• Title/Summary/Keyword: Mandible fractures

Search Result 132, Processing Time 0.024 seconds

RESORBABLE PLATES FOR THE FIXATION OF MANDIBULAR FRACTURES: CASE REPORTS AND REVIEW OF THE LITERATURE (하악골 골절 치료시 생체 흡수성 고정판 사용: 증례 보고 및 문헌고찰)

  • You, Jae-Seek;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.2
    • /
    • pp.182-190
    • /
    • 2008
  • Fracture of mandible is the most frequent fracture among many types of maxillofacial fracture, and reduction of mandible fracture is performed using various methods of treatment to maintain bonding strength of fractured bone. Among these treatment of bone fracture, a semirigid fixation method which can reduce the period of intermaxillary fixation using metal mini plate under general or local anesthesia is spotlighted these days. The metal mini plate used during this semirigid fixation procedure is Titanium which is bio-inactive one and was used widely, but because the side effect of fracture reduction using titanium have been demonstrated recently, fracture reduction using biodegradable plate become to attract people's attention. The purpose of this study was to report the clinical case and review of the literature with the reduction of mandible fracture using biodegradable plate.

THE SHORT-TERM REMOVABLE INTERMAXILLARY FIXATION CARE BY USE OF AN ADDITIVE INCISION & DRAINAGE ON THE ORAL LACERATION WOUNDS ADJACENT WITH MANDIBULAR COMPOUND FRACTURES: REPORT OF A CASE (하악골 복합 골절시 구내 열창부 상에 추가 절개 배농술을 이용한 단기간 가변적 악간고정 관리: 증례보고)

  • Mo, Dong-Yub;Yoo, Jae-Ha;Choi, Byung-Ho;Kim, Ha-Rang;Lee, Chun-Ui;Ryu, Mi-Heon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.260-264
    • /
    • 2010
  • Treatment of the mandibular fracture consists of reduction and fixation. The apparatus that is used to keep the jaws together during healing will often reduce the fracture as well. When the jaws are brought together and intermaxillary elastic rubber traction is placed, the occlusion of the teeth will help to orient the fractured parts into good position. Intermaxillary fixation, that is, fixation obtained by elastic bands between the upper & lower jaws to which suitable anchoring devices have been attached, will successfully treat most fractures of the mandible. Arch bars are perhaps the ideal method for intermaxillary fixation. Several types of ready-made arch bars are used. But, daily occupational life and oral hygiene is difficult to maintain during the period of longterm immobilized intermaxillary fixation (commonly 6-8 weeks), owing to malnutrition and emotional disorders in a position of the patient with mandibular fractures. Most mandibular fractures heal well enough to allow removal of fixation in about 6 weeks. Though there are many complications of mandibular fracture, such as infection, hemorrhage, trismus, paresthesia and nonunion, it is favorable to attain the short-term removable intermaxillary fixation care by use of an additive incision & drainage establishment on the oral lacerated wounds of adjacent mandibular compound fractures. The purpose of an additive incision & drainge establishment is the prevention of wound infection & nonunion by removing the hematoma & seroma in the fracture sites.

Reduction of superior-lateral intact mandibular condyle dislocation with bone traction hook

  • Kim, Bong Chul;Samayoa, Sara Rebeca Kang;Kim, Hyung Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.5
    • /
    • pp.238-241
    • /
    • 2013
  • Lateral and superior-lateral dislocations of the intact condyle are a rare complication, following traumatic insult to the mandible. We report an unusual case of a 54-year-old male patient who experienced both types of dislocations of the intact condyles with symphysis fracture following a road-traffic accident. Under general anesthesia, conventional manipulation was unsuccessful in relocating the condyles into the glenoid fossa. After applying a percutaneous traction force, using a bone traction hook placed at the sigmoid notch, the displaced intact mandibular condyles were repositioned, and the symphyseal fracture was finally reduced and fixed. The mouth opening was within normal limits, and favorable occlusion was confirmed one month postoperatively. To our knowledge, this is the first case of dislocation of both intact condyles--associated with symphysis fracture--being reduced with bone traction hook.

Use of a Y-Shaped Plate for Intermaxillary Fixation

  • Kim, Tae Hoon;Yang, Il Hyung;Minn, Kyung Won;Jin, Ung Sik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.2
    • /
    • pp.96-98
    • /
    • 2015
  • Maxillomandibular fractures usually require intermaxillary fixation as a means to immobilize and stabilize the fracture and to re-establish proper occlusion. Arch bars or intermaxillary fixation screws cannot be used for edentulous patients or for patients who have poor dental health. Here, we present a case of repeated intermaxillary fixation failure in a patient weak alveolar rigidity secondary to multiple dental implants. Because single-point fixation screws were not strong enough to maintain proper occlusion, we have used Y-shaped plates to provide more rigid anchoring points for the intermaxillary wires. We suggest that this method should be considered for patients in whom conventional fixation methods are inappropriate or have failed.

A case of bisphosphonate-related osteonecrosis of the jaw with a particularly unfavourable course: a case report

  • Viviano, Massimo;Addamo, Alessandra;Cocca, Serena
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.4
    • /
    • pp.272-275
    • /
    • 2017
  • Bisphosphonates are drugs used to treat osteoclast-mediated bone resorption, including osteoporosis, Paget disease, multiple myeloma, cancer-related osteolysis, and malignant hypercalcemia. The use of these drugs has increased in recent years as have their complications, especially bisphosphonate-related osteonecrosis of the jaw (BRONJ), which more frequently affects the mandible. Here we report a case of BRONJ with a particularly unfavorable course due to cervical inflammation that developed into necrotizing fasciitis, followed by multiorgan involvement leading to septic shock and death.

A Case of External Skeletal Fixation for Treatment of Bilateral Mandibular Fracture in a Dog (개에서 외부고정법을 이용한 양측성 하악골절의 치유 일례)

  • 구자민;김현희;박대식;장홍희;이효종;이후장;송해룡;이용훈;정종태
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.134-137
    • /
    • 2003
  • A 5-year-old, male mixed breed dog was presented to Gyeongsang National University Animal Hospital for bilateral mandibular open fracture by bite. The dog had loss of the teeth and injury of the oral mucosa. Radio-graphic and blood examinations were conducted. Fracture lines were observed between first premolar and second premolar, but temporomandibular luxation was not observed on radiographs. In serum analysis, elevated levels of CPK and LDH were found. The dog was anesthetized and prepared for aseptic surgery. Acrylic external skeletal fixator with Kirschiner wire was applied. Pin loosening and malalignment of the right fracture line was observed at 7 weeks after surgery. We applied Kirschner-Ehmer fixator and half pins during the second surgical procedure. At 4 weeks after a second surgical procedure, the fixator and pins were removed from mandible. The fractures were healed with no complications.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.

Usefulness of Atelo-collgen sponge (Teruplug$^{(R)}$) for Treatment of Mandibular Angle Fractures with Third Molar Extraction (하악각 골절에서 제 3 대구치 발치 후 아테로-콜라겐 스펀지의 유용성)

  • Oh, Hwa-Young;Choi, Hwan-Jun;Kwon, Jun-Seong;Lee, Hyung-Gyo;Kim, Yong-Bae
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.155-160
    • /
    • 2011
  • Purpose: Fibrillar collagens like type I collagen, are the major constituent of the extracellular matrix and structural protein of bone. Also, it can be a scaffold for osteoblast migration. The purpose of this study is to estimate the effects of absorbable atelo-collagen sponge (Teruplug$^{(R)}$, Terumo biomaterials Co., Tokyo, Japan) insertion in tooth extraction sites on periodontal healing of the second molar, healing of the fractured mandibular bone and new bone formation of third molar socket after the extraction of the impacted third molar with mandibular angle fracture. Methods: In our study of six cases of mandibular angle fractures, all of them underwent the extraction of the third molar tooth & absorbable atelo-collagen sponge insertion in tooth extraction site. Three of them had a intraoral infection & oral opening to fracture site, two of the six had dental caries, and only one had reduction problem due to third molar position. Six consecutive patients with noncomminuted fractures of the mandibular angle were treated by open reduction and internal fixation using one noncompression miniplates and screws placed through a transoral incision. Results: All of the patients have showed good postoperative functions and have not experienced complications requiring second surgical intervention. There was well healing of the mandibular bone and the most new bone formation of third molar socket after the extraction of the impacted third molar with mandibular angle fracture. Conclusion: The results of this study suggest that absorbable atelo-collagen sponge is relatively favorable bone void filler with prevention of tissue collapse, food packing, and enhance periodontal healing. Thus, the use of atelo-collagen sponge and one noncompression miniplate seems to be relatively easy, safe, and effective for the treatment of fractures of the mandibular angle and third molar extraction.

Hyoid Bone Fracture Associated with Hypoglossal Nerve Palsy: A Case Report (설하신경마비를 동반한 설골골절: 증례보고)

  • Kim, Sin-Rak;Park, Jin-Hyung;Han, Yea-Sik
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.199-202
    • /
    • 2011
  • Purpose: Hyoid bone is a U-shaped bone in the anterior of the neck. Hyoid bone fractures are exceedingly rare and represent only 0.002% of all fractures because of its protective position relative to the mandible and its suspension by elastic musculature. We report a patient who presented hyoid bone fracture associated with hypoglossal nerve palsy. We also discuss the possible complication and treatment. Methods: A 69-year-old man was transferred from another institution because of persistent purulent discharge from the left chin. He had a history of trauma in which a knuckle crane grabbed his face and neck in the construction site. A CT scan at the time of the accident demonstrated a comminuted fracture of the right side of the mandible and hyoid bone fracture at the junction between body and right greater cornua. The displaced fracture of hyoid bone and fullness in the pre-epiglottic space were noted, probably indicating some edema. The patient was transferred into ICU after treatment of emergency tracheostomy because the patient showed respiratory distress rapidly. When the patient was hospitalized in our emergency room, he complained of dysphagia and pain when swallowing. On examination of oral cavity, the presence of muscle wasting with fasciculation of the tongue was noted and the tongue deviates to the left side on protruding from the mouth. Pharyngolarygoscopy was performed to make sure that there was no evidence of progressive swelling and pharyngeal laceration. Results: The patient underwent surgical removal of dead and infected tissue from the wound and reconstruction of mandibular bony defect by iliac bone grafting. Hyoid bone fracture was managed conservatively with oral analgesics, soft diet and restricted movement. Hypoglossal nerve palsy was resolved within 7 weeks after trauma without complications. Conclusion: Closed hyoid bone fracture is usually uncomplicated and thus it can be treated conservatively. Surgical intervention for hyoid bone fracture is recommended for patient with airway compromise, pharyngeal perforation and painful symptoms which show no response to conservative care. Furthermore, since respiratory distress syndrome may develop quickly, close observation is required. Besides, hypoglossal nerve palsy is a rarely recognized complication of hyoid bone fracture.

흉총창에 의한 심방파열 치험 2례

  • Lee, Doo-Yun;Kwack, Sang-Ryong
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.60-65
    • /
    • 1980
  • We have experienced 2 cases of the hunshot wound sof the chest involving cardiac injuries at department of the thoracic surgery, Capital Armed Forces General Hospital during I year from April I 1979 to Jan. 1980. In one case of two patients , he was a 22 years old man who was transported to this emergency room 4 hour 10 minutes after having gunshot wound of the left chest by helicopter. Physical examination showed small inlet in left 3rd ICS and left parasternal border, large outlet in left 8th ICS and left scapular line, no breath sound on left side and distant heart sound. chest roentgenography demonstrated marked pleural effusion in left side and mediastinum shifted to right. As soon as chest X-ray was taken, the bleeding through penetrating wound became profuse and cardiac arrest ensued. Closed chest cardiac massage was started and vigorous transfusion continued, but no effective cardiac activity could not be obtained. The patient was pronounced dead due to exsanguinating hemorrhage from wuwpected cardiac wounds. In this critically injured patient with evidence of intrathoracic hemorrhage and suspected cardiac penetration, only emergency thoracic exploration and immediate surgical control of bleeding points might offer the maximum possibility of survival. The other case was a 23 years old man who was transferred to the emergency room 4 hours 50 minutes after having kmultiple communicated fractures of sternum and linear fracture of right mandible by a missile. Examination revealed about 30% skin loss of the anterior chest wall, weak pulse of 96 beats/min., distant heart sound and decreased breath sounds bilaterally. finding on the chest X-ray films showed multiple sternal fractures, marked pericardial effusion indicating hemopericardium. So, the patient was moved immediately to the operation room where, after endotracheal tube inserted, a median sternotomy was performced. A hemorrhagic congestion of the right upper lobe and marked bulging pericardium were disclosed. The pericardium was opened anterior to right phrenic nerve and exsanguinating hemorrhage ensued from the 0.5cm lacerated wound in the auricle of right atrium. The rupture site of right atrium was occluded with non-crushing vascular clamps and then was over sewn with interrupted sutures. It was thought to be highly possible that he was alive long enough to have cardiorrhaphy because of cardiac tamponade, which prevented exsanguinating hemorrhage. He was taken closed reduction for linear fracture of right mandible 2 weeks after repair of ruptured right auricle in dental clinic. This patient's post-operative course was not eventful.

  • PDF