• Title/Summary/Keyword: Mark density

Search Result 61, Processing Time 0.024 seconds

Effect on the Pyramid Structure with Saw Mark Density of Silicon Wafer Surface (실리콘 웨이퍼 표면의 saw mark 밀도에 따른 피라미드 구조의 영향)

  • Lee, Min Ji;Park, Jeong Eun;Lee, Young Min;Kang, Sang Muk;Lim, Donggun
    • Current Photovoltaic Research
    • /
    • v.5 no.2
    • /
    • pp.59-62
    • /
    • 2017
  • Surface texturing is affected the uniformity and size of pyramid with saw mark defect density. To analysis the influence of the saw mark defect density, we textured various si wafer. When the texturing process proceeds without the saw mark removal, silicon wafer of low-saw mark defect density showed small pyramid size of $3.5{\mu}m$ with the lowest average value of the reflectance of 10.6%. When texturing carried out after removal of the saw mark using the TMAH solution, we obtained a reflectance of about 11% and the large pyramid size of $5{\mu}m$. As a result, saw mark wafers showed a better pyramid structure than saw mark-free wafer. This result showed that saw mark can take place more smooth etching by the KOH solution and saw mark-free wafer is determined to be a factor that have a higher reflectance and a large pyramid.

A Burst-mode Automatic Power Control Circuit Robust io Mark Density Variations (마크 밀도 변화에 강한 버스트 모드 자동 전력 제어 회로)

  • 기현철
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.67-74
    • /
    • 2004
  • As data rate was increased, the conventional burst-mode automatic power control circuit caused errors due to the effort of the mark density variation. To solve this problem we invented a new structured peak-comparator which could eliminate the effect of the mark density variation even in high date rate, and revised the conventional one using it. We proposed a burst-mode automatic power control circuit robust to mark density variations. We found that the peak-comparator in the proposed automatic power control circuit was very robust to mark density variations because it affected very little by the mark density variation in high date rate and in the wide variation range of the reference current and the difference current.

Measurement of the fast Neutron Flux Density in the Bulk Shielding Experimental Tank of the TRIGA Mark-II Reactor Using Solid State Track Detector

  • Ro, Seung-Gy;Jun, Jae-Shik;Cho, Sae-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.334-338
    • /
    • 1973
  • The horizontal distribution of the fast neutron flux density in the Bulk Shielding Experimental Tank of the TRIGA Mark-II reactor at the steady power of 250 KW has been measured using a solid state track detector which is natural mica placed in contact with $^{232}$ Th fissile foil. The neutron flux density was calculated on the assumption that the fast neutron spectrum is similar to that from the thermal-induced $^{235}$ U fission. The resulting flux density distribution along the horizontal line from the center of the thermalizing column door is presented in tabular and graphical forms.

  • PDF

Marked correlation function as modified gravity probe

  • Zheng, Yi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.55.4-55.4
    • /
    • 2017
  • For modified gravity models with screening mechanisms, the signal of modified gravity is larger at low density areas. We could add a density weighted mark to galaxy correlation function and increase the signal to noise of modified gravity detection. Based on mock galaxy catalogs from modified gravity simulations, we try different mark functions and parameters to find the best choices for discreminating modified gravity from GR. In this talk I will present our marked correlation funciton results and discuss its advantages and disadvantages.

  • PDF

A Study on the Fatigue Strength of Lap Weld of LNG Tank (LNG탱크 겹침용접부의 피로강도에 관한 연구)

  • Kim, Jong-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3 s.33
    • /
    • pp.29-35
    • /
    • 1999
  • At the design of Mark III membrane type LNG tank, an analytical and experimental approach on the fatigue strengths of membrane and its welds are very important in order to assist designers and surveyors. In this study, fatigue tests of lap weld of Mark III membrane type LNG tank were carried out and cumulative damage factor was calculated in order to estimate the fatigue life by probability density function and rule methods. It contained the following tests and reviews : 1) The fatigue tests of lap weld of stainless steel according to statistical testing method recommended by JSME, 2)Preparation of S-N curve for lap welds considering the statistical properties of the results of fatigue tests. 3) Procedure for estimating the initiation life of fatigue crack of lap welds under variable loads by the rule lf classification society and probability density function, 4) Guideline for inspection of lap welds fo membrane type LNG tank.

  • PDF

Analysis of error correction capability and recording density of an optical disc system with LDPC code (LDPC 코드를 적용한 광 디스크 시스템의 에러 정정 성능 및 기록 용량 분석)

  • 김기현;김현정;이윤우
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.537-540
    • /
    • 2003
  • In this paper, we evaluated error correction performance and recording density of an optical disc system. The performance of Low-Density Parity Check code (LDPC) is compared to the HD-DVD (BD) ECC. The recording density of optical disc can be increased by reducing the redundancy of the user data. Moreover, since the correction capability of LDPC with decreased redundancy is better than that of BD, the recording density can also be increased by reducing the mark length of the data on the disc surface.

  • PDF

The Measurement of TRIGA Mark-III Core Power Distribution Using Fuel Temperature (핵연료온도측정에 의한 TRIGA Mark-III 원자로의 노심출력 분포유추)

  • Byung Jin Jun;Ji Bok Lee;Chang Kun Lee
    • Nuclear Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.160-178
    • /
    • 1983
  • A method which determines TRIGA Mark-III core power distribution by measuring fuel temperature is developed. The temperature measurement is performed by sweeping the already existing instrumented fuel elements which are loaded as an expedient of safe operation, and the number of fuel positions swept is 16. Experimental results are compared with those from computation using neutron diffusion theory. The maximum and standard deviations are 12 and 5%, respectively. It is confirmed that the estimation of rod power density of measuring fuel temperature is for more convenient than the conventional methods, and that it is proved to be very accurate as well.

  • PDF

Density-based Outlier Detection in Multi-dimensional Datasets

  • Wang, Xite;Cao, Zhixin;Zhan, Rongjuan;Bai, Mei;Ma, Qian;Li, Guanyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.12
    • /
    • pp.3815-3835
    • /
    • 2022
  • Density-based outlier detection is one of the hot issues in data mining. A point is determined as outlier on basis of the density of points near them. The existing density-based detection algorithms have high time complexity, in order to reduce the time complexity, a new outlier detection algorithm DODMD (Density-based Outlier Detection in Multidimensional Datasets) is proposed. Firstly, on the basis of ZH-tree, the concept of micro-cluster is introduced. Each leaf node is regarded as a micro-cluster, and the micro-cluster is calculated to achieve the purpose of batch filtering. In order to obtain n sets of approximate outliers quickly, a greedy method is used to calculate the boundary of LOF and mark the minimum value as LOFmin. Secondly, the outliers can filtered out by LOFmin, the real outliers are calculated, and then the result set is updated to make the boundary closer. Finally, the accuracy and efficiency of DODMD algorithm are verified on real dataset and synthetic dataset respectively.

Measurement and Correction of PCB Alignment Error for Screen Printer Using Machine Vision (2) (머신비전을 이용한 PCB 스크린인쇄기의 정렬오차측정 및 위치보정 (2))

  • 신동원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.96-104
    • /
    • 2003
  • This paper presents the measurement and correction method of PCB alignment errors for PCB screen printer. Electronic equipment is getting smaller and yet must satisfy high performance standard. Therefore, there is a great demand for PCB with high density. However conventional PCB screen printer doesn't have enough accuracy to accommodate the demand for high-resolution circuit pattern and high-density mounting capacity of electronic chips. It is because the alignment errors of PCB occur when it is loaded to the screen printer. Therefore, this study focuses on the development of the system which is able to measure and correct alignment errors with high-accuracy. An automatic optical inspection part measures the PCB alignment errors using machine vision, and the high-accuracy 3-axis stage makes correction for these errors. This system used two CCD cameras to get images of two fiducial marks of PCB. The centers of fiducial marks are obtained by using moment, gradient method. The first method is calculating the centroid by using first moment of blob, and the latter method is calculating the center of the circle whose equation is obtained by curve-fitting the boundaries of fiducial mark. The operating system used to implement the whole set-up is carried in Window 98 (or NT) environment. Finally we implemented this system to PCB screen printer.

A Performance Enhancement of Osteoporosis Classification in CT images (CT 영상에서 골다공증 판별 방법의 성능 향상)

  • Jung, Sung-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1248-1259
    • /
    • 2016
  • Classification methods based on dual energy X-ray absorptiometry, ultrasonic waves, and quantitative computed tomography have been proposed. Also, a classification method based on machine learning with bone mineral density and structural indicators extracted from the CT images has been proposed. We propose a method which enhances the performance of existing classification method based on bone mineral density and structural indicators by extending structural indicators and using principal component analysis. Experimental result shows that the proposed method in this paper improves the correctness of osteoporosis classification 2.8% with extended structural indicators only and 4.8% with both extended structural indicators and principal component analysis. In addition, this paper proposes a method of automatic phantom analysis needed to convert the CT values to BMD values. While existing method requires manual operation to mark the bone region within the phantom, the proposed method detects the bone region automatically by detecting circles in the CT image. The proposed method and the existing method gave the same conversion formula for converting CT value to bone mineral density.