol;Jeong, Tae-Oh
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.2
    • /
    • pp.19-27
    • /
    • 2007
  • Purpose: By identifying the actual profile of emergency medical personnel's pre-admission infection control practices, this study intended to provide a basic reference material for the improvement and reorientation of pre-admission infection control measures, and thereby help establish an effective plan for pre-admission infection control activities. Methods: Total 119 EMT's working for Jeollabuk-do Provincial Fire Defense HQ were asked to join a structured questionnaire survey from June to August 2006. Results: 1. It was found that 56.1% respondents answered no guideline available on the prevention of infection. Out of our rescue brigade members who knew about relevant guideline available, 34.2% respondents answered that their department conducted quality control program for the guideline. 2. For protective outfit in emergency practice, it was found that most respondents put on gloves or nothing at all(38%), which was followed by sterile gloves(29.2%), disposable mask(26.9%), gown(4.3%) and protective goggle(1.6%). And it was noted that all respondents(100%) washed out any clothing contaminated with somatic secretion on their own. 3. For a question about any experience in emergency activities exposed to infectious diseases, it was found that most of all respondents(77.9%) answered 'No', which was followed by 'Don't Know'(18.6%) and Yes(3.9 %). 4. For a question about any experience in inquiring of patients about infectious diseases, it was found that most respondents(49.4%) answered 'Yes' and 'Sometimes'(9.1%). It was noted that 20.2% respondents had extra medical examination in medical institution in terms of whether they were exposed to infectious diseases, apart from regular medical examination. Conclusions: In order to protect 119 EMT's from infectious diseases, it will be necessary to acquire emergency medical staffs specializing in infection control and organize corresponding personnel training units to keep providing reorientation and evaluation. In addition, it will be also necessary to supply them with a full set personal protection apparatuses and other equipments required for disinfection and sterilization.

  • PDF

Critical Care Medicine (호흡기내과 의사를 위한 Respiratory Review of 2010)

  • Park, Jie-Hae;Chae, Jin-Nyeong;Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.2
    • /
    • pp.75-80
    • /
    • 2010
  • The year of 2009~2010 brought a number of concepts and new ideas were evaluated with promising results. However, some studies that challenged many beliefs. In acute respiratory distress syndrome (ARDS), recent clinical studies took into consideration of pathophysiologic changes of respiratory system compliance. Meta-analysis of positive end-expiratory pressure trials showed survival benefit of high positive end-expiratory pressure in ARDS. Until now, prone positioning did not show survival benefit in patients with ARDS. Extracorporeal membrane oxygenation (ECMO) based management improved survival in patients with severe ARDS. ECMO can be a management option in severe ARDS. Sedation is a standard practice in critically ill patients needing mechanical ventilation. However, Danish group reported less sedation of critically ill patients receiving mechanical ventilation was associated with an increase in days without ventilation. Although this single center study has some limitations, the overall results are promising. Use of maximal sterile barrier precautions (mask, sterile gown, sterile gloves, and large sterile drapes) with chlorhexidine-impregnated dressing reduced central venous catheter related infection. Selective oropharyngeal decontamination (application of topical antibiotics in the oropharynx) reduced the mortality rate of an intensive care unit (ICU) population. Normoglycemia in Intensive Care Evaluation and Survival Using Glucose Algorithm Regulation (NICE-SUGAR) trial reported intensive glucose control increased mortality among adults in the ICU. Some of the results of above papers are promising. However, some ideas may need for more frequent individual assessment and increase the workload of ICU staffs. Before implementation of new practice in ICU, we should take into consideration of individual hospital situation including human and material resources.

Modified Gaussian Filter Considering Noise Characteristics in AWGN Environments (AWGN 환경에서 잡음 특성을 고려한 변형된 가우시안 필터)

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.3
    • /
    • pp.125-131
    • /
    • 2019
  • Through the 4th Industrial Revolution, various digital equipments are being distributed, and accordingly, the importance of data processing is increasing. As data processing has a great effect on the reliability of equipment, its importance is increasing, and various studies are being conducted. In this paper, we propose an algorithm to remove AWGN in consideration of the noise in the image. The proposed algorithm is used in the filtering process by inferring the standard deviation of the image noise. The noise is removed by dividing the filter for the high frequency component and the filter for the low frequency component compared with the standard deviation of the filtering mask. The proposed algorithm is simulated with the existing methods for evaluation and compared and analyzed by difference image, PSNR and profile. The proposed algorithm minimizes the effect of noise and preserves the important characteristics of the image and shows the performance of efficient noise removal.

An Improved VTON (Virtual-Try-On) Algorithm using a Pair of Cloth and Human Image (이미지를 사용한 가상의상착용을 위한 개선된 알고리즘)

  • Minar, Matiur Rahman;Tuan, Thai Thanh;Ahn, Heejune
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.2
    • /
    • pp.11-18
    • /
    • 2020
  • Recently, a series of studies on virtual try-on (VTON) using images have been published. A comparison study analyzed representative methods, SCMM-based non-deep learning method, deep learning based VITON and CP-VITON, using costumes and user images according to the posture and body type of the person, the degree of occlusion of the clothes, and the characteristics of the clothes. In this paper, we tackle the problems observed in the best performing CP-VTON. The issues tackled are the problem of segmentation of the subject, pixel generation of un-intended area, missing warped cloth mask and the cost function used in the learning, and limited the algorithm to improve it. The results show some improvement in SSIM, and significantly in subjective evaluation.

SEM/EDS Evaluation of Gold Bonding Agent Applied on Non-precious Alloys and Cast CP-Ti (도재 소부용 비귀금속 합금과 티타늄에 적용한 Gold Bonding Agent의 전자현미경적 평가)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of dental hygiene science
    • /
    • v.9 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • The purposed of this study was to investigate the effect of Gold bonding agent as intermediate layer between metal substrate and ceramic coating. Gold bonding agent used to seal off any surface porosity, to mask the greyish color of the metal, and to provide an underlying bright golden hue to the ceramic coverage. The adhesion between metal substrate and ceramic is related to diffusion of oxygen during ceramic firing. The oxide layer produced on non-precious alloy anti titanium was considered to have a potentially adverse effect on metal-ceramic bonding. The oxidation characteristics of titanium and non-precious alloys are the main problem. Every group were divided into test and control groups. Control groups are carried out process of degassing for product oxide layer. Au coating was applied on each Ni-Cr, Co-Cr alloys and cp-Ti specimens with difference surface condition or degassing. Specimens surfaces and cutting plane was characterized by SEM/EDS. Results suggested that Au coating is effective barriers to protect metal oxidation during ceramic firing.

  • PDF

General anesthesia with a transcutaneous pacemaker for a Noonan syndrome patient with advanced atrioventricular block discovered in the remote period after open-heart surgery: a case report

  • Emi Ishikawa;Makiko Shibuya;Ayako Yokoyama;Takayuki Hojo;Yukifumi Kimura;Toshiaki Fujisawa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.2
    • /
    • pp.111-116
    • /
    • 2023
  • We provided general anesthesia management to a patient with advanced atrioventricular block, which was discovered in the remote period after open-heart surgery. A 21-year-old man with Noonan syndrome was scheduled to undergo excision of a median intramandibular tumor. At 2 months of age, the patient underwent endocardial repair for congenital heart disease. During our preoperative examination, an atrioventricular block was detected, which had not been previously noted. Emergency drugs were administered, and a transcutaneous pacemaker was placed. During anesthesia induction, mask ventilation was easy, and intubation was performed smoothly using a video laryngoscope. The transcutaneous pacemaker was activated in demand mode at a pacing rate of 50 cycles/min approximately throughout the anesthesia time, and the hemodynamic status remained stable. The effect of intraoperatively administered atropine was brief, lasting only a few seconds. Although body movements due to thoracoabdominal muscle spasm were observed during pacemaker activation, they did not interfere with surgery. In postoperative patients with congenital heart disease, an atrioventricular block may be identified in the remote period, and preoperative evaluation should be based on this possibility. In addition, during anesthesia management, it is important to prepare multiple measures to maintain hemodynamic status.