• Title/Summary/Keyword: Manual Measurement

Search Result 453, Processing Time 0.028 seconds

Effect of surface finishing treatments on the color stability of CAD/CAM materials

  • Ozen, Funda;Demirkol, Nermin;Oz, Ozge Parlar
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.150-156
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the effect of different surface finishing processes on the color stabilities of lithium disilicate glass-ceramics, zirconia-reinforced lithium silicate ceramics, and resin nanoceramics after artificial ageing. MATERIALS AND METHODS. 216 samples were prepared from 3 different CAD/CAM materials (LAVA Ultimate, IPS e.max CAD, VITA Suprinity) with A1 HT color at a size of 14 × 12 mm and a thickness of 0.5 ± 0.05 mm. Color measurements of the samples were performed with a spectrophotometer using color parameters and CIE Lab color system on a gray backing between baseline color and after 5000 cycles of artificial ageing in 4 stages (i.e. the first measurement before the treatment, the second measurement after polishing, the third measurement after cement application, and the fourth measurement after artificial ageing). The results were evaluated using the Variance analysis and Fisher's LSD test. RESULTS. Resin nanoceramics (LU) exhibited higher color change values than zirconia-reinforced lithium silicate (VS) and lithium disilicate (EC) ceramics after artificial ageing. Manual polishing and glazing resulted in similar color change for LU and VS (P>.05). In the EC group, glazing provided statistically different results as compared to the manual polishing and control groups (P<.05). Among the ceramic groups, color change values of the subgroup, which was treated by glazing, of the zirconia-reinforced lithium silicate (VS) and lithium disilicate (EC) samples were below the clinically acceptable level (ΔE < 3.5). CONCLUSION. The lowest color change for all stages was observed in Vita Suprinity.

Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles (외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도)

  • Kim, Chang-Yong;Choi, Jong-Duk;Kim, Suhn-Yeop;Oh, Duck-Won;Kim, Jin-Kyung
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

The Effects of Shoulder Mulligan Taping and Repeated Measurements on Wrist Flexor Muscle Activity and Grip Strength in Forward Head Posture (전방머리자세 대상자에게 어깨관절 멀리건테이핑 적용이 손목굽힘근의 근활성도와 파악력에 미치는 영향)

  • Oh, Kang-o;Park, Su-hyung;Kim, Dong-woo;Baek, Yong-hyeon;Choi, Su-hong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.1-7
    • /
    • 2018
  • Background: This study was carried out to investigate the effect of mulligan taping group and repeated measurement group on muscle activity and grip strength of adult with forward head posture. Methods: Thirty adults with forward head posture were randomly assigned to each of 15 mulligan taping and repeat measurement groups. The mulligan taping group measured the pre-test and post-test muscle activity and the grip strength three times and compared the mean values. The repeat group was repeatedly measured and measured before and after the experiment, The collected data were analyzed using SPSS statistical program. Results: There was no significant difference between mulligan taping group and repeated measurement group in changes of muscle activity. There was a significant difference between mulligan taping group and repeated measurement group in changes of grip strength. Conclusions: Mulligan taping was applied to an adult with forward head posture, there was no significant change in muscle activity of flexor carpi radialis and palmaris longus, but it seems to improve hand function by re-aligned of nearby muscles by maintaining scapular stability.

Comparison of the Balancing Capacity and Strength of Taping for the Knee Joint and Repeated Measurements (무릎관절 멀리건 테이핑이 균형능력과 각근력에 미치는 효과와 측정의 반복에 의한 효과 비교)

  • Park, Bo-hyun;Choi, Su-hong;Kim, Sung-joong;Park, Su-hyung;Oh, Kang-o
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2018
  • Background: The purpose of this study was to compare the effects of mulligan taping on knee joints on balance ability and strength with repeated measurements. Methods: Seventeen patients were randomly assigned to the 8 taping group and the 9 repeat measurement group. To measure the balance ability, fall risk assessment equipment was used, and the measurement of the muscle strength was performed by using the equipment of the same company. Results: Balanced abilities and muscle strength were increased in groups with taping only after Mulligan taping. Conclusions: The application of mulligan taping did not have the effect of stimulating the inherent receptive sensation. However, active grouping of the knee joint taping only, and muscle strength and muscle strength were increased. It increases the stability and activity of the muscles that operate on the balance of the active knee joint and muscle strength, thereby enhancing exercise prevention and prevention performance and exercise performance.

Development of a Computer Measurement and Control System for Rough Rice Drying by Natural Air (미곡(米穀)의 상온통풍건조(常温通風乾燥)를 위한 컴퓨터 계측(計測) 및 제어(制御)시스템 개발)

  • Kim, T.K.;Chang, D.I.;Kim, M.S.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.4
    • /
    • pp.46-55
    • /
    • 1988
  • The objective of this study was to develop a computer measurement and control system which enable it possible to manage the natural air rough rice drying and storage properly and safely. The following contents of work were taken in this study in order to fulfill the above goal: 1) Design and construction of measurement system which can measure the rough rice drying conditions automatically and transfer them to computer system for data processing. 2) Development of a management software which can determine the need of fan operation by the analysis of drying and/or storage conditions. 3) Design and construction of a control system which deliver the computer decision of fan operation and make it on and off. 4) Technical and economical analysis of the computer measurement and control system development by the comparison experiments of the computer management and of the manual.

  • PDF

A Study on Real-time Quality Evaluation Method of Bibliographic Database (실시간 서지데이터베이스 평가방법에 관한 연구)

  • 노경란;권오진;유현종;문영호;홍성화
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.4
    • /
    • pp.76-84
    • /
    • 2002
  • The conventional database evaluation method is carried out by the way in which the person in charge of each specialty database(DB manager) composes the evaluation sheets for corretionㆍrevision on the already-constructed database in a manual method and carries out the measurement and re-education of DB workers based upon it. As a result, that way consumes much time on career information and measurement works about DB workers, causing low time and cost efficiency and lack of systematic management of DB workers, resulting in becoming the hindrance factor of databases quality improvement. This research provides on-line, red-time results of measurements about the efficiency of DB production and DB workers by combining the static measurement with dynamic measurement by DB manager, both of which utilize the System. Therefore, the DB manager can contribute to the improvement of DB quality by determining the continuation of DB production by DB workers or carrying out the re-education of DB workers without being affected by time or spacial constraints.

  • PDF

The Design and Implementation of Mouse Activity Measurement System using Infrared Sensor

  • Kwak, Ho-Young;Huh, Jisoon;Lee, Won Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.81-89
    • /
    • 2016
  • In this paper, we design and implement a mouse movement measurement system using an infrared sensor called MAMS (Mouse Activity Measurement System). Unlike existing systems, MAMS can measure movements between IREDs. MAMS is removable allowing convenient portability and is also low cost. MAMS automatically measures mouse activity during a pre-set time interval. Since the measured data can be easily stored in a computer system, it is much simpler and more efficient than the Ugo 47420 model. Moreover, MAMS can be used in medical and veterinary field to eliminate manual observations.

Cyclic Measurement System for Evaluating Organic Light Emitting Diode Devices (유기 발광 다이오드 소자의 성능·수명 평가를 위한 순환 계측 시스템)

  • Park, Il-Hoo;Na, In-Yeob;Joo, Hyeonpil;Kim, Gyu-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.1
    • /
    • pp.50-53
    • /
    • 2018
  • Cyclic measurement system using relay circuit for organic light emitting diode (OLED) was demonstrated. The OLED characterization such as current-voltage, impedance, and capacitance-voltage is performed in sequence, repetitively and automatically under full control of the personnel computer (PC) without changing the connection of cables. Owing to in situ degradation by cyclic measurement, the time dependence of the data can give good information on the reliability factor of the OLED devices. Therefore, both performance and reliability of the OLEDs can be evaluated, with no manual operation during the entire process.

An Evaluation of the Reliability and Validity of the Automatic Pennation Angle Measuring Program (깃각 자동측정 프로그램의 신뢰도와 타당도 평가)

  • Kim, Jong-Soon
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.329-337
    • /
    • 2019
  • Purpose: Ultrasound imaging is commonly used to measure the pennation angle of human skeletal muscles in vivo. However, manual assessment of the pennation angle using ultrasound images is subjective and time-consuming and requires a high level of examiner skill. The architectural analysis of human skeletal muscles is thus challenging. Automated approaches using image processing techniques are therefore required to estimate the pennation angle in ultrasound images. The purpose of this study was thus to assess the intra-tester and inter-tester reliability and validity of the pennation angle using an automatic measurement program. Methods: Twenty-two healthy young adults (mean age = 22.55 years) with no medical history of neurological or musculoskeletal disorders voluntarily participated in this study. Ultrasound imaging was used to measure the pennation angle of the gastrocnemius muscle at rest. One examiner acquired images from all the participants. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC) to estimate reliability. Validity was measured using Pearson's correlation coefficient. Results: The intra-rater reliability was excellent for the automatic pennation angle measuring program and the manual pennation angle assessment method (ICC>0.95). The inter-rater reliability was also excellent for both methods (ICC>0.93). All the correlation coefficients for the automatic pennation angle measuring program and the manual pennation angle assessment method were 0.79, which indicated a significantly positive correlation (p<0.05). Conclusion: Pennation angle measurement using the automatic pennation angle measuring program showed acceptable reliability and validity. This study therefore demonstrated that the automatic measuring program was able to automatically measure the pennation angle of skeletal muscles using ultrasound images, and thus made it easy to investigate skeletal muscle architecture.

Automatic Hand Measurement System from 2D Hand Image for Customized Glove Production

  • Han, Hyun Sook;Park, Chang Kyu
    • Fashion & Textile Research Journal
    • /
    • v.18 no.4
    • /
    • pp.468-476
    • /
    • 2016
  • Recent advancements in optics technology enable us to realize fast scans of hands using two-dimensional (2D) image scanners. In this paper, we propose an automatic hand measurement system using 2D image scanners for customized glove production. To develop the automatic hand measurement system, firstly hand scanning devices has been constructed. The devices are designed to block external lights and have user interface to guide hand posture during scanning. After hands are scanned, hand contour is extracted using binary image processing, noise elimination and outline tracing. And then, 19 hand landmarks are automatically detected using an automatic hand landmark detection algorithm based on geometric feature analysis. Then, automatic hand measurement program is executed based on the automatically extracted landmarks and measurement algorithms. The automatic hand measurement algorithms have been developed for 18 hand measurements required for custom-made glove pattern making. The program has been coded using the C++ programming language. We have implemented experiments to demonstrate the validity of the system using 11 subjects (8 males, 3 females) by comparing automatic 2D scan measurements with manual measurements. The result shows that the automatic 2D scan measurements are acceptable in the customized glove making industry. Our evaluation results confirm its effectiveness and robustness.