• Title/Summary/Keyword: Manchester coding

Search Result 21, Processing Time 0.035 seconds

Effects of Upstream Bit Rate on a Wavelength-Remodulated WDM-PON Based on Manchester or Inverse-Return-to-Zero Coding

  • Chung, Hwan-Seok;Kim, Bong-Kyu;Kim, Kwang-Joon
    • ETRI Journal
    • /
    • v.30 no.2
    • /
    • pp.255-260
    • /
    • 2008
  • We compare the performance of a wavelength remodulated wavelength-division-multiplexed passive optical network implemented using Manchester-coded or inverse-return-to-zero (IRZ)-coded signal downstream and non-return-to-zero remodulated signal upstream. We investigate the effects of varying differences between downstream and upstream bit rates on the two coding schemes. When the bit rate ratio of upstream to downstream is less than or equal to 50%, the performance of Manchester coding is better than that of IRZ coding. However, when the bit rate ratio of upstream to downstream is higher than 50%, Manchester code requires appropriate time delay between upstream and downstream signals, whereas IRZ code needs reduced extinction ratio in the downstream signal.

  • PDF

Experimental Study on Flicker Mitigation in VLC using Pseudo Manchester Coding (VLC에서 Pseudo Manchester Coding을 사용한 Flicker 최소화에 관한 실험 연구)

  • Ifthekhar, Md. Shareef;Le, Nam-Tuan;Jang, Yeong Min
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.3
    • /
    • pp.116-120
    • /
    • 2014
  • Visible Light Communication is one of the promising technologies for wireless communication due to the possibility to use existing LED lightening infrastructure to transmit data. LED has the ability to turn on and off very fast enough that our human eyes can't recognize so it can be used to transmit data via visible light along with illumination. But it faces flicker problem due to the brightness discrepancies between '1' and '0' bit patterns inside a data frame. Various run length limited (RLL) coding scheme like Manchester code, 4B6B, 8B10B or VPPM can be used to solve flickering problem. So we propose pseudo Manchester codding which can transmit data without modifying LED modulator and demodulator circuit as well as solve flickering problem.

Design and Implementation of the Manchester Encoder for RFID (RFID용 Manchester Encoder의 설계 및 구현)

  • Kim Ki-Ho;Kim Jae-Hyung;Park Hyung-Moo
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.525-528
    • /
    • 2004
  • Manchester encoder of FSM method is a suitable signal coding for an RFID system. However, Manchester encoder of FSM method has usually more gate count and lower maximum frequency than encoder of exclusive-OR gate method. In this paper. it is proposed encoder of FSM method to improve gate count and maximum frequency.

  • PDF

Performance Improvement of 16-QAM for Employing Miller Coding Technique in Rayleigh Fading Environment (레일레이 페이딩 환경하에서 밀러부호화 기법에 의한 16-QAM 통신방식의 성능개선)

  • 김태헌;하덕호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.3
    • /
    • pp.289-295
    • /
    • 1998
  • The purpose of this paper is to propose an improvement method of BER for coded 16-QAM under Rayleigh fading channel. To overcome the BER degradation due to the fading under mobile communication, we apply delay modulation technique which is efficient to get both a coding gain and approximately one-half those needed by Manchester coding on bandwidth requirements. Especially, the delay modulation scheme is insensitive to the $180^{\circ}$phase ambiquity common to NRZ-L and Manchester coding schemes. From the computer simulation, BER performance of our scheme has achieved about 3.8 dB improvement of about $10^{-4}$, compared to Manchester coded 16-QAM.

  • PDF

REMARK OF Pi,k ON ELLIPTIC CURVES AND APPLICATION FOR MANCHESTER CODING

  • Kim, Dae-Yeoul;Kim, Min-Soo
    • Honam Mathematical Journal
    • /
    • v.33 no.2
    • /
    • pp.153-161
    • /
    • 2011
  • Greg([Greg]) considered that $$N_k= \sum\limits_{i=1}^k(-1)^{i+1}P_{i,k}(p)N_1^i$$ where the $P_{i,k}$'s were polynomials with positive integer coefficients. In this paper, we will give the equations for $\sum\limits{P_{i,k}$ modulo 3. Using this, if we send a information for elliptic curve to sender, we can make a new checksum method for Manchester coding in IEEE 802.3 or IEEE 802.4.

Group Manchester Code Scheme for Medical In-body WBAN Systems (의료용 in-body WBAN 시스템을 위한 Group Manchester code 변조 방식)

  • Choi, Il-Muk;Won, Kyung-Hoon;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.10C
    • /
    • pp.597-604
    • /
    • 2011
  • In this paper, we propose group Manchester code (GM) modulation scheme for medical in-body wireless body area network (WBAN) systems. In IEEE, the WBAN system is assigned as 802.15. Task Group 6 (TG 6), and the related standardization is being progressed, Recently, in this Group, group pulse position modulation (GPPM), which can obtain data rate increase by grouping pulse position modulation (PPM) symbols, is proposed as a new modulation scheme for low-power operation of WBAN system. However, the conventional method suffers from BER performance degradation due to the absence of gray coding and its demodulation characteristics. Therefore, in this paper, we propose a modified GM scheme which groups Manchester code instead of PPM. In the proposed GM scheme, a low-complexity maximum likelihood (ML) demodulation method is employed in order to maximize the BER performances, Also, log likelihood ratio (LLR) decision method is proposed to employ the Turbo code as forward error correction (FEC), Finally, we verified that the proposed method has a good performance and is an appropriate scheme for in-body WBAN system through extensive performance evaluation.

Optical Communication Method Using CCR and Manchester Coding (CCR 반사경과 Manchester Coding을 이용한 광(光)통신 기법)

  • Moon, Gong-Bo;Park, Chan-Gook;Lee, Jang-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1792_1793
    • /
    • 2009
  • 최근 활발한 연구가 진행되고 있는 센서 네트워크 시스템은 센서 노드 주변에서 수집된 환경 정보를 베이스로 전달하여 정보를 통합하는 시스템이다. 다양한 환경에 적용하기 위하여 정보 전달에 주로 무선 채널을 활용하는데 기존과 같이 라디오 주파수 채널을 이용하는 경우 센서 노드가 복잡해지고, 도청의 위험성이 존재한다. 본 논문에서는 이러한 단점을 피하기 위해 광(光)채널을 형성하고, 이를 이용하여 데이터를 전송하는 기법을 제안한다.

  • PDF

Manchester coding of compressed binary clusters for reducing IoT healthcare device's digital data transfer time (IoT기반 헬스케어 의료기기의 디지털 데이터 전송시간 감소를 위한 압축 바이너리 클러스터의 맨체스터 코딩 전송)

  • Kim, Jung-Hoon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.6
    • /
    • pp.460-469
    • /
    • 2015
  • This study's aim is for reducing big data transfer time of IoT healthcare devices by modulating digital bits into Manchester code including zero-voltage idle as information for secondary compressed binary cluster's compartment after two step compression of compressing binary data into primary and secondary binary compressed clusters for each binary clusters having compression benefit of 1 bit or 2 bits. Also this study proposed that as department information of compressed binary clusters, inserting idle signal into Manchester code will have benefit of reducing transfer time in case of compressing binary cluster into secondary compressed binary cluster by 2 bits, because in spite of cost of 1 clock idle, another 1 bit benefit can play a role of reducing 1 clock transfer time. Idle signal is also never consecutive because the signal is for compartment information between two adjacent secondary compressed binary cluster. Voltage transition on basic rule of Manchester code is remaining while inserting idle signal, so DC balance can be guaranteed. This study's simulation result said that even compressed binary data by another compression algorithms could be transferred faster by as much as about 12.6 percents if using this method.

Inference of Aspergillus fumigatus Pathways by Computational Genome Analysis: Tricarboxylic Acid Cycle (TCA) and Glyoxylate Shunt

  • Do, Jin-Hwan;Anderson, Michael-J.;Denning, David-W.;Erich, Bornberg-Bauer
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.1
    • /
    • pp.74-80
    • /
    • 2004
  • Aspergillus fumigatus is one of the most common fungi in the human environment, both in-doors and out-doors. It is the main causative agent of invasive aspergillosis, a life-threatening mycosis among immunocompromised patients. The genome has been sequenced by an international consortium, including the Wellcome Trust Sanger Institute (U.K.) and The Institute for Genomic Research (TIGR, U.S.A.), and a ten times whole genome shotgun sequence assembly has been made publicly available. In this study, we identified tricarboxylic acid (TCA) cycle enzymes of A. fumigatus by comparative analysis with four other fungal species. The open reading frames showed high amino acid sequence similarity with the other fungal citric acid enzymes and well-conserved functional domains. All genes present in Saccharomyces cerevisiae, Schizosaccharomyces pombe, Candida albicans, and Neurospora crassa were also found in A. fumigatus. In addition, we identified four A. fumigatus genes coding for enzymes in the glyoxylate shunt, which may be required for fungal virulence. The architecture of multi-gene encoded enzymes, such as isocitrate dehydrogenase, 2-ketoglutarate, succinyl-CoA synthetase, and succinate dehydrogenase was well conserved in A. fumigatus. Furthermore, our results show that genes of A. fumigatus can be detected reliably using GlimmerM.

Lower layer implementation of a fieldbus network interface (Fieldbus 네트워크 접속기의 하위계층 구현)

  • 김현기;이전우;황선호;이혁희;채영도
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.337-341
    • /
    • 1991
  • Fieldbus is a low level serial digital network which will be used for factory automation. This paper describes lower layer implementation of a Fieldbus network interface. Physical layer provides hardware interface between IBM-PC and Fieldbus. Also, physical layer uses manchester coding, shielded twisted pair lines and RS-485 electrical standard. Data link layer includes Intel's iDCX96 real time executive for 8797 one chip microcontroller and Fieldbus data link protocol software.

  • PDF