• Title/Summary/Keyword: Marine Water Quality

Search Result 601, Processing Time 0.029 seconds

Effects of a Commercial Extruded Pellet on Growth Performance and Water Quality in Growing Olive Flounder Paralichthys olivaceus (육성기 넙치 배합사료의 성장 및 수질 평가)

  • Kim, Kang-Woong;Kim, Kyoung-Duck;An, Cheul-Min;Son, Maeng-Hyun;Lee, Bong-Joo;Han, Hyon-Sob
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.24 no.4
    • /
    • pp.602-608
    • /
    • 2012
  • This study was conducted to evaluate the effect of commercial extruded pellet (EP) diet on the growth and water quality compared with a raw fish moist pellet (MP) diet for flounder on field feeding experiments. Three replicate groups of 130 fish per each tank (initial weight of 380 g) were fed one of the EP and Moist pellet (MP) for 7 months. In field feeding experiment, no significant difference was observed in final mean weight of fish fed the experimental EP (1,233 g) and MP (1,237 g), and any noticeable problem caused by feeding the experimental EP was not found during the whole period of feeding trial. Feed efficiency of fish fed the experimental EP was higher than that of MP, and there was no significant difference in survival between the fish fed experimental EP and MP. The concentrations of SS, COD, TN and TP of seawater in tanks of MP groups were 1-5 times higher than those of EP groups. Therefore, these results strongly suggest that diet EP could be developed to replace MP diet for the marketable size of production for flounder without adverse effects on growth performance and water quality.

Ozone-produced Oxidants Improve Water Quality Parameters and Microbial Colony Counts in the Semi-Recirculating Aquaculture System for Olive Flounder Paralichthys olivaceus (반순환여과양식시스템에서 오존 유래 잔류산화물이 넙치(Paralichthys olivaceus) 사육수의 수질과 미생물에 미치는 영향)

  • Jung, Sangmyung;Park, Woogeun;Park, Seongdeok;Park, Jeonghwan;Kim, Jae-Won;Kim, Pyong-kih
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.751-760
    • /
    • 2021
  • This study investigated the changes in water quality parameters and microbial colonies when ozone was applied to a semi-recirculating aquaculture system (semi-RAS) for the olive flounder Paralichthys olivaceus (500 g in average weight). Concentrations of ozone-produced oxidants (OPO) in rearing tanks were maintained at 0, 0.014, 0.025 mg/L as Cl2 for 26 days. Except total ammonia nitrogen, nitrite nitrogen, nitrate nitrogen, phosphate phosphorus, chemical oxygen demand, and total suspended solids decreased significantly with increasing OPO concentration in daily and weekly monitoring (P<0.05). Colony forming unit (CFU) counts of heterotrophic marine bacteria decreased in an OPO concentration-dependent manner. Overall reduction rates of microbial colonies in the treatments were 80% higher than those of the control (P<0.05). During the experiment, the OPO concentration-driven ozonation was reliably practiced without any adverse effects on the animals cultured in semi-RAS. Considering the biohazard, operating cost, and stability of ozonation, an OPO concentration of 0.014 mg/L would be sufficient to control water quality parameters and microbial colonies in a semi-RAS.

Study on the Cathodic Protectioin Behavior of Hot Water Boiler by Mg-Alloy Galvanic Anode (Mg 합금유전양긍에 의한 온수보일러의 음극방식거동에 관한 연구)

  • 정기철
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.115-121
    • /
    • 2000
  • As the development of industry water quality of river is going to bad because of waste water of an industrial complex and general home agricultural chemicals exhaust of $SO_3$ and CO gas acid rain and so on. Corrosion damage of boiler factory equipment and so forth occur quickly due to using of the polluted water resulting in increasing leak accident. Especially working life of hot water boiler using the polluted water becomes more short and energy loss increases. The cathodic protection method is the most economical and reliable one to prevent corrosion damage of steel structures. Mg-base alloys galvanic anode protection of cathodic protection method is suitable for than application of hot water boiler using water with high specific resistance such as tap water. This paper is studied on the cathodic protection characteristics of how water boiler. In tap water and 0.001mol/$\ell$ NaCl solution the characteristics of anodic polarization of Mg-base alloys galvanic anode and tube material is investigated the measurement of cathodic protection potential according to the time elaspsed is carried out.

  • PDF

Effects of feeding rate and number of meal on growth and body composition of ayu Plecoglossus altivelis

  • Cho, Sung-Hwoan;Lee, Jong-Kwan;Lee, Jong-Ha;Lim, Young-Soo;Park, Jung-Youn;Lim, Han-Kyu;Lee, Sang-Min
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.05a
    • /
    • pp.319-321
    • /
    • 2001
  • Supply of ntrition-balanced feed is very important for growth of fish, especially for growth of early period of fish. Therefore, most of commercial feeds for larval and juvenile fish are relatively expensive due to high level of the several nutrients to satisfy their requirements for growth. Overfeeding larval fish may increase fish production cost because of larvae feeds high price and deteriorate water quality, eventually reduce growth of fish. (omitted)

  • PDF

Pre-cooking and liquid smoke affect the physicochemical and microbiological quality and polyhydroxy aromatic hydrocarbon (PAH) content in smoked skipjack tuna (Katsuwonus pelamis L.)

  • Silvana Dinaintang Harikedua;Ella Dertina Saragih;Eunike Louisje Mongi;Lena Jeane Damongilala;Netty Salindeho;Henny Adeleida Dien;Nurmeilita Taher;Helen Jenny Lohoo;Mayse Sofien Siby
    • Food Science and Preservation
    • /
    • v.31 no.2
    • /
    • pp.210-217
    • /
    • 2024
  • This study aimed to compare the quality of smoked fish products processed with liquid smoke with and without pre-cooking when stored at room temperature (25℃) for 0, 2, 4, and 6 days. The observations included moisture content, water holding capacity, color, and total plate and mold counts. The treated samples were also analyzed for polyhydroxyaromatic hydrocarbons (PAHs) at day 0. The study found that the pre-cooked products had a lower moisture content (55.1%) than the control (59.9%) during storage. Additionally, the pre-cooked product had a higher water holding capacity than the control. The TPC value indicates that the pre-cooked product meets the Indonesian standard for smoked fish up to the 2nd day of storage, whereas the control product only meets the standard on day 0. However, the total mold of the control products meets the Indonesian standard until the 2nd day of storage, while the pre-cooked products only meet the standard on day 0. The pre-cooked product had a higher lightness value (L*) than the control. The analysis of polyhydroxy aromatic hydrocarbon (PAH) showed that the pre-cooking process did not affect the concentration of PAH.

Summer Water Quality Management by Ecological Modelling in Ulsan Bay (생태계 모델을 이용한 울산만의 하계 수질관리)

  • Park, Sung-Eun;Hong, Sok-Jin;Lee, Won-Chan;Jung, Rae-Hong;Cho, Yoon-Sik;Kim, Hyung-Chul;Kim, Dong-Myung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Numerical study on coastal water quality management was conducted to examine the response of summer water quality to the flow into the sea of land based pollution load in Ulsan Bay, Korea The abatement of pollution load. from point sources of land was estimated on the basis of Korean coastal water quality standard using an ecosystem model. The results of the ecological model simulation showed that COD values in the inner part of the bay were greater than 280mg/L, and exceeded the grade III limit of Korean coastal water quality standard 30% of all land based pollution loads or organic and inorganic material loads from point sources should be cut down to keep the COD levels below 2mg/L. As environmental carrying capacity was estimated to be 7,193kgCOD/day to keep the COD levels below 2mg/L in Ulsan Bay, 3,083kgCOD/day of land based organic loads should be reduced. The phytoplankton blooms have occurred in the Teahwa river mouth or estuary repetitively, so it is important to control land based nutrients loads for removal of autochthonous organic loads around Ulsan Bay.

Effective Costal Environmental Management by Conjugation of Modeling of Bio-Purification and Total Allowable Pollutant Loads in Masan Bay (생물정화기작과 총허용오염부하량을 연계한 마산만의 효율적 해양환경 개선방안)

  • Eom, Ki-Hyuk;Kim, Gui-Young;Lee, Won-Chan;Lee, Dae-In
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.38-46
    • /
    • 2012
  • This study carried out current status, characteristics, and problems of coastal environment management on semi-enclosed Masan Bay in Korea and suggests cost-effective and eco-friendly water quality management policy. The pollutants from terrestrial sources into the Bay have apparently environmental pollution problems, such as eutrophication, red tide, and hypoxia. The carrying capacity of the Bay is estimated by hydrodynamic model and ecosystem model, material circulation including bivalve in ecosystem is analyzed by the growth model of bivalve. The resulting reduction in the input load was found to be 50~90%, which is unrealistic. When the efficiency of water quality improvement through bivalve farming was assessed based on the autochthonous COD, 30.7% of the total COD was allochthonous COD and 69.3% was autochthonous COD. The overall autochthonous COD reduction rate by bivalve aquaculture farm was found to be about 6.7%. This study indicate that bivalve farming is about 31% less expensive than advanced treatment facilities that remove both nitrogen and phosphorous.

Geochemical Indicators for the Recovery of Sediment Quality after the Abandonment of Oyster Crassostrea gigas Farming in South Korea (굴(Crassostrea gigas)양식 중단 이후 퇴적물 질 회복에 관한 지화학적 지표 탐색)

  • Sim, Bo-Ram;Kim, Hyung Chul;Kang, Sungchan;Lee, Dae-In;Hong, SokJin;Lee, Sang Heon;Kim, Yejin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.5
    • /
    • pp.773-783
    • /
    • 2020
  • In order to evaluate the recovery of fishing ground environment after the cessation of aquaculture farming, we examined the variation in sediment quality over time using different geochemical factors and investigated whether these factors are indicators of sediment quality recovery. The study area was an oyster Crassostrea gigas, farm in Tongyeong, Geyongsangnam-do, South Korea, where aquaculture activities had been carried out for 20 years, and the changes in water and sediment environment were monitored for 14 months after the abandonment of the farm. The mean water depth was 14 m, with a tidal range of 3 m, and seawater current velocity ranged from 4.7 to 7.0 cm/s. After the abandonment of the farm, total organic carbon and total nitrogen concentrations in the surface sediments decreased significantly over time compared to those in the control site; in particular, immediately after farm abandonment, acid-volatile sulfide concentrations decreased relatively rapidly. Carbohydrate and protein concentrations in the sediments showed no significant changes; however, lipid concentrations markedly decreased. Further studies on other aquaculture taxa and various aquaculture areas are needed to establish new policies for environmental management of fishing grounds, such as relocation of fishing grounds and determination of optimal fallowing periods.

Temporal and Spatial Fluctuations of Coastal Water Quality and Effect of Small Tide Embankment in the Muan Peninsula of Korea (무안반도 연안수질의 시ㆍ공간적 변동과 소규모 방조제의 영향)

  • Lee Dae-In;Cho Hyeon-Seo;Lee Gyu-Hyung;Lee Moon-Ok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.4
    • /
    • pp.24-36
    • /
    • 2003
  • In this study, we estimated the seasonal fluctuations of water quality and effect of small tide embankment in coastal water around the Muan Peninsula, which is located in the northern part of Mokpo city, and layer farming ground is spread around there. Some physical and chemical factors were analyzed to characterize water quality from Jan. to Oct. in 1994. The results were as follows: Dissolved oxygen was slightly under saturation in the almost areas of July, and in some bottom layer at ebb tide of October. Distribution of COD showed high values that over 2㎎/L in October and flood tide of April by the discharge of freshwater and resuspension of benthic sediment, which exceeded water quality criteria II. Maximum values of dissolved inorganic nitrogen ware appeared in surface layer during the flood tide of October, while minimum of that showed in surface layer in April. Concentration of dissolved inorganic phosphorus was higher at July than the others, which ranged from 0.24 to 2.08㎍-at/L. Mostly mean values of N/P ratio were lower than 16, it mean that nitrogen is more limiting nutrient than phosphorus for the growth of phytoplankton. The values of eutrophication index were in the range of 0.07~0.81. However, very high values due to increase of COD were estimated near the tide embankment and southern part in relation to tidal current in October. Water quality around tide embankment was suddenly changed worse within a short period after opening the water gate during the rainfall.

  • PDF

Removal of Suspended Solids Using a Flexible Fiber Filter in a Recirculating Aquaculture System (유연성 섬유사 여과기를 이용한 순환여과식 양식장의 부유고형물 제거)

  • Choi, Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.40 no.2
    • /
    • pp.73-78
    • /
    • 2007
  • The suitability of a flexible fiber filter for removing suspended solid (SS) in a recirculating aquaculture system was evaluated. This study focused on variation in the performance with a change in filtering time, influent water quality, and filtering mode duration. The particle distribution diagram of the filter effluent showed that the number of particles bigger than $5-8{\mu}m$ decreased dramatically, and the removal efficiency exceeded 80%. Although the removal efficiencies of SS and chemical oxygen demand (COD) were dependent on the quality of the influent, the SS and COD concentrations of the effluent were not affected by the influent concentrations. This was despite the deterioration if water quality after feeding in the rearing tank. The performance of the filter was not affected by the filtering mode duration, feeding conditions, or filtering time. The SS concentration and turbidity of the recirculating-type rearing tank were 30% and 50% lower, respectively, than of the a non-recirculating-type rearing tank under the same operating conditions. The flexible fiber filter was applicable to a recirculating aquaculture system that uses plenty of seawater, based on its low filtering resistance $(2kg_f/cm^2)$, high flux $(330m^3/m^2/hr)$, and high fine particle removal efficiency (80%, $5-8{\mu}m$).