• Title/Summary/Keyword: Marker-less

Search Result 235, Processing Time 0.031 seconds

Diagnostic Usefulness of Fine Needle Aspiration Cytology on Lymphadenopathy (림프절종대의 세침흡인 세포검사의 진단적 유용성 - 림프절의 세침흡인 세포검사 1,216예의 분석 -)

  • Kim, Dong-Won;Jin, So-Young;Lee, Dong-Hwa;Lee, Chan-Soo
    • The Korean Journal of Cytopathology
    • /
    • v.8 no.1
    • /
    • pp.11-19
    • /
    • 1997
  • Clinical lymphadenopathies are subjected to fine needle aspiration cytology(FNAC) for diagnosing not only benign lesions but also malignant ones, as the first diagnostic procedure. While the diagnostic reliability in metastatic carcinoma is high, it is difficult to differentiate malignant lymphoma from reactive conditions. We evaluated the diagnostic reliability of FNAC in lymphadenopathy, and discuss the diagnostic limitation and its place in clinical practice in this study, Over 8 years from January 1988, FNAC of 1,216 lymphadenopathies were analyzed and among them 170 cases were compared with histopathology. The results are as follows. 1. Of ail the cases, 890 cases(73.2%) were diagnosed cytologically as benign, 312 cases(25.7%) as malignant, and 14 cases(1.1%) as unsatisfactory material. Reactive hyperplasia was diagnosed in 585 cases(65.7%) of the benign lesions, and among the malignant diseases, metastatic carcinoma was diagnosed in 248 cases(79.5%), and malignant lymphoma in 62 cases(19.9%). 2. The overall diagnostic accuracy was 89.2%, and no false positive case and 9 false negative results were observed among 170 cases which were proven by histopathology. Six cases of sampling error of false negative diagnoses included 3 of metastatic carcinomas and 3 of malignant lymphomas. The causes were difference between aspiration and biopsy site, poor fixation, or scanty cellularity with bloody smear. All 3 cases of misinterpretation error were malignant lympliomas, one of mixed type on biopsy which was diagnosed as reactive hyperplasia cytologically. In summary, FNAC technique is thought to be useful in the initial diagnosis of lymphadenopathies as well as in the follow-up of patients with known malignancy. Although the results of malignant lymphoma was less accurate than other malignant lesions, the application of strict cytologic criteria or lymphoid marker studies of aspiration material will reduce the false negative rate.

  • PDF

Utility of Selected Non-coding Chloroplast DNA Sequences for Lineage Assessment of Musa Interspecific Hybrids

  • Swangpol, Sasivimon;Volkaert, Hugo;Sotto, Rachel C.;Seelanan, Tosak
    • BMB Reports
    • /
    • v.40 no.4
    • /
    • pp.577-587
    • /
    • 2007
  • Single-copy chloroplast loci are used widely to infer phylogenetic relationship at different taxonomic levels among various groups of plants. To test the utility of chloroplast loci and to provide additional data applicable to hybrid evolution in Musa, we sequenced two introns, rpl16 and ndhA, and two intergenic spacers, psaA-ycf3 and petA-psbJ-psbL-psbF and combined these data. Using these four regions, Musa acuminata Cola(A)- and M. balbisiana Colla (B)-containing genomes were clearly distinguished. Some triploid interspecific hybrids contain A-type chloroplasts (the AAB/ABB) while others contain B-type chloroplasts (the BBA/BBB). The chloroplasts of all cultivars in 'Namwa' (BBA) group came from the same wild maternal origin, but the specific parents are still unrevealed. Though, average sequence divergences in each region were little (less than 2%), we propose that petA-psbJ intergenic spacer could be developed for diversity assessment within each genome. This segment contains three single nucleotide polymorphisms (SNPs) and two indels which could distinguish diversity within A genome whereas this same region also contains one SNP and an indel which could categorize B genome. However, an inverted repeat region which could form hairpin structure was detected in this spacer and thus was omitted from the analyses due to their incongruence to other regions. Until thoroughly identified in other members of Musaceae and Zingiberales clade, utility of this inverted repeat as phylogenetic marker in these taxa are cautioned.

Approaches to Improving Production Efficiencies of Transgenic Animals

  • Tojo, Hideaki
    • Proceedings of the KSAR Conference
    • /
    • 2000.10a
    • /
    • pp.7-8
    • /
    • 2000
  • Transgenic animals are very useful for scientific, pharmaceutical, and agricultural purposes. In livestock, transgenic technology has been used forthe genetic alteration of farm animals, the production of human proteins inlarge quantities in the milk of transgenic farm animals, and the generation of animals with organs suitable for xenotransplantation. To date, the transfer of foreign genes into farm animals has been performed mainly by microinjection of DNA into the pronuclei of fertilized eggs. However, the overall success rate of transgenic animals in livestock so far has been disappointingly low, eg., the efficiency is 0∼5% in swine, and less than 1% in sheep and cattle, compared with the rate in mice where 5% microinjected develop into transgenic animals. Recently, McGreath et al. (2000) have succeeded in producing the gene targeted sheep by the use of nuclear transfer from cultured somatic cells transfected with a foreign gene in vitro. However, we may need plenty of time until currently employ this method for gene transfer to farm animals. We have been studying to exploit the method for improving production efficiencies of transgenic animals with emphasis of its application to farm animals. The present paper describes three approaches that we have made in our laboratory to improve production efficiencies of transgenic animals, based on the DNA microinjection method. 1. Co-injection of restriction enzyme with foreign DNA into the pronucleus for elevating production efficiencies of transgenic animals. 2. Efficient selection of transgenic mouse embryos using EGFP as a marker gene. 3. Phenotypes of tansgenic mice expressing WAP/hGH-CAG/EGFP fusion gene produced by selecting transgenic embryos. 4. Efficient site-specific integration of the transgene targeting an endogenous lox like site in early mouse embryos.

  • PDF

Studies on the Histones of the Genus Rhizopus (Rhizopus속의 histones에 관한 연구)

  • 민병례;이은영
    • Korean Journal of Microbiology
    • /
    • v.28 no.2
    • /
    • pp.128-133
    • /
    • 1990
  • The chromatin of all higher eukaryotic cells contains a group of very basic low-mole-cular weight proteins, the histones. But much less is known about histones in lower eukaryotes. Our purpose was to study the histones of the genus Rhizopus. After isolation and purification of nucleoprotein the basic nucleoproteins were analyzed by gel electrophoresis, in sodium dodecyl sulfate as well as acid/urea gels and compared with calf thymus histones. Their electrophoretic mobility in polyacrylamide gel indicate that they are histone homologous, although not identical, to the H2A, H2B, H3 and H4 histones of mammals with the exception of H1. The result suggests that Rhizopus thus appears to contain histone proteins which are homologous to the histones from in higher eukaryotes. The similarity between the calf thymus histone H1 and the Rhizopus high band group remains to be discussed.

  • PDF

Simultaneous Determination of 11 Marker Compounds in Gumiganghwal-tang by HPLC-DAD and LC-MS

  • Weon, Jin Bae;Jung, Youn Sik;Ryu, Gahee;Yang, Woo Seung;Ma, Choong Je
    • Natural Product Sciences
    • /
    • v.22 no.4
    • /
    • pp.238-245
    • /
    • 2016
  • Gumiganghwal-tang has been used for the treatment of common cold for a long-time. We developed an accurate and sensitive high performance liquid chromatography-diode array detection (HPLC-DAD) and electrospray ionization mass spectrometry method for the simultaneous determination of ferulic acid, baicalin, bergapten, methyl eugenol, glycyrrhizin, oxypeucedanin, wogonin, nodakenin, atractylenolide III, imperatorin, and atractylenolide I in Gumiganghwal-tang samples. The analytes were separated on a Shiseido C18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}250mm$) with gradient elution with acetonitrile and 0.1% trifluoroacetic acid. Eleven compounds were quantitatively determined by HPLC-DAD and identified by LC-MS data. We also validated this method. The calibration curves of all the compounds showed good linear regression. The limits of detection and the limits of quantification ranged from 0.04 to 0.63 and from 0.12 to $1.92{\mu}g/mL$, respectively. The relative standard deviation values of intra- and inter-days of this method represented less than 2.9%. The recoveries were found to be in the range of 90.06 - 107.66%. The developed method has been successfully applied to the analysis of Gumiganghwaltang samples. The established HPLC method could be used to quality control of Gumiganghwal-tang.

Image Fusion of Lymphoscintigraphy and Real images for Sentinel Lymph Node Biopsy in Breast Cancer Patients (유방암 환자의 감시림프절 생검을 위한 림포신티그라피와 실사영상의 합성)

  • Jeong, Chang-Bu;Kim, Kwang-Gi;Kim, Tae-Sung;Kim, Seok-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.114-122
    • /
    • 2010
  • This paper presents a method that registers a lymphoscintigraphy to the real image captured by a CMOS camera, which helps surgeons to easily and precisely detect sentinel lymph nodes for sentinel lymph node biopsy in breast cancer patients. The proposed method consists of two steps: pre-matching and image registration. In the first step, we localize fiducial markers in a lymphoscintigraphy and a real image of a four quadrant bar phantom by using image processing techniques, and then determines perspective transformation parameters by matching with the corresponding marker points. In the second step, we register a lymphoscintigraphy to a real images of patients by using the perspective transformation of pre-matching. To examine the accuracy of the proposed method, we conducted an experiment with a chest mock-up with radioactive markers. As a result, the euclidean distance between corresponding markers was less than 3mm. In conclusion, the present method can be used to accurately align lymphoscintigraphy and real images of patients without attached markers to patients, and then provide useful anatomical information on sentinel lymph node biopsy.

Adaptive Keyframe-Based Tracking for Augmented Books (증강 책을 위한 적응형 키프레임 기반 트래킹)

  • Yoo, Jae-Sang;Cho, Kyu-Sung;Yang, Hyun-S.
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.4
    • /
    • pp.502-506
    • /
    • 2010
  • An augmented book is an application that augments such multimedia elements as virtual 3D objects generated by computer graphics, movie clips, or sound clips to a real book using AR technologies. It is intended to bring additional education and entertainment effects to users. For augmented books, this paper proposes an adaptive keyframe-based page tracking method to estimate the camera's 6 DOF pose in real-time after recognizing a page and performing wide-baseline keypoint matching. For a page tracking, proposed method in this paper chooses a proper keyframe and performs a tracking in two step of coarse-to-fine stage. As a result, the proposed method in this paper guarantees a robust tracking to view-point and illumination variations and real-time.

Simultaneous Determination of Liquiritin, Nodakenin, Hesperidin and Glycyrrhizin in Bojungikgi-tang Using HPLC-PDA (HPLC-PDA를 이용한 보중익기탕 중 Liquiritin, Nodakenin, Hesperidin 및 Glycyrrhizin의 동시분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.57 no.3
    • /
    • pp.187-193
    • /
    • 2013
  • Bojungikgi-tang has been widely used for enhancement of physical fitness in Korea. The convenient, simple, and accurate high-performance liquid chromatography (HPLC) method was established for simultaneous determination of four marker compounds, liquiritin, nodakenin, hesperidin, and glycyrrhizin in Bojungikgi-tang (Buzhongyiqi-tang in Chinese, Hochuekkito in Japanese), a traditional Korean herbal prescription. The column for optimizing HPLC separation was used a Gemini $C_{18}$ column at column oven temperature of $40^{\circ}C$ with 1.0% (v/v) aqueous acetic acid (A) and 1.0% (v/v) acetic acid in acetonitirle (B) by gradient flow. The flow rate was 1.0 ml/min and the detector was a photodiode array (PDA) set at 254 nm, 280 nm, and 335 nm. Calibration curves of four components were acquired with $r^2$ values ${\geq}0.9999$. The recoveries were found to range 92.11~105.68% with relative standard deviations (RSDs, %) value less than 2.50%. The RSD values of intraand inter-day precision were 0.07~2.50% and 0.16~1.99%, respectively. The contents of liquiritin, nodakenin, hesperidin and glycyrrhizin in Bojungikgi-tang were 3.85~3.92 mg/g, 2.27~2.32 mg/g, 4.14~4.19 mg/g, and 3.39~3.45 mg/g, respectively. The established simultaneous analysis method will be effective for quality control of Bojungikgi-tang.

Quality Evaluation of Modified Bo-Yang-Hwan-O-Tang by Capillary Electrophoresis and High-performance Liquid Chromatography

  • Chen, Jianbo;Wu, Enqi;Zhu, Hongmei;Lee, Kwan-Jun;Chu, Van Men;Cho, Cheong-Weon;Kim, Young-Ho;Park, Yong-Ki;Lee, Won-Jae;Kang, Jong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2666-2670
    • /
    • 2011
  • High-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) were used to identify five active components in the modified herbal decoction Bo-Yang-Hwan-O-Tang (mBHT), i.e., amygdalin, decursin, paeoniflorin, salvianolic acid B, and calycosin-7-O-${\beta}$-D-glycoside. These components were identified by comparing their retention times and mass spectra with those of reference compounds. The conditions of both analytical methods were optimized and validated. Sufficient separation of target analytes was achieved using a buffer consisting of 40 mM sodium borate and 60 mM sodium dodecylsulfate (SDS) containing 10% methanol (pH 9.5) at 250 nm for CE analysis and gradient elution with a water-methanol mobile phase and ultraviolet (UV) photodiode array detector (DAD) at 250 nm for HPLC analysis. The mBHT components were determined within 65 min by HPLC and 16 min by CE. All calibration curves showed high linearity (R > 0.999) within the ranges tested. Intra-day and inter-day precision were less than 1.6% and 1.8% for HPLC and 2.5% and 4.8% for CE, respectively. The accuracy of the methods ranged from 98.8% to 102.3% for HPLC and from 95.9% to 108.2% for CE.

Incremental Expression of 14-3-3 Protein Beta/Alpha in Urine Correlates with Advanced Stage and Poor Survival in Patients with Clear Cell Renal Cell Carcinoma

  • Kaneko, Shiho;Matsumoto, Kazumasa;Minamida, Satoru;Hirayama, Takahiro;Fujita, Tetsuo;Kodera, Yoshio;Iwamura, Masatsugu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1399-1404
    • /
    • 2016
  • We investigated the urinary levels of 14-3-3 protein beta/alpha to evaluate their diagnostic significance with regard to clear cell renal cell carcinoma (ccRCC) and angiomyolipoma (AML). Urine samples from 91 patients with ccRCC, 16 patients with AML and 24 healthy volunteers were assessed. We used an enzyme-linked immunosorbent assay (ELISA) to quantify 14-3-3 protein beta/alpha levels in urine. Values were higher in patients with ccRCC than in those with AML and in healthy volunteers. High levels were associated with pathologic stage, lymph node status, distant metastasis and poor survival. Urinary levels of 14-3-3 protein beta/alpha were significantly increased in patients with small-sized carcinoma, irrespective of being less than 4.0 cm and 2.0 cm, compared with levels in patients with AML. This study is the first to report that increased expression of 14-3-3 protein beta/alpha in urine is associated with advanced stage and poor survival in patients with ccRCC. In addition, urinary 14-3-3 protein beta/alpha may differentiate AML from RCC, even when small sized. These results suggest that examination of urinary 14-3-3 protein beta/alpha could serve as a diagnostic and prognostic marker in patients with ccRCC.