• Title/Summary/Keyword: Manufacturer's instruction

Search Result 31, Processing Time 0.024 seconds

Antibiotic Resistant Microbial Contamination (Enterobacter cloacae) Derived from Egg Yolk and Frozen Semen Extender in Porcine In Vitro Fertilized Embryos

  • Kwak, Seong-Song;Jeong, Se-Heon;Jang, Seung-Hoon;Jeon, Yu-Byeol;Nam, Young-Hee;Biswas, Dibyendu;Lee, Wan-Kyu;Hyun, Sang-Hwan
    • Journal of Embryo Transfer
    • /
    • v.25 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • The present study was to investigate the source of contamination during semen processing for in vitro uses. In the present study, frozen semen was prepared from liquid semen in our laboratory for in vitro fertilization (IVF) experiments due to lack of fresh semen. Antibiotics were added in the frozen semen extender (kanamycin and gentamicin) and in vitro culture (IVC) medium (gentamicin) for further inhibiting growth of microorganisms. Nevertheless, proliferations of microorganisms were observed in IVC culture drop during culturing of IVF embryos using frozen semen. Randomly 3 samples were taken from the liquid semen, frozen semen and egg yolk. Contaminated IVC medium, frozen-thawed semen, liquid semen and egg yolk were cultured in de Man, Rogosa and Sharpe (MRS) agar medium. Whitish colonies were detected in contaminated IVC drop, frozen-thawed semen samples and egg yolk but no colonies were formed in liquid semen samples. Gram-negative and rod-shaped identical bacteria were found in both frozen-thawed semen sample and contaminated IVC drop and egg yolk samples. Enterobacter cloacae were confirmed by API 20E kit according to manufacturer's instruction with identification value (% ID) 94.3% and T index 0.88. Antibiotic susceptibility tests were done according to Clinical and Laboratory Standards Institute (CLSI) by using ampicillin, amikacin, cephalothin, gentamicin, kanamycin, tetracycline, oxytetracycline, sulfamethoxazole trimethoprim, norfloxacin and ciprofloxacin test. Among them Enterobacter cloacae were resistant to ampicillin, amikacin, cephalothin, gentamicin, kanamycin but susceptible to tetracycline, oxytetracycline, sulfamethoxazole trimethoprim, norfloxacin and ciprofloxacin. From these findings it could be suggested that this contamination sources might be from egg yolk.

PHOTOCATALYTIC ANTIEUNGAL ACTIVITY AGAINST CANDIDA ALBICANS BY $TiO_2$ COATED ACRYLIC RESIN DENTURE BASE

  • Yang Ji-Yeon;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.284-294
    • /
    • 2006
  • Statement of problem. Proliferation of Candida albicans is primarily within the plaque on the fitting surface of the denture rather than on the inflamed mucosa. Consequently, the treatment of the denture is equally important as treatment of the tissue. Cleansing and disinfection should be efficiently carried-out as the organisms can penetrate into the voids of the acrylic resin and grow in them, from which they can continue to infect and reinfect bearing tissues. Purpose. The purpose of this study was to evaluate the applicability of photocatalytic reaction to eliminate Candida albicans from acrylic resin denture base, and to investigate the anti-fungal effect with various UVA illumination time. Materials and Methods. The specimens were cured by the conventional method following the manufacturer's instruction using thermal polymerized denture base resin (Vertex RS: Dentimex, Netherlands). $TiO_2$ photocatalyst sol(LT), which is able to be coated at normal temperature, was made from the Ti-alkoxide progenitor. The XRD patterns, TEM images and nitrogen absorption ability of the $TiO_2$ photocatalyst sol(LT) were compared with the commercial $TiO_2$ photocatalyst P-25. The experimental specimens were coated with the mixture of the $TiO_2$ photocatalyst sol(LT) and binder material (silane) using dip-coater, and uncoated resin plates were used as the control group. Crystallinity of $TiO_2$ of the specimen was tested by the XRD. Size, shape and chemical compositions were also analyzed using the FE-SEM/ EDS. The angle and methylene blue degradation efsciency were measured for evaluating the photocatalytic activity of the $TiO_2$ film. Finally, the antifungal activity of the specimen was tested. Candida albicans KCTC 7629(1 ml, initial concentration $10^5$ cells/ ml) were applied to the experiment and control group specimens and subsequently two UVA light source with 10W, 353 nm peak emission were illuminated to the specimens from 15cm above. The extracted $2{\mu}l$ of sample was plated on nutrient agar plate ($Bacto^{TM}$ Brain Heart Infusion; BD, USA) with 10 minute intervals for 120 minute, respectively. It was incubated for 24 hours at $37^{\circ}C$ and the colony forming units (CFUs) were then counted. Results. Compared the characteristics of LT photocatalyst with commercial P-25 photocatalyst, LT were shown higher activity than P-25. The LT coated experimental specimen surface had anatase crystal form, less than 20 nm of particle size and wide specific surface area. To evaluate the photocatalytic activity of specimens, methylene blue degradation reaction were used and about 5% of degradation rate were measured after 2 hours. The average contact angle was less than $20^{\circ}$ indicating that the LT photocatalyst had hydrophilicity. In the antifungal activity test for Candida albicans, 0% survival rate were measured within 30 minute after irradiation of UVA light. Conclusion. From the results reported above, it is concluded that the UVA-LT photocatalytic reaction have an antifungal effect on the denture surface Candida albicans, and so that could be applicable to the clinical use as a cleaning method.

Assessment of Acidogenic Potential for Dental Biofilms by Periodontal Health Condition (치주 건강 상태에 따른 치면세균막의 산 생성능력 평가에 대한 연구)

  • Min, Ji-Hyun;Yoon, Hong-Cheol;Kim, Jong-Kwan;Kang, Si-Mook;Kim, Baek-Il
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.202-208
    • /
    • 2015
  • The aim of this retrospective study was to evaluate the relationship between periodontal health condition and the results of a new method such as Cariview which could evaluate the acidity of dental biofilms. Fifty four subjects more than 20 years old were selected for the candidates of this study. The periodontal health conditions of the candidates were divided into 4 groups according to the assessment of X-ray and Quantitative Light-induced Fluorescence-Digital (QLF-D; Inspektor Research Systems BV) images; gingivitis, slight periodontitis, moderate periodontitis, severe periodontitis. The biofilm acidogenicity of each subject was examined using Cariview (All in ONE BIO) according to manufacturer's instruction, and the Cariview score was calculated. The mean differences of Cariview score between 4 groups of periodontal health condition were examined by ANCOVA test with the covariance of decayed, missing, and filled teeth (DMFT) index. As a result, the mean Cariview score was different, however it was not significantly different from the 4 groups (p=0.12). The mean score was the lowest in the gingivitis group ($40.54{\pm}11.01$), and the highest in slight periodontitis group ($57.26{\pm}20.51$). In conclusion, the significant mean differences were not confirmed in Cariview score according to the periodontal health condition.

Interpreting Bounded Rationality in Business and Industrial Marketing Contexts: Executive Training Case Studies (집행관배훈안례연구(阐述工商业背景下的有限合理性):집행관배훈안례연구(执行官培训案例研究))

  • Woodside, Arch G.;Lai, Wen-Hsiang;Kim, Kyung-Hoon;Jung, Deuk-Keyo
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.3
    • /
    • pp.49-61
    • /
    • 2009
  • This article provides training exercises for executives into interpreting subroutine maps of executives' thinking in processing business and industrial marketing problems and opportunities. This study builds on premises that Schank proposes about learning and teaching including (1) learning occurs by experiencing and the best instruction offers learners opportunities to distill their knowledge and skills from interactive stories in the form of goal.based scenarios, team projects, and understanding stories from experts. Also, (2) telling does not lead to learning because learning requires action-training environments should emphasize active engagement with stories, cases, and projects. Each training case study includes executive exposure to decision system analysis (DSA). The training case requires the executive to write a "Briefing Report" of a DSA map. Instructions to the executive trainee in writing the briefing report include coverage in the briefing report of (1) details of the essence of the DSA map and (2) a statement of warnings and opportunities that the executive map reader interprets within the DSA map. The length maximum for a briefing report is 500 words-an arbitrary rule that works well in executive training programs. Following this introduction, section two of the article briefly summarizes relevant literature on how humans think within contexts in response to problems and opportunities. Section three illustrates the creation and interpreting of DSA maps using a training exercise in pricing a chemical product to different OEM (original equipment manufacturer) customers. Section four presents a training exercise in pricing decisions by a petroleum manufacturing firm. Section five presents a training exercise in marketing strategies by an office furniture distributer along with buying strategies by business customers. Each of the three training exercises is based on research into information processing and decision making of executives operating in marketing contexts. Section six concludes the article with suggestions for use of this training case and for developing additional training cases for honing executives' decision-making skills. Todd and Gigerenzer propose that humans use simple heuristics because they enable adaptive behavior by exploiting the structure of information in natural decision environments. "Simplicity is a virtue, rather than a curse". Bounded rationality theorists emphasize the centrality of Simon's proposition, "Human rational behavior is shaped by a scissors whose blades are the structure of the task environments and the computational capabilities of the actor". Gigerenzer's view is relevant to Simon's environmental blade and to the environmental structures in the three cases in this article, "The term environment, here, does not refer to a description of the total physical and biological environment, but only to that part important to an organism, given its needs and goals." The present article directs attention to research that combines reports on the structure of task environments with the use of adaptive toolbox heuristics of actors. The DSA mapping approach here concerns the match between strategy and an environment-the development and understanding of ecological rationality theory. Aspiration adaptation theory is central to this approach. Aspiration adaptation theory models decision making as a multi-goal problem without aggregation of the goals into a complete preference order over all decision alternatives. The three case studies in this article permit the learner to apply propositions in aspiration level rules in reaching a decision. Aspiration adaptation takes the form of a sequence of adjustment steps. An adjustment step shifts the current aspiration level to a neighboring point on an aspiration grid by a change in only one goal variable. An upward adjustment step is an increase and a downward adjustment step is a decrease of a goal variable. Creating and using aspiration adaptation levels is integral to bounded rationality theory. The present article increases understanding and expertise of both aspiration adaptation and bounded rationality theories by providing learner experiences and practice in using propositions in both theories. Practice in ranking CTSs and writing TOP gists from DSA maps serves to clarify and deepen Selten's view, "Clearly, aspiration adaptation must enter the picture as an integrated part of the search for a solution." The body of "direct research" by Mintzberg, Gladwin's ethnographic decision tree modeling, and Huff's work on mapping strategic thought are suggestions on where to look for research that considers both the structure of the environment and the computational capabilities of the actors making decisions in these environments. Such research on bounded rationality permits both further development of theory in how and why decisions are made in real life and the development of learning exercises in the use of heuristics occurring in natural environments. The exercises in the present article encourage learning skills and principles of using fast and frugal heuristics in contexts of their intended use. The exercises respond to Schank's wisdom, "In a deep sense, education isn't about knowledge or getting students to know what has happened. It is about getting them to feel what has happened. This is not easy to do. Education, as it is in schools today, is emotionless. This is a huge problem." The three cases and accompanying set of exercise questions adhere to Schank's view, "Processes are best taught by actually engaging in them, which can often mean, for mental processing, active discussion."

  • PDF

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.

THE BONDING DURABILITY OF RESIN CEMENTS (레진시멘트의 접착 내구성에 관한 연구)

  • Cho, Min-Woo;Park, Sang-Hyuk;Kim, Jong-Ryul;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.343-355
    • /
    • 2007
  • The objectives of this study was to evaluate the durability of 4 resin cements by means of microtensile bond strength test combined with thermocycling method and fractographic FE-SEM analysis. Experimental groups were prepared according to thermocycling (0, 1,000, 5,000) and the kind of resin cements, those were Variolink II, Multilink, Panavia F 2.0, Rely X Unicem. Flat dentin surfaces were created on mid-coronal dentin of extracted third molars. Then fresh dentin surface was grounded with 320-grit silicon carbide abrasive papers to create uniform smear layers. Indirect composite block (Tescera, Bisco Inc., Schaumburg, IL, USA) was fabricated ($12\;{\times}\;12\;{\times}\;6\;mm^3$). It's surface for bonding to tooth was grounded with silicon carbide abrasive papers from 180- to 600-grit serially, then sandblasted witk $20\;-\;50\;{\mu}m$ alumina oxide. According to each manufacturer's instruction, dentin surface was treated and indirect composite block was luted on it using each resin cement. For Rely X Unicem, dentin surface was not treated. The bonded tooth-resin block were stored in distilled water at $37^{\circ}C$ for 24 hours. After thermocycling, the bonded tooth-resin block was sectioned occluso-gingivally to 1.0 mm thick serial slabs using all Isomet slow-speed saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA). These sectioned slabs were further sectioned to $1.0\;{\times}\;1.0\;mm^2$ composite-dentin beams. The specimens were tested with universal testing machine (EZ-Test, Shimadzu, Japan) at a crosshead speed of 1.0 mm/min with maximum load of 500 N. The data was analyzed using one-way ANOVA and Duncan's multiple comparison test at $p\;{\leq}\;0.05$ level. Within the limited results, we conclude as follows; 1. The bond strength of Variolink II was evaluated the highest among experimental groups and was significantly decreased after 1,000 thermocycling (p < 0.05). 2. The bond strength of Multilink was more affected by thermocycling than the other experimental groups and significantly decreased after 1,000 thermocycling (p < 0.05). 3. Panavia F 2.0 and Rely X Unicem showed the gradually decreased tendency of microtensile bond strength according to thermocycling but there was no significant difference (p > 0.05). 4. Adhesive based-resin cements showed lower bond strength with or without thermocycling than composite based-resin cements. 5. Variolink II & Multilink showed high bond strength and mixed failure, which was occurred with a thin layer of luting resin cement before thermocycling and gradually increased adhesive failure along the dentin surface after thermocycling. The bonding performance of resin cement can be affected by application procedure and chemical composition. Composite based-resin cement showed higher bond strength and durability than adhesive based-resin cement.

A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment (기성 지대주와 맞춤형 CAD-CAM 지대주의 적합 및 나사 안정성 비교)

  • Kim, Jong-Wook;Heo, Yu-Ri;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.276-283
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the fit and screw joint stability between Ready-made abutment and CAD-CAM custom-made abutment. Materials and methods: Osstem implant system was used. Ready-made abutment (Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea), CAD-CAM custom-made abutment (CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea) and domestically manufactured CAD-CAM custom-made abutment (Myplant, Raphabio Co., Seoul, Korea) were fabricated five each and screws were provided by each company. Fixture and abutments were tightening with 30Ncm according to the manufacturer's instruction and then preloding reverse torque values were measured 3 times repeatedly. Kruskal-Wallis test was used for statistical analysis of the preloading reverse torque values (${\alpha}=.05$). After specimens were embedded into epoxy resin, wet cutting and polishing was performed and FE-SEM imaging was performed, on the contact interface. Results: The pre-loading reverse torque values were $26.0{\pm}0.30Ncm$ (ready-made abutment; Transfer abutment) and $26.3{\pm}0.32Ncm$ (CAD-CAM custom-made abutment; CustomFit abutment) and $24.7{\pm}0.67Ncm$ (CAD-CAM custom-made abutment; Myplant). The domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) presented lower pre-loading reverse torque value with statistically significant difference than that of the ready-made abutment (Transfer abutment) and CAD-CAM custom-made abutment (CustomFit abutment) manufactured from the same company (P=.027) and showed marginal gap in the fixture-abutment interface. Conclusion: Within the limitation of the present in-vitro study, in domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) showed lower screw joint stability and fitness between fixture and abutment.

Prevalence of Feline Leukemia Virus Infection in Cats in Bangladesh (방글라데시의 고양이 백혈병 바이러스의 감염율 조사)

  • Rahman, Siddiqur;Bhuiyan, Salauddin;Islam, Taohidul;Nahar, Azimun;Sarker, Roma Rani;Alam, Emtiaj;Chakrabarty, Amitavo;Sarker, Abu Sayed;Akhter, Laila;Chae, Joon-Seok
    • Journal of Veterinary Clinics
    • /
    • v.31 no.1
    • /
    • pp.1-5
    • /
    • 2014
  • Feline leukemia virus (FeLV) is a retrovirus that represents one of the most common and important infectious diseases of cats worldwide and it is responsible for more deaths among cats than any other infectious diseases. Prevalence data are necessary to define prophylactic, management and therapeutic measures for stray, feral and owned cats which are lacking in Bangladesh. The study was carried out to determine the prevalence of FeLV infection in Mymensingh district of Bangladesh using RapiGEN$^{(R)}$ FeLV Ag Test Kit (RapiGEN$^{(R)}$ Inc., Republic of Korea), a rapid one-step immunochromatographic assay. Blood samples from total 130 cats (23 owned cats and 107 unowned cats) were collected and tested following the manufacturer's instruction. An overall prevalence of FeLV infection was 1.54% (2/130). Prevalence was found 1.79% (2/112) on Day 0-up to one year aged cats (young) but no positive case was found in above 1 year (Adult) aged group. In male and female cats, the prevalence was 1.72% (1/58) and 1.39% (1/72), respectively. In un-owned cats the prevalence was 1.87%. Positive cases to FeLV were found only in clinically sick cats. No significant relationship was found according to age, sex, ownership status and health status. To the best of our knowledge this is the first report of the prevalence of FeLV infection in Bangladesh using RapiGEN$^{(R)}$ FeLV test kits which is very much effective because it is easy to apply, less expensive and quick screening of such type of infection.

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

ENAMEL ADHESION OF LIGHT-AND CHEMICAL-CURED COMPOSITES COUPLED BY TWO STEP SELF-ETCH ADHESIVES (2단계 자가 산부식 접착제와 결합된 광중합과 화학중합 복합레진의 법랑질 접착)

  • Han, Sae-Hee;Kim, Eun-Soung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.169-179
    • /
    • 2007
  • This study was to compare the microshear bond strength $({\mu}SBS)$ of light- and chemically cured composites to enamel coupled with four 2-step self-etch adhesives and also to evaluate the incompatibility between 2-step self-etch adhesives and chemically cured composite resin. Crown segments of extracted human molars were cut mesiodistally, and a 1 mm thickness of specimen was made. They were assigned to four groups by adhesives used: SE group (Clearfil SE Bond) AdheSE group (AdheSE), Tyrian group (Tyrian SPE/One-Step Plus), and Contax group (Contax) Each adhesive was applied to a cut enamel surface as per the manufacturer's instruction. Light-cured (Filtek Z250) or chemically cured composite (Luxacore Smartmix Dual) was bonded to the enamel of each specimen using a Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The mean ${\mu}SBS$ (n=20 for each group) was statistically compared using two-way ANOVA, Tukey HSD, and t test at 95% level. Also the interface of enamel and composite was evaluated under FE-SEM. The results of this study were as follows ; 1. The ${\mu}SBS$ of the SE Bond group to the enamel was significantly higher than that of the AdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin (p < 0.05). 2. There was not a significant difference among the hdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin. 3. The ${\mu}SBS$ of the light-cured composite resin was significantly higher than that of the chemically cured composite resin when same adhesive was applied to the enamel (p < 0.05). 4. The interface of enamel and all 2-step self-etch adhesives showed close adaptation, and so the incompatibility of the chemically cured composite resin did not show.