• Title/Summary/Keyword: Marginal bone resorption

Search Result 77, Processing Time 0.02 seconds

The influence of magnet on tissue healing after immediate implantation in fresh extraction sites in dogs (성견에서 발치 후 즉시 식립 임플란트에 설치한 자석이 주위 조직에 미치는 영향)

  • Yu, Seok-Min;Cho, In-Ho;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.435-444
    • /
    • 2009
  • Statement of problem: The clinical use of electric and electomagnetic fields for fracture healing applications began in the early 1970s. Since then, several technologies have been developed and shown to promote healing of fractures. Developments of these devices have been aided in recent years by basic research and several well controlled clinical trials not only in the medical field but in dentistry. Purpose: The purpose of this study was to compare alveolar bone reduction following immediate implantation using implants onto which magnets were attached in fresh extracted sockets. Material and methods: Four mongrel dogs were involved. Full buccal and lingual mucoperiosteal flaps were elevated and third and fourth premolars of the mandible were removed. Implants with magnets and implants without magnets were installed in the fresh extracted sockets and after 3 months of healing the animals were sacrificed. The mandibles were dissected and each implant sites were sampled and processed for histological examination. Results: The marginal gaps that were present between the implant and walls of the sockets at the implantation stage disappeared in both groups as a result of bone fill and resorption of the bone crest. The buccal bone crests were located apical of its lingual counterparts. At the 12 week interval the mean of marginal bone resorption in the control group was significantly higher than that of the magnet group. The majority of specimens in magnet group presented early bone formation and less resorption of the buccal marginal bone compared to the control group. Conclusion: Within the limitations of this study, it could be concluded that implants with magnets attached in the early stages of implantation may provide more favorable conditions for early bone formation and reduce resorption and remodeling of marginal bone.

Influence of platform switching on crestal bone resorption (치조정 골흡수에 대한 platform switching이 미치는 영향)

  • Kim, Do-Young;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • Purpose: Numerous studies have shown that crestal bone resorption around the implant was related to the location of the implant abutment junction(IAJ). Recently it was hypothesized that platform switching termed the inward horizontal repositioning of the IAJ might limit bone resorption around the implants. The purpose of this clinical study was to evaluate the effect of platform switching on crestal bone resorption. Materials and Methods: The crestal bone loss of 65 external hex implants in 26 patients were radiographically measured at crown placement and follow-up examinations. 23 standard implants(non-platform switching group, NP) were connected with the matching abutments and 42 wide implants(platform switching group, PS) were connected with the 1 mm smaller diameter abutments. Results: There was significant difference of crestal bone loss between NP group and PS group. For implants in the NP group, mean crestal bone loss was $1.18{\pm}0.68\;mm$ at crown placement and $1.42{\pm}0.41\;mm$ at follow-up. The meal bone loss in PS group was $0.47{\pm}0.52\;mm$ at crown placement and $0.60{\pm}0.65\;mm$ at follow-up. When the crestal bone changes according to placement depths of implants were compared, subcrestal position of IAJ had a significantly less bone loss in PS group, but it was not in NP group. Conclusion: Within the limits of the present study, it was concluded that platform switching technique might decrease crestal bone loss around the implants. Additionally, when the IAJ of implant was placed 1 mm deeper in the alveolar bone, the effect of platform switching on bone loss was enhanced.

THE MANAGEMENT OF TRAUMATICALLY INTRUDED TEETH : A CASE REPORT (외상에 의해 함입된 치아의 치료증례)

  • Han, Young-Hee;Kim, Kwang-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.21 no.2
    • /
    • pp.518-524
    • /
    • 1994
  • A traumatically intruded tooth is one that is forcefully and abruptly dispaced from its position into the surrounding alveolar bone. Although intrusion of permanent teeth is infrequent, the sequelae compromise the longevity of the tooth and often include pulp necrosis, internal and external root resorption, rupture of periodontal ligament and loss of marginal bone. The purpose of this study was to examine three common management techniques for traumatic intrusion, observation for re-eruption, surgical repositioning & fixation and orthodontic extrusion. In the recent, the accepted treatment was to allow the permanent teeth to reerupt spontaneously for 6-8 weeks. If this did not occur, orthodontic traction was applied. The pulpal status of the teeth was monitored and either calcium hydroxide therapy or conventional endodontics was instituted following pulpal necrosis depending on the maturity of the root end. Pulpectomy and a calcium hydroxide filling were also the treatment of choice if there was evidence of internal or external root resorption. This will reduce the chance of root resorption and provide a period of monitoring prior to a definitive root canal filling.

  • PDF

Early Marginal Bone Loss around Submerged Implants According to the Patterns of Cover Screw Exposures (Submerged 임플란트에서 덮개나사 노출 양상에 따른 조기 변연골 상실)

  • Choi, Mee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.175-182
    • /
    • 2013
  • The purpose of this study was to observe and analyze the initial marginal bone resorption changes according to the patterns of cover screw exposures during healing period followed by implants installation. Total 64 fixtures(TiUniteTM, NobelBiocare, Sweden) were installed in partially edentulous jaws of 28 patients, who were selected retrospectively and were shown at least one cover screw exposure. Cover screw exposures were defined at 1 month recall. According to the patterns of exposures, groups were categorized into group 1 (No exposure), group 2 (pin-point exposure), group 3 (less than 1/2 of cover screw), group 4 (more than 1/2 of cover screw), group 5 (total exposure). Periapical radiographs were taken in purpose of changes of marginal bone level between installation and 2 month recall. Healing abutments were secured on the exposure groups at 2 month recall. Results were as follows: 1. Marginal bone resorptions were identified whenever cover screws were exposed. 2. Group 2 and 3 were shown significantly increased bone loss more than other group (P <.05). 3. Group 4 and 5 were shown significantly increased bone loss more than group 1, however, less than other groups ( P <.05). Conclusionally, cover screw exposure may cause marginal bone resorptions, therefore, early connection of healing abutment is clinically helpful.

Effects of implant collar design on marginal bone and soft tissue (임플란트의 collar design이 변연골과 연조직에 미치는 영향)

  • Yoo, Hyun-Sang;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the effects of implant collar design on marginal bone change and soft tissue response by an animal test. Materials and methods: Two types of Implant (Neobiotech Co. Seoul, Korea) that only differs in collar design were planted on two healthy Beagle dogs. The implants were divided into two groups, the first group with a beveled collar (Bevel Group) and the second group with "S" shaped collar (Bioseal group). Standardized intraoral radiographs were used to investigate the mesio-distal change of the marginal bone. Histological analysis was done to evaluate the bucco-lingual marginal bone resorption and the soft tissue response adjacent to the implant. Mann-Whitney test was done to compare the mesio-distal marginal bone change at equivalent time for taking the radiographs and the tissue measurements between the groups. Results: Radiographic and histological analysis showed that there was no difference in marginal bone change between the two groups (P>.05). Histological analysis showed Bioseal group had more rigid connective tissue attachment than the Bevel group. There was no difference in biological width (P>.05). Bevel group showed significantly longer junctional epithelium attachment and Bioseal group showed longer connective tissue attachment (P<.05). Conclusion: For three months there were no differences in marginal bone change between the Bevel group and the Bioseal group. As for the soft tissue adjacent to the implant, Bioseal group showed longer connective tissue attachment while showing shorter junctional epithelium attachment. There were no differences in biologic width.

Evaluation of the Availability of Implant placement using Ridge Expansion Osteotomy (REO) (치조능확장골절단술을 이용한 임프란트 식립술의 유용성 평가)

  • Kim, Yeong-Gyun;Yun, Pil-Yeong;Kim, Beom-Su
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.243-247
    • /
    • 2008
  • Purpose : Ridge expansion osteotomy (REO) has been introduced when it is necessary to expand narrow crestal ridge with simultaneous implant placement. This study has designed to evaluate the clinical availability of REO. Materials and methods : Subject were patients who had visited Seoul National University Bundang Hospital from July. 2003 to December, 2005 for implant placement using REO by one surgeon. Intraoperative and postoperative complication, failure of initial osseointegration and marginal bone resorption were estimated using electronic medical record and periapical radiography. Twenty?three patients, 8 males and 15 females, mean age 51, ranged 18 to 72, were treated for mean 26 months, ranged from 16 months to 46 months. Results : Mean diameter and length of implants placed at upper anterior, were 3.72mm and 13.32mm each other. Guided bone regeneration and ridge splitting were accompanied in this study. Five cases of cortical bone fracture, three cases of crestal bone loss more than 2mm, 2cases of gingival recession, and 2 cases of infection were noted, but there were no implants removed because of disintegration. Success rate of implant was 91.7%, even if survival rate of implant was 100%. In addition, there were no statistical significance between the success rate of REO and bone graft(p>0.05). Conclusion : Based on the results of the present study, it can be concluded that REO technique is reliable for implant placement at atrophic ridge with adequate height compared to bone graft and other osteotomies for ridge expansion, but care should be taken of esthetic problem such as gingival recession because of crestal bone resorption from trauma by osteotome.

  • PDF

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

EFFECTS OF EARLY FUNCTIONAL LOADING ON BONE FORMATION AROUND TITANIUM PLASMA SPRAYED IMZ IMPLANTS IN DOGS (성견에서 Titanium Plasma Sprayed IMZ 임플란트에 가해진 조기 기능하중의 골유착 및 골형성에 미치는 영향)

  • Jeon, Young-Sik;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.550-568
    • /
    • 1995
  • The purpose of this study was to observe the effects of early functional on bone formation around titanium plsama sprayed IMZ implants. 15 IMZ implants were inserted on the mandibular premolar areaa in 5 mondgrel dogs. The inplants were divided into 4 groups according to it’s loading schedule : Temporary abutments were connected for functional loading 6weeks, 9weeks, and 12weeks after implants installation in group I, II, and III, respectively. Abutments were not connected in the control group. After polyfluorochrome sequential labeling, all animals were sacrificed and bone sections includig implants and the 1st. molar were removed and processed for histologic evaluation. From light and fluorescence microscopic evaluation as well as histomorphometric and EPMA analysis, following results were obtained : 1. Light microscopically, the osteoid tissues were observed much in the compact bone of unloaded group, and cancellous bone formation observed more in early loaded group. 2. Calcification and remodeling of bone took place faster in loaded group, especially in 6 weeks group. 3. Moderate to severe marginal bone resorption was observed in 6 weeks group, mainly on buccal crest. 4. There was no difference in the percentages of bone-to-metal contact among the experimental groups. 5. In quantitative analysis using EPMA, there was no difference in the content of calcium and phosphorus among the experimental groups, regardless of distance.

  • PDF

Prognosis of Alveolar Bone Graft Alveolus in Cleft Patients : the preliminary report (치조열환자에서 치조골 이식술의 예후)

  • Lee, Su-Yeon;Myoung, Hoon;Seo, Byoung-Moo;Hwang, Soon-Jung;Lee, Jong-Ho;Kim, Myung-Jin;Choi, Jin-Young
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.9 no.2
    • /
    • pp.71-78
    • /
    • 2006
  • The case records of 24 patients in Seoul National University Hospital who had bone grafting of 29 alveolar clefts between 2001 and 2004 were examined. Details were recorded of age, sex, preoperative orthodontictreatment, the time of bone grafting, the type of donor site, cleft width, functional load applicationand the success of grafting as established by lowest marginal bone levels. Using this results and review of literature, we concluded that secondary bone graft with iliac bone before canine eruption with root development of 1/2 to 1/3 provide more favorable results and the functional load introduced to the grafted bone lower the resorption rates.

  • PDF

THE INFLUENCING FACTORS OF $PERIOTEST^(R)$ VALUE AND IMPLANT STABILITY QUOTIENT ($Periotest^(R)$ Value와 Implant Stability Quotient에 영향을 미치는 요소)

  • Yi Young-Ah;Cha In-Ho;Lee Ho-Yong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.40-50
    • /
    • 2006
  • Statement of problem: $Periotest^(R)\;and\;Osstell^{TM}$ were known as the most objective and quantitative mobility tests available for evaluating stability of implant in vivo. Although a correlation between PTV widely used and ISQ recently introduced exist, a PTV was corresponded to various ISQ. A correct evaluation of implant stability could be obtained only after one has a thorough understanding of the limitations of devices and factors that affect measurements. Purpose: The purpose of this study was to investigate the causes of variables in the values obtained with these two tests. Material and method: A total of 333 implants 134 $Br{\aa}nemark$, 5 Silhouette and 194 ITI implants were investigated. Result: 1. There was a correlation between PTV and ISQ (Spearman correlation =0.39, p<0.0001) 2. The factors that affected ISQ were diameter of implant future, location of implant and implant system (submerged type vs non-submerged type). 3. The factors that affected W were dimeter of implant future, location of implant, and elapsed time after implant placement. 4. There was no significant difference between different surface treatments of RBM, smooth surface and ti-unite on PTY and ISQ. 5. In radiographic finding, no saucerization or bone resorption has been detected in implants with ISQ values that were above the average level of each PTV. These higher values had higher bone densities around the implant fixture. Saucerization was observed in the most impants with ISQ values that were below the average level of each PTV. Conclusion: There was a correlation between ISQ and PTV. However, each measuring methods had factors influencing the measured values. PTV were less sensitive to marginal bone resorption and influenced with the striking point on an implant to the level of bone. With ISQ, the height of implant from bone level to transducer should be considered.