• Title/Summary/Keyword: Manual Measurement

Search Result 453, Processing Time 0.029 seconds

Development of a Surface-Strain Measurement System Using the Image Processing Technique (화상처리법을 이용한 곡면변형률 측정 시스템의 개발)

  • Han, Sang-Jun;Kim, Yeong-Su;Kim, Hyeong-Jong;O, Su-Ik
    • Transactions of Materials Processing
    • /
    • v.7 no.6
    • /
    • pp.575-585
    • /
    • 1998
  • An automated surface-strain measuring system using the image processing technique is developed in the present study which consists of the hardware to capture and to display digital images. and the software to calculate the 3-D informations of grid points from two views. New or improved algorithms for the mapping and establishing correspondence of grid points and elements the camera calibration and the subpixel measurement of grid points are implemented. As an application of the present system the surface-strains of deformed blanks in the limitting dome height test the square cup deep-drawing and punch stretching to obtain the forming limit diagram are measured. The results are com-pared with those obtained by conventional manual methods.

  • PDF

The Development of 3D based On-Machine Measurement Operating System (3D 기반의 기상측정 운영시스템 개발)

  • 윤길상;최진화;조명우;김찬우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.145-152
    • /
    • 2004
  • This paper proposed efficient manufacturing system using the OMM (on-machine measurement) system. The OMM system is software based 3D modeler for inspection on machine and it is interfaced tool machine with RS232C. The software is composed of two inspection modules that one is touch probe operating module and the other is laser displacement sensor operating module. The module for touch probe has need of inspection feature that extracted it from CAD data. Touch probe moves to workpiece by three operating modes as follows: manual, general and automatic mode. The operating module of laser displacement sensor is used inspection for profile and very small hole. An Advantage of this inspection method is to be able to execute on-line inspection during machining or after it. The efficiency of proposed system which can predict and definite the machining errors of each process is verified, so the developed system is applied to inspect the mold-base(cavity, core).

An analysis of the measurements of the obesity using the code of Quantum Resonance Imprinting System(QRIS) with infusion and using the Free Radical Measurement(Ultra-weak Chemiluminescence) with soak in water regarding medicines which would be mostly used for the treatment of the obesity (비만 범용 처방(處方)에 대한 탕전후(湯煎後) 경락 기능 진단기(QRIS)의 비만 연관 Code측정 및 수침후(水浸後) Free Radical 측정기를 이용한 측정에 대한 고찰)

  • Kim, Jae-Joong;Lim, Hyung-Ho;Sun, Yu-Jin;Lee, Dong-Hoon
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.1 no.1
    • /
    • pp.83-90
    • /
    • 2000
  • Oryeong-San, Pangpungtongseong-San, Rangkyeoksanwha-Tang, Sipeemikwanjoong -Tang and Taeumjoui-Tang are not only examined using the code which are related to overweight in the QRIS but are also investigated the level of Free Radical using the Free Radical Measurement after steeping those 5 prescriptions in water. The results are as follows: 1. We indicated in the study of QRIS that 5 kinds of medicines which used most frequently In the treatment of the obesity appeared to affect the Immune system, spleen, kidneys, pancreas, the fatigue toxicity, TSH, and the metabolic disability but did not influence high on the contents of overweight and those of fatty cell, as well. in addition, there were no significant differences between the prescriptions as regards testosterone and progesterone. 2. In the Free Radical Measurement, Rangkyeoksanwha-Tang evaluated significantly high level of Free Radical, whereas others appear to have the similar level of Free Radical. These findings suggest that the treatment of the obesity affects particular body parts with respect to the control of overweight, although those medicines are not related directly to the areas(such as fatty cell Code), it is possible that they influence on the cure for the obesity. Furthermore, they indicate that with soaking prescription, Free Radical is not produced as much as we expected.

  • PDF

The Reliability and Relationships Between Thoracic Kyphosis, Postural Stiffness and Thoracic Rotation in Young Subjects (젊은 성인의 흉추후만지수 및 자세 경직도와 흉추회전각 간의 상관성과 신뢰도)

  • Jang, Hyun-Jeong;Kim, Suhn-Yeop;Kim, Myung-Jun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.18 no.2
    • /
    • pp.49-55
    • /
    • 2012
  • Background: The purposes of this study were to: 1) investigate the relation between thoracic kyphosis, postural stiffness and thoracic rotation and 2) the intra-rater reliability of the measurement methods for thoracic kyphosis and rotation angle. Methods: Thirty-nine young adults (13 males, 26 females) participated in the study. Thoracic kyphosis was measured using a Flexicurve while standing in their usual relaxed posture and then in their maximally erector posture. Index of kyphosis (IK) measures taken in the relaxed and maximally erect positions were used to estimate postural stiffness. Thoracic rotation range of motion (ROM) was measured using universal goniometer and inclinometer in two positions. The association between the magnitude of the IK and thoracic stiffness and thoracic rotation ROM was also examined. Reliability was determined using intra-class correlation coefficients (ICC). Results: When measured from the mean relaxed IK (${\pm}SD$) was 7.42 (${\pm}1.47$) and mean erect IK was 4.92 (${\pm}1.63$) and mean IK ratio was 1.66 (${\pm}.65$). The relaxed IK was significantly correlated with the range of motion thoracic rotation in two positions (r=.503~580, p<.01). Conclusion: Thoracic kyphosis in relaxed position was associated with the range of motion thoracic rotation. Thoracic kyphosis measurement with the Flexicurve and range of motion 2 techniques of thoracic rotation showed good reliablity and may be a useful measurement tool in clinical practice.

  • PDF

Prediction of Maximal Flexion Strength for Exercise Intensity Setting and Measurement in Elbow Joint (팔꿉관절 운동강도 설정 및 측정을 위한 최대굴곡력 예측)

  • Jang, Jee-Hun;Kim, Jae-Min;Kim, Yeon-Kyu;Kim, Jin-Chul;Cho, Tae-Yong;Kim, Yun-Jeong;Lee, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1628-1633
    • /
    • 2017
  • The purpose of this study was to identify the difference and correlation in elbow joint maximal flexion strength according to measurement methods and characteristics of muscular contraction, and to develop the predictive equation of elbow joint maximal flexion strength for the optimal exercise intensity setting and accurate measurement. Subjects were 30 male university students. Elbow joint maximal flexion strength of isokinetic contraction, isometric contraction at $75^{\circ}$ elbow joint flexion position, isotonic concentric 1RM, manual muscle strength (MMT) were measured with isokinetic dynamometer, dumbbell, and manual muscle tester. Pearson's r, linear regression equation, and multiple regression equation between variables were calculated. As a result, the highest value was isometric contraction. The second highest value was MMT. The third highest value was isokinetic contraction. 1RM was the lowest. Predictive equations of elbow joint maximal flexion strength between isometric and isokinetic contraction, between isometric contraction and 1RM, among isometric contraction, 1RM, and body weight were developed. In conclusion, 1RM and isokinetic elbow joint maximal flexion strength could be seemed to underestimate the practical elbow joint maximal flexion strength. And it is suggested that the developed predictive equations in this study should be useful in criteria- and goal-setting for resistant exercise and sports rehabilitation after elbow joint injury.

Development of Automated Guidance Tracking Sensor System Based on Laser Distance Sensors

  • Kim, Joon-Yong;Kim, Hak-Jin;Shim, Sung-Bo;Park, Soo-Hyun;Kim, Jung-Hun;Kim, Young-Joo
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.319-327
    • /
    • 2016
  • Purpose: Automated guidance systems (AGSs) for mobile farm machinery have several advantages over manual operation in the crop production industry. Many researchers and companies have tried to develop such a system. However, it is not easy to evaluate the performance of an AGS because there is no established device used to evaluate it that complies with the ISO 12188 standard. The objective of this study was to develop a tracking sensor system using five laser distance measurement sensors. Methods: One sensor-for long-range distance measurement-was used to measure travel distance and velocity. The other four sensors-for mid-range distance measurement-were used to measure lateral deviation. Stationary, manual driving, and A-B line tests were conducted, and the results were compared with the real-time kinematic differential global positioning system (RTK-DGPS) signal used by the AGS. Results: For the stationary test, the average error of the tracking sensor system was 1.99 mm, and the average error of the RTK-DGPS was 15.19 mm. For the two types of driving tests, the data trends were similar. A comparison of the changes in lateral deviation showed that the data stability of the developed tracking system was better. Conclusions: Although the tracking system was not capable of measuring long travel distances under strong sunlight illumination because of the long-range sensor's limitations, this dilemma could be overcome using a higher-performance sensor.

Effects of Dynamic Balance Exercise on Pain, Functional level, and Psychosocial Level in Patients with Non-specific Chronic Neck Pain (비특이성 만성 경부통 환자에게 적용한 동적 균형 운동이 통증과 기능적 수준, 심리사회적 수준에 미치는 효과)

  • Yu-hui Kwon;Suhn-yeop Kim
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.43-53
    • /
    • 2023
  • Background: Patients with neck pain develop instability due to muscle imbalance, decreased proprioception, and balance disorders. Studies have examined various exercise methods as treatment methods, but few studies have compared the effects of cervical stabilization exercise and dynamic balance exercise. The purpose of this study was to investigate the effects of dynamic balance exercise on pain, functional level, and psychosocial level in patients with non-specific chronic neck pain. Methods: Thirty-four non-specific chronic neck pain patients were randomly assigned to the experimental group (EG, n=17) and control group (CG, n=17); the cervical stabilization exercise and dynamic balance exercise program were applied to the EG; and only the cervical stabilization exercise program was applied to the CG. The intervention was conducted twice a week, for six weeks. Assessment items evaluated pain, dysfunction (Korean version neck disability index), range of motion, craniocervical flexion test, cervical deep flexor endurance test, and psychosocial level. Data analysis was performed using intention-to-treat analysis as assigned. To analyze differences in the items assessed in the two groups, we used a repeated measures analysis of variance with an interaction between group (EG, CG) and time point (baseline, 6 weeks, 12 weeks). Results: The endurance of the cervical flexor muscles between the group and the measurement point after intervention (p<.05). Both groups showed significantly improved endurance between time points after the intervention (p<.05), with the EG showing a greater change than the CG. None of the other measurement items differed in the pattern of change between measurement points. Conclusion: In conclusion, the EG applying a cervical stabilization exercise and a dynamic balance exercise experienced a significant difference in muscle endurance improvement compared to the CG. We propose an exercise intervention program that includes stabilization exercises and dynamic balance exercises for patients with chronic cervical pain who lack muscle endurance.

  • PDF

Automatic Inspection for LCD Panel Defect (LCD(Liquid Crystal Display) Panel의 결점 검사)

  • Lee Y.J.;Lee J.H.;Ko K.W.;Cho S.Y.;Lee J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.946-949
    • /
    • 2005
  • This paper deals with the algorithm development that inspects defects such as Bright Defect Dots, Dark Defect Dots, and Line Defect caused by the process of LCD(Liquid Crystal Display). While most of LCD production process is automated, the inspection of LCD panel and its appearance depends on manual process. So, the quality of the inspection is affected by the condition of worker. Especially, the more LCD size increases, the more the worker feels fatigued, which causes the probability of miss judgement. So, the automated inspection is required to manage the consistent quality of the product and reduce the production costs. In this paper, to solve these problems, we developed the imaging processing algorithm to inspect the defects in captured image of LCD. Experimental results reveal that we can recognize various types of defect of LCD with good accuracy and high speed.

  • PDF

An Approach to Measure Anthropometric Data of Simulated Human Hand Using Photogrammetry (시뮬레이션 환경에서 사진측량기법을 이용한 손 치수 측정 방법에 대한 연구)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.5
    • /
    • pp.511-517
    • /
    • 2016
  • Anthropometric data of the hand is one of the important issues for the product design related with hand and manual operation in terms of user-centered design. Direct measurement, which traditionally uses anthropometric measuring tool, has a few disadvantages in cumulation of measuring time, possible errors in raw data, doubtful reliability between inspectors. Newly introduced 3D scanning technology overcomes those disadvantages; however, another disadvantages, such as, hight cost and immovability, have been introduced. In this study, photogrammetric approach was introduced for the measurement of anthropometric data in hand. In order to minimize the possibility of error during direct and indirect measurement, a simulated object was used and effectiveness of photogrametric measurement was confirmed for the collection of anthropometric data in hand.

Standards for Ground Settlement Management when Reinforcing Ground in the Abandoned Mine (폐광지역 지반공사시 지반침하 관리를 위한 기준)

  • Yang, In Jae;Lee, Seung Ah;Baik, Dong Ho
    • Tunnel and Underground Space
    • /
    • v.27 no.5
    • /
    • pp.295-302
    • /
    • 2017
  • In this study, a new quantitative instrumentation and measurement standards applicable to the field of mining has been proposed to improve the problems of the current measurement practices that apply the measuring standards of the civil engineering field (road, railway, etc.). With the data coordination of the mine reclamation corporation, we collected data on ground subsidence in the abandoned mine area, and studied various techniques for establishing a new management reference value based on the manual measurement data measured in the field. As a result, new instrumentation and measurement standards is set up and proposed by using statistics like the average value, the third quartile, the 95% confidence, and the maximum value.