• Title/Summary/Keyword: Manikin

Search Result 147, Processing Time 0.02 seconds

Determining thermal comfort properties of coverall worn in the atomic power plant using a sweating thermal manikin and ISO 7730 (발한 Thermal manikin과 국제 표준 7730을 이용한 원자력 발전소 작업복의 열적 쾌적성 판별)

  • 홍성애
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.91-103
    • /
    • 1996
  • For determining thermal comfort properties of work suit in an atomic power plant, three different coverall ensembles (PVE, PET/Rayon, PP Nonwoven) were selected and the resistance to dry and evaporative heat transfer were measured for each ensemble by using a sweating thermal manikin. Also, PMV (Predicted Mean Vote) and PPD(Predicted Percentage of Dissatisfied) indices were predicted according to ISO 7730. As a result, ideal environmental conditions in an atomic power plant were suggested to make workers feel thermally comfortable. In addition, ideal intrinsic insulation values of coverall ensembles as a work suit under the present environmental conditions in the at6omic power plant were provided. The information given in this paper can be used to control environmental conditions in the atomic power plant thermally comfortable and to select a proper work suit for providing thermal comfort to the workers.

  • PDF

Comparative assessment of the easiness and speed of insertion of three supraglottic airway devices - A manikin study - (3가지 성문위기도기(Supraglottic airway device)의 삽관 용이성과 삽관시간 비교 - 마네킨을 이용한 연구-)

  • Kim, Sang-Tae;Kang, Bo-Ra;Tak, Yang-Ju
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.2
    • /
    • pp.23-30
    • /
    • 2012
  • Purpose : This study was designed to compare the easiness and speed of insertion of three supraglottic airway devices(SADs) in a manikin setting. Methods : Three different SADs - Laryngeal Mask Classic(cLMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. One hundred and nineteen paramedical students with(group H) or without (group L) previous airway experience were taught brief manikin training about the use of the cLMA, I-gel and SLIPA. The students inserted each device in a randomized order. Time to effective ventilation was recorded in seconds from holding the device to the first chest inflation. Success was determined as adequate chest wall movement. Results : The insertion attempts were lesser in I-gel($1.00{\pm}0.00$) and SLIPA($1.05{\pm}0.27$) than cLMA($1.16{\pm}0.41$, p<.05). The shortest time to insertion was recorded for I-gel($10.5{\pm}3.0sec$), followed by the SLIPA($12.9{\pm}4.5sec$) and cLMA($19.6{\pm}4.1sec$, p<.05). There were no significant differences in the insertion attempts and insertion time of I-gel between group L and group H. But in cLMA, longer insertion time and more insertion attempts were recorded in group L than group H. Conclusion : Both I-gel and SLIPA were superior to cLMA in the easiness and speed of insertion. Even in novice students, I-gel showed an excellent result in a manikin.

The Evaluation of Thermal Properties of Pesticide Protective Clothing using the Surface Temperature Controlled Thermal Manikin (열 마네킹을 이용한 부직포 농약 방호복의 열적 성능 평가)

  • Choi, Jong-Myoung
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.119-127
    • /
    • 1998
  • The purpose of this study was to evaluate thermal properties of pesticide protective clothing made of three different nonwoven fabrics which have barrier properties of pesticide. In order to assay the thermal properties of experimental clothing, thermal resistance measurements for clo value and thermographic assessment were conducted using a surface temperature controlled thermal manikin. The thermal manikin was dressed with underwear and experimental clothing. Air temperature in a climate chamber was kept at $28^{\circ}C$ and its humidity was 70% RH. Air velocity was controlled at less than 0.15m/s. Inner radient temperature was almost equal to the air temperature. The basic thermal insulation value(Icl) of underwear was 0.28 clo. The thermal properties of the experimental clothing were varied according to the type of material used in construction. The basic clothing insulation value for C1(spunbonded nonwoven fabric), C2(spunlaced nonwoven fabric), C3(SMS nonwoven fabric) were 0.705 clo, 0.725 clo, 0.738 clo respectively. The C3 experimental clothing made of SMS resulted in higher surface temperatures than the others with more yellowing spots being evident on the thermogram.

  • PDF

The Effects of Parka on Subject Wear Sensation as to Thermal Resistance (파카의 보온성에 따른 착용감에 관한 연구)

  • Lee Yoon-Jung;Lee Soon-Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.3 s.31
    • /
    • pp.295-303
    • /
    • 1989
  • This study is to measure the thermal resistance of 7 types of Parka of different materials with thermal manikin and to compare their effects on physiological responses & subjective wear sensations. Following are the results obtained from the experiments 1) From the thermal manikin experiment, i) As an outer layer, although not significant, water proof fabric was warmer than water proof-vapor permeable fabric. ii) In case of insulating material, down was better for thermal resistance than polyester wadding of the same thickness. Moreover, as the down was thicker, it had more efficiency in thermal resistance. However, the marginal efficiency of thickness was found to be decreasing. 2) From the male-subject experiments, i) Chest temperature, mean skin temperature & microclimate temperature showed the same results on thermal resistance as those of the thermal manikin experiment. ii) Only during rest periods, there was a significant difference among 5 insulating materials in the sense of microclimate humidity. The almost same conclusion was obtained from the above experiments. Even the outer layer did not significantly affect thermal resistance & subjective wear sensation, insulating materials had a significant influence upon them. But in case of 3.5 cm down, it gave less comfortable than that of the thinner. Therefore the optional one for the best comfort & thermal resistance among 7 combinatins is the outer layer of water proff-vapor permeable & insulating material of 2.1 cm down.

  • PDF

Development of the Basic Life Support App Including Chest Compression Feedback (흉부압박 피드백 기능이 포함된 기본소생술 앱 개발)

  • Song, Yeongtak;Kim, Minwoo;Kim, Jinsung;Oh, Jaehoon;Chee, Youngjoon
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.219-226
    • /
    • 2014
  • This study is to develop a basic life support (BLS) app using the android based smartphone and to evaluate the function of the app. Suggested app contains chest compression feedback function, the map of automated external defibrillator (AED), direct emergency call and the basic knowledge of BLS. Using the accelerometer of the smartphone, we implemented a real-time algorithm that estimates the chest compression depth and rate for high quality cardiopulmonary resuscitation (CPR). The accuracy of algorithm was evaluated by manikin experiment. We made contents which were easy to learn the BLS for the layperson and implemented a function that provides the AED location information based on the user's current location. From the manikin experiment, the chest compression depth and rate were no significant differences between the manikin data and the app's feedback data (p > 0.05). Developed BLS app was uploaded on Google Play Store and it was free to download. We expected that this app is useful to learn the BLS for the layperson.

Effects of Injection Practice Education Methods on Anxiety in Nursing Students (주사실습 교육방법이 간호학생의 불안에 미치는 영향)

  • Choi, Sungyeau
    • Korean Parent-Child Health Journal
    • /
    • v.19 no.1
    • /
    • pp.17-24
    • /
    • 2016
  • Purpose: This study examined the level of students' anxiety depending on the injection type, education methods, and the students' characteristics. Methods: 209 first year nursing students were randomly assigned to each group by three factors -injection methods, video watching, and number of practice. Injection methods had two levels (IV and IM). Video watching also had also two levels (video watching and non-watching group). And the number of practice had 4 levels according to number of practice (2, 4, 6, and 8 times). The video watching group was watching 30 minutes video before manikin practice. After 5 to 15 minutes of manikin practice, the sufficiency of practice and the level of anxiety were measured. The data were analyzed by t-test and one way ANOVA. Results: The anxiety of the IV practice was higher than that of IM. The students who have experiences of working at hospital or the similar institution were lower in anxiety. The higher self-confident in sufficiency of practice lowered the students' anxiety. But watching video and the number of practices had no effects on the level of anxiety. Conclusion: To effectively lower the anxiety of nursing students in the nursing practice education, lecture methods and education tools are needed to develop.

  • PDF

Thermal Comfort and Tactile Wearing Performance of Wool/nylon Fabrics for Tra-biz Garment (울/나일론 tra-biz 의류용 직물 소재의 열적 쾌적성과 착용특성)

  • Kim, Hyun Ah
    • Fashion & Textile Research Journal
    • /
    • v.18 no.6
    • /
    • pp.878-888
    • /
    • 2016
  • In this study, wool/nylon(50/50%) blend yarn and its fabrics for tra-biz(complex word of travel+business) garment were prepared, and its wear comfort characteristics were investigated through thermal manikin and human-body wearing experiment. In addition, tactile wearing performance from fabric mechanical properties and the dimensional stability and the pilling of the fabric specimen during wearing and dry-cleaning were measured and compared with those of wool 100% fabric specimen. Heat keepability of the wool/nylon(50/50%) blend fabric by thermal manikin experiment was superior than that of wool 100% fabric, this result was verified with human-body wearing experiment and its result coincided well with this experimental result. Tactile wearing performance of the wool/nylon(50/50%) fabric from fabric mechanical properties measured by FAST system was better than that of the wool 100% fabric. The dimensional stability of the wool/nylon(50/50%) fabric was more stable than that of the wool 100% fabric. Because relaxation shrinkage was lower and hygral expansion of wool 100% fabric was more high. However, the breathability and pilling property of the wool/nylon(50/50%) fabric were inferior than those of the wool 100% fabric. The possibility of application for tra-biz garment of wool/nylon(50/50%) blend fabric was observed because of good heat keepability, tactile wearing performance and washing fastness.

Filtration efficiency and Manikin-based Total Inward Leakage Study of Particle Filtering Mask Challenged with Silver Nanoparticles (은나노입자에 대한 방진마스크 포집효율 및 총누설율)

  • Kim, Jong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.367-376
    • /
    • 2016
  • Objectives: The production and use of nanoparticles have been increased. In 2014 Workplace Survey Results, 335 companies produce and treat nanoparticls. However, lack of data on nano-toxicity and a method for risk management and regulation on nanoparticles and the standard test method are not sufficient. Protective equipment selection guidelines for nanoparticles are not established. It is required to carry out respirator efficiency test against nanoparticles. This study was performed to evaluate filtration efficiency and manikin-based total inward leakage of particle filtering mask using in Korean country challenged with silver nanoparticles. Methods: We investigated filtration efficiency and total inward leakage of 7 respirator with silver nanoparticle. Results: The geometric mean diameters of Silver nanoparticles were 30 nm and number concentration were about $10^6{\sharp}/cm^3$. Filtration efficiency of six of the seven particle filtering masks was more than 98% and one particle filtering masks filtration efficiency was 94.9%. The filtration efficiency of particle filtering masks to 20 nm silver nanoparticels was highest. Artificial breathing machine with manikin based total inward leakage were 7.6% ~ 42.3%. Conclusions: The results of this study nano-silver filter efficiency was high but the total inward leakage was higher than filter penetration. Therefore, education on how to wear a respirator should be demanded. Especially for workers handling nanoparticles and toxic material, user seal checking and fit test must be performed.

Comparison between laryngeal tube suction II and laryngeal mask airway in novice users - A manikin study - (초보자에서 후두튜브기도기와 후두마스크기도기의 삽관 비교 - 마네킨 연구 -)

  • Hwang, Ji-Young;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.3
    • /
    • pp.19-28
    • /
    • 2012
  • Purpose : The present study was designed to provide basic data for advanced pre-hospital airway management by comparing the insertion time and success rate between laryngeal tube suction II (LTS II) and laryngeal mask airway (LMA) in a manikin. Methods : A total of 32 participants were novice users to both of devices among paramedic students. After taking the introductory lecture and demonstrations, the participants made an attempt to insert the LTS II and LMA to compare the insertion time and success rate. They marked the easiness of insertion of the score ranged from 1 to 10 score scale and preference of the two devices. Results : The insertion time of the LTS II was significantly shorter than that of the LMA (p =.000). There was no significant difference between LTS II and LMA in the success rate. In the easiness of insertion, the score of LTS II $(8.47{\pm}1.41score)$ was significantly higher than that of LMA $(7.19{\pm}1.98score)$(p =.001). The preference of LTS II (75%) was much higher than that of LMA (25%). Conclusion : The manikin study data showed that the LTS II may be a good alternative airway device for providing and maintaining a patent airway.

Effects of gum elastic bougie in intubation with difficult airway (마네킹을 이용한 어려운 기도에서 부지 기관 내 삽관의 효과)

  • Shim, Gyu-Sik;Bang, Sung-Hwan;Ahn, Hee-Jeong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.2
    • /
    • pp.123-131
    • /
    • 2020
  • Purpose: This study aimed to find out the effectiveness of gum elastic bougies for intubation in comparison to stylet according to airway type using a manikin. Methods: The study subjects were 52 paramedic students who intubated using a Macintosh laryngoscope and compared stylet and gum elastic bougie use in a 7.5 mmID endotracheal tube, on a manikin with either normal or difficult airway. Difficult airway was made Philadelphia neck collar. Collected data included intubation time, accuracy and ease of intubation, later analyzed by frequency analysis, descriptive analysis, independent t-test, chi square test, paired t-test, and McNemar test using SPSS Statistics 18.0. Results: There was a significant difference in intubation time according to intubation device and airway type (p=.000). There was no significant difference in accuracy of intubation according to intubation device or airway type (normal airway p=1.000, difficult airway p=.052). There was a significant difference in ease of intubation scale according to intubation device and airway type (p=.000, p=.000). Conclusion: Based on the speed and ease of intubation, gum elastic bougie is recommended for intubation in patients with difficult airways such as those with cervical injury.