• Title/Summary/Keyword: Manual Diagnosis

Search Result 240, Processing Time 0.035 seconds

The Impact of M&L Psychotherapy on the Growth and Development of a Socially Disadvantaged Adolescent with Anxiety Disorders - Quantitative and Qualitative Analysis of a Single Case (M&L 심리치료가 불안장애를 가진 취약계층 청소년의 건강한 성장에 미치는 영향 - 단일증례의 양적, 질적 분석)

  • Jae-Wook Shin;Haegue Shin;Min-Joo Lee;Dong-Uk Kim;Hyo-Weon Suh;Hyung Won Kang
    • Journal of Oriental Neuropsychiatry
    • /
    • v.35 no.1
    • /
    • pp.115-140
    • /
    • 2024
  • Objectives: This study investigates the impact of M&L psychotherapy on an adolescent with anxiety disorders transitioning into adulthood, using a retrospective mixed-method approach. Methods: An adolescent with Diagnostic Statistical Manual of Mental Disorders (DSM)-5-diagnosed anxiety disorders underwent combined treatment with M&L psychotherapy and complex Korean medicine therapy over a period of approximately two years. Patient records tracked the diagnosis, treatments, and progress. In-depth interviews were also conducted. The study used a convergent parallel mixed-method approach, integrating quantitative analysis from psychological assessments, including the State-Trait Anxiety Inventory (STAI-X), the Core Seven Emotions Inventory-short form (CSEI-s), and the Minnesota Multiphasic Personality Inventory-2 (MMPI-2), with qualitative analyses of traditional Korean medicine counseling session notes, interviews, and other qualitative psychological assessments. Results: State anxiety decreased from 40 to 36, and trait anxiety decreased from 42 to 34. MMPI-2 L scale scores decreased slightly to 64T, whereas S scale scores increased to 62T, and FRS scores decreased to 70T from an initial score of 78T. Qualitative analysis revealed an increase in the MMPI-2 Es scale, identified as "subjectivity." Joy (喜) emerged as the highest emotional profile score in the CSEI-S. Scores for anger (怒), thought (思), fear (恐), and fright (驚) decreased, indicating improved negative emotions. Qualitatively, expressions of determination to "move forward" and "strengthen the mind" were noted, suggesting enhanced "lower danjeon (下丹田)." Conclusions: Integrating traditional Korean medicine treatment with M&L psychotherapy for a vulnerable adolescent with anxiety disorders demonstrated efficacy. Further research is warranted to substantiate the effectiveness of M&L psychotherapy and advocate for its wider adoption in mainstream practice.

A Validation Study of the Korean Version of Social Communication Questionnaire (한국어판 사회적 의사소통 설문지 타당화 연구)

  • Kim, Joo-Hyun;Sunwoo, Hyun-Jung;Park, Su-Bin;Noh, Dong-Hyun;Jung, Yeon Kyung;Cho, In-Hee;Cho, Soo-Churl;Kim, Bung-Nyun;Shin, Min-Sup;Kim, Jae-Won;Park, Tae-Won;Son, Jung-Woo;Chung, Un-Sun;Yoo, Hee Jeong
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.26 no.3
    • /
    • pp.197-208
    • /
    • 2015
  • Objectives : The purposes of this study were to examine the reliability and validity of the Korean version of Social Communication Questionnaire (K-SCQ) and to determine cut-off scores for diagnosis of autism spectrum disorder (ASD). Methods : A total of 166 subjects with ASD and their 186 unaffected siblings were recruited through child psychiatry clinics of university hospitals. Board certified child psychiatrists screened all probands suspected to have ASD based on the Diagnostic and Statistical Manual of Mental Disorders, fourth edition. To confirm the diagnoses, the Korean versions of the Autism Diagnostic Observation Schedule and the Autism Diagnostic Interview-Revised (K-ADI-R) were administered to all the subjects. All parents completed the K-SCQ and Social Responsiveness Scale (SRS). The non-ASD siblings were evaluated with the same instruments as the probands with ASD. We performed a factor analysis to examine the structure of K-SCQ. For testing the validity of K-SCQ, we compared the difference in Lifetime and Current scores of probands with ASD and their non-ASD siblings using t-test and analysis of covariance. Correlations between the K-SCQ and other measurements of ASD symptomatology, including K-ADI-R totals and domain scores and SRS, were examined. Receiver operation characteristic curve analysis was performed to extract cutoff scores discriminating affection status. Results : Four factors were extracted through factor analysis of K-SCQ ; 1) social relation and play, 2) stereotyped behavior, 3) social behavior, and 4) abnormal language. Cronbach's internal consistency was .95 in K-SCQ Lifetime, and .93 in K-SCQ Current. There were significant differences in total score of K-SCQ, both in Lifetime and Current between the ASD group and non-ASD siblings group (p<.05). K-SCQ scores were significantly correlated with K-ADI-R subdomain scores and SRS total scores (p<.05). The best-estimate cut-off scores of K-SCQ for diagnosis of ASD were 12 for 48 months and over, and 10 for below 47 months. Conclusion : Our findings suggest that the K-SCQ is a reliable and valid instrument for screening autistic symptoms in the Korean population. Lower cut-off scores than the original English version might be considered when using it as a screening instrument of ASD.

Clinical Significance of Immature Reticulocyte Fraction and Reticulocyte Cellular Indices in Pediatric Anemia Patients (망상적혈구 지수 및 미성숙망상적혈구 분획의 소아 빈혈에서의 임상적 의의)

  • Seo, Young;Jung, Hye Lim;Shim, Jae Won;Kim, Deok Su;Shim, Jeong Yeon;Park, Moon Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.3
    • /
    • pp.284-291
    • /
    • 2005
  • Purpose : Flow cytometric automated reticulocyte analysis is a superior method to manual reticulocyte counting, with respect to precision and sensitivity. Furthermore, flow cytometric analysis is able to measure immature reticulocyte fraction(IRF) and reticulocyte cellular indices(RCI : cell hemoglobin content : CHr, mean cell volume : MCVr, cell hemoglobin concentration mean : CHCMr, distribytion width : RDWr, HDWr, CHDWr). In this study, we investigated the mean values and clinical significances of IRF and RCI in healthy children and pediatric anemia patients. Methods : IRF and RCI were measured with an automated blood cell analyzer, ADVIA 120(Bayer, USA) using oxazine 750 dye, in 57 healthy children and 61 children with anemia. The anemia group consisted of 27 iron deficiency anemia(IDA) patients and 34 patients with anemia associated with acute infection(AAI). We compared the mean values of IRF and RCI in the control group classified according to age, between anemia groups and the control group, and between the IDA group and the AAI group. Results : For the normal control group, the mean values of IRF, CHr, MCVr and HDWr were higher in neonates when compared to older children. The mean values of IRF and RDWr were significantly higher, and the mean values of CHr and CHCMr were significantly lower in the IDA group when compared to the control group. The mean value of IRF was significantly higher, and the mean value of CHDWr was significantly lower in the AAI group when compared to the control group. The mean values of IRF, CHr and CHCMr were significantly lower in the IDA group when compared to the AAI group. Conclusion : We could determine the normal mean values of IRF and RCI in healthy children classified according to age for understanding of hematopoietic response differences according to age. The evaluation of IRF and RCI by automated reticulocyte analyzer seemed to be accurate and clinically useful for the early diagnosis of anemia and the differentiation of IDA from AAI.

Usefulness of modified ambu® in patients who need artificial ventilation (인공 환기가 필요한 환자에서 변형된 수동식 인공호흡기(Ambu®)의 유용성)

  • Ha, Kee Soo;Moon, Il Hong;Lee, Hee Sun;Shin, Dong Han;Eun, So Hee;Eun, Baik-Lin;Hong, Young Sook;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1194-1201
    • /
    • 2006
  • Purpose : The comatose mentality can be catastrophic, especially if the condition is severe or the duration is prolonged. Therefore, delayed diagnosis can result in a poor outcome or death. The best radiologic modality to differentiate from cerebral lesions in patients suffering from cerebral diseases is magnetic resonance imaging (MRI) rather than computed tomography (CT). Special apparatuses with metal materials such as ventilators, and cardiac pacemakers belonging to patients cannot be located in the magnetic field. We aimed to exhibit the possibility of examining MRI, maintaining ventilation at a relative long distance by means of modified $Ambu^{(R)}$. Methods : Self-inflating bags as a sort of a manual ventilator, connected with relatively long extension tubes instead of mechanical ventilators, were adopted to obtain MRI. PVC (polyvinyl chloride) extension tubes had different lengths and diameters. Lengths were 1, 2, and 3 cm and diameters were 15, and 25 mm. The work of breathing and expiratory changes of expiratory tidal volume (TVe), minute volume of expiration (MVe), peak inspiratory pressure (PIP) were measured by use of the mechanical ventilator, $Servoi^{(R)}$, as the alteration of TVi (inspiratory tidal volume), extension tube lengths and diameters with other values fixed. Results : Measured TVe and MVe by ventilator were the same values with control at every TVi, regardless of extension tube lengths and diameters, but PIP were increased with the rise of TVi, tube lengths, with decline of tube diameters, these were statistically significant. Conclusion : MRI examination can be carried out with a self-inflating bag connected with an extension tube at a long distance in patients who need artificial ventilation.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

The Study of patient rotation angle to get the scapular true lateral image in scapular lateral projection (견갑골 측방향 촬영에서 견갑골 정측면상을 얻기 위한 환자의 회전각도에 관한 연구)

  • Park, Ki-Bong;Kang, In-Hyi;Choi, Nam-Kil;Jang, Young-Il;Jeon, Ju-Seob
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.203-209
    • /
    • 2005
  • Objective True lateral scapular image was very important to diagnosis the scapular fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapular true lateral in Korean. Subjects and Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine anteroposterior projection taken with $32^{\circ}$, $37^{\circ}$, $42^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlab of vertebral border and axillary border of scapular as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor. Results $32^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $37^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $42^{\circ}$trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. Conclusions There was no result of trunk rotation angle to radiograph the true scapular lateral image up to date. This studies were summarized as follows; Adaptation of $37^{\circ}$ trunk rotation was the best to show the true scapular lateral image in Korean. Our results were very useful to get the true scapular lateral images in clinic.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF

A Study for Improvement of Nursing Service Administration (병원 간호행정 개선을 위한 연구)

  • 박정호
    • Journal of Korean Academy of Nursing
    • /
    • v.3 no.1
    • /
    • pp.13-40
    • /
    • 1972
  • Much has teed changed in the field of hospital administration in the It wake of the rapid development of sciences, techniques ana systematic hospital management. However, we still have a long way to go in organization, in the quality of hospital employees and hospital equipment and facilities, and in financial support in order to achieve proper hospital management. The above factors greatly effect the ability of hospitals to fulfill their obligation in patient care and nursing services. The purpose of this study is to determine the optimal methods of standardization and quality nursing so as to improve present nursing services through investigations and analyses of various problems concerning nursing administration. This study has been undertaken during the six month period from October 1971 to March 1972. The 41 comprehensive hospitals have been selected iron amongst the 139 in the whole country. These have been categorized according-to the specific purposes of their establishment, such as 7 university hospitals, 18 national or public hospitals, 12 religious hospitals and 4 enterprise ones. The following conclusions have been acquired thus far from information obtained through interviews with nursing directors who are in charge of the nursing administration in each hospital, and further investigations concerning the purposes of establishment, the organization, personnel arrangements, working conditions, practices of service, and budgets of the nursing service department. 1. The nursing administration along with its activities in this country has been uncritical1y adopted from that of the developed countries. It is necessary for us to re-establish a new medical and nursing system which is adequate for our social environments through continuous study and research. 2. The survey shows that the 7 university hospitals were chiefly concerned with education, medical care and research; the 18 national or public hospitals with medical care, public health and charity work; the 2 religious hospitals with medical care, charity and missionary works; and the 4 enterprise hospitals with public health, medical care and charity works. In general, the main purposes of the hospitals were those of charity organizations in the pursuit of medical care, education and public benefits. 3. The survey shows that in general hospital facilities rate 64 per cent and medical care 60 per-cent against a 100 per cent optimum basis in accordance with the medical treatment law and approved criteria for training hospitals. In these respects, university hospitals have achieved the highest standards, followed by religious ones, enterprise ones, and national or public ones in that order. 4. The ages of nursing directors range from 30 to 50. The level of education achieved by most of the directors is that of graduation from a nursing technical high school and a three year nursing junior college; a very few have graduated from college or have taken graduate courses. 5. As for the career tenure of nurses in the hospitals: one-third of the nurses, or 38 per cent, have worked less than one year; those in the category of one year to two represent 24 pet cent. This means that a total of 62 per cent of the career nurses have been practicing their profession for less than two years. Career nurses with over 5 years experience number only 16 per cent: therefore the efficiency of nursing services has been rated very low. 6. As for the standard of education of the nurses: 62 per cent of them have taken a three year course of nursing in junior colleges, and 22 per cent in nursing technical high schools. College graduate nurses come up to only 15 per cent; and those with graduate course only 0.4 per cent. This indicates that most of the nurses are front nursing technical high schools and three year nursing junior colleges. Accordingly, it is advisable that nursing services be divided according to their functions, such as professional, technical nurses and nurse's aides. 7. The survey also shows that the purpose of nursing service administration in the hospitals has been regulated in writing in 74 per cent of the hospitals and not regulated in writing in 26 per cent of the hospitals. The general purposes of nursing are as follows: patient care, assistance in medical care and education. The main purpose of these nursing services is to establish proper operational and personnel management which focus on in-service education. 8. The nursing service departments belong to the medical departments in almost 60 per cent of the hospitals. Even though the nursing service department is formally separated, about 24 per cent of the hospitals regard it as a functional unit in the medical department. Only 5 per cent of the hospitals keep the department as a separate one. To the contrary, approximately 12 per cent of the hospitals have not established a nursing service department at all but surbodinate it to the other department. In this respect, it is required that a new hospital organization be made to acknowledge the independent function of the nursing department. In 76 per cent of the hospitals they have advisory committees under the nursing department, such as a dormitory self·regulating committee, an in-service education committee and a nursing procedure and policy committee. 9. Personnel arrangement and working conditions of nurses 1) The ratio of nurses to patients is as follows: In university hospitals, 1 to 2.9 for hospitalized patients and 1 to 4.0 for out-patients; in religious hospitals, 1 to 2.3 for hospitalized patients and 1 to 5.4 for out-patients. Grouped together this indicates that one nurse covers 2.2 hospitalized patients and 4.3 out-patients on a daily basis. The current medical treatment law stipulates that one nurse should care for 2.5 hospitalized patients or 30.0 out-patients. Therefore the statistics indicate that nursing services are being peformed with an insufficient number of nurses to cover out-patients. The current law concerns the minimum number of nurses and disregards the required number of nurses for operation rooms, recovery rooms, delivery rooms, new-born baby rooms, central supply rooms and emergency rooms. Accordingly, tile medical treatment law has been requested to be amended. 2) The ratio of doctors to nurses: In university hospitals, the ratio is 1 to 1.1; in national of public hospitals, 1 to 0.8; in religious hospitals 1 to 0.5; and in private hospitals 1 to 0.7. The average ratio is 1 to 0.8; generally the ideal ratio is 3 to 1. Since the number of doctors working in hospitals has been recently increasing, the nursing services have consequently teen overloaded, sacrificing the services to the patients. 3) The ratio of nurses to clerical staff is 1 to 0.4. However, the ideal ratio is 5 to 1, that is, 1 to 0.2. This means that clerical personnel far outnumber the nursing staff. 4) The ratio of nurses to nurse's-aides; The average 2.5 to 1 indicates that most of the nursing service are delegated to nurse's-aides owing to the shortage of registered nurses. This is the main cause of the deterioration in the quality of nursing services. It is a real problem in the guest for better nursing services that certain hospitals employ a disproportionate number of nurse's-aides in order to meet financial requirements. 5) As for the working conditions, most of hospitals employ a three-shift day with 8 hours of duty each. However, certain hospitals still use two shifts a day. 6) As for the working environment, most of the hospitals lack welfare and hygienic facilities. 7) The salary basis is the highest in the private university hospitals, with enterprise hospitals next and religious hospitals and national or public ones lowest. 8) Method of employment is made through paper screening, and further that the appointment of nurses is conditional upon the favorable opinion of the nursing directors. 9) The unemployment ratio for one year in 1971 averaged 29 per cent. The reasons for unemployment indicate that the highest is because of marriage up to 40 per cent, and next is because of overseas employment. This high unemployment ratio further causes the deterioration of efficiency in nursing services and supplementary activities. The hospital authorities concerned should take this matter into a jeep consideration in order to reduce unemployment. 10) The importance of in-service education is well recognized and established. 1% has been noted that on the-job nurses. training has been most active, with nursing directors taking charge of the orientation programs of newly employed nurses. However, it is most necessary that a comprehensive study be made of instructors, contents and methods of education with a separate section for in-service education. 10. Nursing services'activities 1) Division of services and job descriptions are urgently required. 81 per rent of the hospitals keep written regulations of services in accordance with nursing service manuals. 19 per cent of the hospitals do not keep written regulations. Most of hospitals delegate to the nursing directors or certain supervisors the power of stipulating service regulations. In 21 per cent of the total hospitals they have policy committees, standardization committees and advisory committees to proceed with the stipulation of regulations. 2) Approximately 81 per cent of the hospitals have service channels in which directors, supervisors, head nurses and staff nurses perform their appropriate services according to the service plans and make up the service reports. In approximately 19 per cent of the hospitals the staff perform their nursing services without utilizing the above channels. 3) In the performance of nursing services, a ward manual is considered the most important one to be utilized in about 32 percent of hospitals. 25 per cent of hospitals indicate they use a kardex; 17 per cent use ward-rounding, and others take advantage of work sheets or coordination with other departments through conferences. 4) In about 78 per cent of hospitals they have records which indicate the status of personnel, and in 22 per cent they have not. 5) It has been advised that morale among nurses may be increased, ensuring more efficient services, by their being able to exchange opinions and views with each other. 6) The satisfactory performance of nursing services rely on the following factors to the degree indicated: approximately 32 per cent to the systematic nursing activities and services; 27 per cent to the head nurses ability for nursing diagnosis; 22 per cent to an effective supervisory system; 16 per cent to the hospital facilities and proper supply, and 3 per cent to effective in·service education. This means that nurses, supervisors, head nurses and directors play the most important roles in the performance of nursing services. 11. About 87 per cent of the hospitals do not have separate budgets for their nursing departments, and only 13 per cent of the hospitals have separate budgets. It is recommended that the planning and execution of the nursing administration be delegated to the pertinent administrators in order to bring about improved proved performances and activities in nursing services.

  • PDF