• 제목/요약/키워드: Man Machine interface

검색결과 231건 처리시간 0.026초

인간-기계 통신 인터페이스를 위한 안구운동 패턴 부호화 방식 (Eye-Movement Pattern Encoding Method for Man-Machine Communication Interface)

  • 이용천;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.153-157
    • /
    • 1989
  • In this paper, a new method of Eye Movement Pattern Encoding (EMPE) which is based on electrooculography(EOG) was suggested for the purpose of effective communication between man and machine, instead of Point-Of-Regard-Selection (PORS) method. Also, ocular interface is designed and the typing aid, eye-pattern writer, was constructed for the test of theoretical validity and its practical aspect. Effect of eye fatigue on the performance of ocular interface was quantified through fatigue test.

  • PDF

Data Management and Communication Networks for Man-Machine Interface System in Korea Advanced Liquid MEtal Reactor : Its Functionality and Design Requirements

  • Cha, Kyung-Ho;Park, Gun-Ok;Suh, Sang-Moon;Kim, Jang-Yeol;Kwon, Kee-Choon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.291-296
    • /
    • 1998
  • The DAta management and Communication NETworks (DACONET), Which it is designed as a subsystem for Man-Machine Interface System of Korea Advanced LIquid MEtal Reactor(KALIMER MMIS) and advanced design concept is approached, is described. The DACONET has its roles of providing the real-time data transmission and communication paths between MMIS systems, providing the quality data for protection, monitoring and control of KALIMER and logging the static and dynamic behavioral data during KALIMER operation. The DACONET is characterised as the distributed real-time system architecture with high performance, Future direction, in which advanced technology is being continually applied to Man-Machine interface System Development of Nuclear Power Plants, will be considered for designing data management and communication networks of KALIMER MMIS

  • PDF

Recent instrumentation system safety instrumentation and man-machine interface

  • Satake, Noboru
    • 전기의세계
    • /
    • 제25권6호
    • /
    • pp.8-13
    • /
    • 1976
  • The industrial processes have become complicated on a large scale bacause of improvement of productivity, research of efficiency, and shortage of locations to be suited for foundation of factories. Consequently, the instrumentation and control systems for operating these industrial processes have also been highly improved with the development of mass information means. In order to operate these large-sized and complicated industrial processes safely, the man-machine interface for correspondence between man and machines and the instrumentation system regarding process fault processing are playing an important role increasingly. This paper describes recent instrumentation system in the water purifying plant as an example of these industrial processes, and covers both man-machine interface and process fault processing. The annual water supply quantity and diffusion were 2, 000, 000, 000m$^{3}$ and 25.0% in 1950 inJapan, but they amounted to 12, 000, 000, 000m$^{3}$ and 86.7% in 1974, respectively. The demands of water will increase incessantly, while it becomes gradually difficult to secure water sources. Accordingly, local self-governing bodies such as municipal cooperation, towns, and villages often construct a large-scale water purifying plant at one place in common, as required, without constructing respective plants independently. It is an absolute requirement for the water purifying plant to avoid stopping water supply to fullfil its social responsibility from the viewpoints of its public utility enterprise, and also it has gradually become difficult to secure skilled operators enough to cover such water purifying plants that are additionally provided in various districts. Thus, the importance of the man-machine interface for assuring safety operation of the water purifying plant irrespective of unskillfulness of operators as well as the instrumentation system regarding process fault processing, or, safety instrumentation, is more and more increasing as the water purifying plants are on a large scale.

  • PDF

화력발전소용 정지형 여자 시스템 MMI(Man-Machine Interface)에 관한 연구 (A Study of Static Excitation System MMI for Thermal Power Plant)

  • 신만수;류호선;이주현;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1012-1014
    • /
    • 2002
  • This paper shows that a static redundancy excitation system for thermal power plant. The detailed contents are system explanation and MMI(Man-Machine Interface) integration, operation mimic graph.

  • PDF

국내(國內) 원전제어실(原電制御室)의 인간공학적설계(人間工學的設計)에 관한 연구(硏究) (A Study on the Design Based on Human Factors in a Korean Nuclear Power Plant Control Rooms)

  • 신현국;오인양;박근옥;김경표
    • 품질경영학회지
    • /
    • 제17권2호
    • /
    • pp.36-46
    • /
    • 1989
  • The problems and current status of man-machine interface design through questionnaire survey and direct check of main control rooms are analyzed and methods for improvement man-machine interface are suggested. Particularly, a design of Korean operator console based on human factors is suggested in this paper.

  • PDF

원자력 발전소 주제어실 인터페이스 설계를 위한 인적오류 분석 기법의 보완 (A Modification of Human Error Analysis Technique for Designing Man-Machine Interface in Nuclear Power Plants)

  • 이용희;장통일;임현교
    • 대한인간공학회지
    • /
    • 제22권1호
    • /
    • pp.31-42
    • /
    • 2003
  • This study describes a modification of the technique for human error analysis in nuclear power plants (NPPs) which adopts advanced Man-Machine Interface (MMI) features based on computerized working environment, such as LCOs. Flat Panels. Large Wall Board, and computerized procedures. Firstly, the state of the art on human error analysis methods and efforts were briefly reviewed. Human error analysis method applied to NPP design has been THERP and ASEP mainly utilizing Swain's HRA handbook, which has not been facilitated enough to put the varied characteristics of MMI into HRA process. The basic concepts on human errors and the system safety approach were revisited, and adopted the process of FMEA with the new definition of Error Segment (ESJ. A modified human error analysis process was suggested. Then, the suggested method was applied to the failure of manual pump actuation through LCD touch screen in loss of feed water event in order to verify the applicability of the proposed method in practices. The example showed that the method become more facilitated to consider the concerns of the introduction of advanced MMI devices, and to integrate human error analysis process not only into HRA/PRA but also into the MMI and interface design. Finally, the possible extensions and further efforts required to obtain the applicability of the suggested method were discussed.

Non-Contact Line-of-sight Detection using Color Contact Lens for Man-Machine Interface

  • Nishiuchi, Nobuyuki;Kurihara, Kenzo;Takada, Hajime
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.391-394
    • /
    • 1998
  • The man-machine interface Is an important factor in the computer system, and it is thought that line-of-sight (LOS) detection technology will allow significant advances in this field. Techniques for detecting LOS for use in human interfaces have been studied[1][2]. In earlier studies, however, LOS was detected with a head piece, goggles, or through fixing the position of the head. The limitations imposed by these fixed conditions render them unsuitable far use in interfaces, as they have adverse mental or physical effects on humans. Therefore. they have not been sufficiently developed for practical application. Research on non-contact LOS detection is expected to result in a usable LOS man-machine interface[3][4], and the current study is intended to be a step in that direction. The authors used color contact lenses for LOS detection, and applied this new method to a computer interface. The use of color contact lenses simplifies image processing. The algorithm used in this study is sufficiently accurate for practical applications. This technique can be used in input devices, in virtual reality applications, and in human engineering research.

  • PDF

포항제철소 B/C-P/C 통합을 위한 개방형 MMI 개발 (Development of open MMI system for integration of business computers and process computers)

  • 추영열;김경백;황화원;김영일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.684-687
    • /
    • 1997
  • In order to access to the Business Computer (B/C), the Process Computer(P/C), and the Database Server in one terminal, the Open Man Machine Interface (MMI) System has been developed. The testbed to develop the interface functions for B/C, P/C, DB server, and CCD camera were constructed, which consisted of Workstations and Personal Computers (PC). Graphic display programs Monitoring the process states of Tandem Cold Mill plant were developed using four Graphic User Interface tools: InTouch, FIX32, Open Interface Environment, and ILOG Views. With regard to the CPU utilization and response delay required to open new display, the performance tests have been carried out on each MMI platform.

  • PDF

트랙터 3점 히치의 인간-기계 인터페이스 동작에 관한 연구 (A Study on Operation of Man-Machine Interface for Tractor 3-point Hitch)

  • 이상식;이충호;이제용;문정환
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.284-291
    • /
    • 2007
  • This study was to investigate performance of position, basic controls and additional control for man-machine interface on a 3-point hitch of a tractor. The developed additional control was one-touchup, backup, turnup, liftarm limited, PTO on/off and an external control. As a result of experiment, maximum steady state error of response system was lower than $0.8^{\circ}$ and this result showed the function operated normally because the dead band of system set was ${\pm}1^{\circ}$. There was no abnormal situation by switch operation and sensor signal during the performance test. The results of experiment showed the characteristics of the response was sufficient to be used as the position and additional control system for tractors.