• 제목/요약/키워드: Malposition

검색결과 106건 처리시간 0.027초

족관절 인공관절 치환술 후 발생한 합병증 (Complications after Total Ankle Replacement Arthroplasty)

  • 이경태;양기원;이영구;김진수;박신이;김도연
    • 대한족부족관절학회지
    • /
    • 제12권2호
    • /
    • pp.128-134
    • /
    • 2008
  • Purpose: We evaluated the complications and failures after total ankle arthroplasty during at least 2 years short term follow up. Materials and Methods: There were 45 cases of 42 patients of HINTEGRA$^{{R}}$ (Newdeal SA, Lyon, France) model from November 2004 to August 2006. Follow up averaged at least 2 year. We evaluated the complications and analyzed the cause of the failures. Results: There were totally 15 cases of complication, 5 cases of medial impingement syndrome, 3 cases of varus malposition, 2 cases of delayed healing of wounds, and each one case of deep peroneal nerve problem, medial malleolus fracture, post-operative deep infection, gouty arthritis pain, and Achilles tendinitis. Conclusion: Total ankle arthroplasty had higher complication rate than any other joint arthroplasty, so we need a more meticulous preoperative and peri-operative care.

  • PDF

Jones Jig를 이용한 하악 제 1 대구치 원심이동의 치험례 (Distalization of the lower first molar using Jones Jig)

  • 이상민;김종범;한세현
    • 대한소아치과학회지
    • /
    • 제24권3호
    • /
    • pp.543-548
    • /
    • 1997
  • The first permanent molar takes important place in the occlusion. Malposition of the lower first molar is frequently due to mesial migration, which is occurred by early exfoliation of the second deciduous molar or proximal caries of deciduous teeth. Above things happen without any consideration of space maintainer, prompt measures for space regaining have to be started. Especially in the case with early loss of the second deciduous molar, it has been said that there is no suitable appliance for maintaining the space before the eruption of the permanent first molar. In distalizing the upper first molar, headgears have been routinely used, which its result was definitely depended on cooperation of the patients. Nowadays, appliances such as pendulum appliances, K-loop, magnets, which can be used without cooperation of the patients, are introduced. Jones Jig, one of the molar distalizing appliances, was used on the patients who visited department of pediatric dentistry in Seoul National University Dental Hospital complaining of no eruption space for the lower second bicuspid. Either removable splint or lingal arch was used as the anchorage. Jones Jig was favorably used in the lower molar, where vestibule is shallow, and this is a case report on the satisfactory result thereof.

  • PDF

한방운동요법에 대한 고찰 (The review on exercise therapy of Oriental Medicine)

  • 최재영;정현아;오민석
    • 혜화의학회지
    • /
    • 제19권2호
    • /
    • pp.207-218
    • /
    • 2011
  • Objective : The purpose of this study was to review on exercise therapy of oriental medicine and investigate the effect of Oriental medicine's exercise therapy. Methods : We have researched and analyzed theories and literatures of Oriental medicine's exercise therapy. Result : The following results were obtained in this study. 1. The Doin therapy is one of Oriental medicine's traditional rules for one´s health which based on 'Unity of Heaven and Man'. It grow and supply the 'Qi' for improve health, and connote solution of modern society's various diseases. 2. The Chuna therapy is one of Oriental medicine's traditional therapy that treat harden, set in or malposition of musculoskeletal system 3. Meditation refers to all activities that concentrate the consciousness to current state, have physiological and psychological effects such as pain and stress management. 4. Oriental medicine's exercise therapy connote the strength that apply to medical care for the aged and psychical disorders of modern man. 5. For revitalization of Oriental medicine's exercise therapy, need more active public relations, develop modern methods of Qigong and Significant clinical research on the effects must be carried out. Conclusion : Oriental medicine's exercise therapy can be a solution to various diseases of modern society, and need significant research for revitalization.

이차성 구순열 비첨부 교정 시 내측 및 외측 하부 비익연골의 동시교정술의 필요성과 효용성 (Medial and Lateral Crus Elevation to Correct the Secondary Unilateral Cleft Lip-Nasal Deformities)

  • 박병윤
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.135-143
    • /
    • 2006
  • The characteristics of the cleft lip nasal deformity is defined in this article in three planes. The alar flaring is explained in X axis, the lower positioning of the alar free margin is imagined in Y axis and the short hemicolumella is in Z axis. Most cleft surgeons have focused on the malposition of the lateral crus of alar cartilage while the author defined it in X and Y axises and tried to correct that deformity of short hemicolumella in Z axis. For the last 13 years the author applied that method in 818 cases of secondary cleft lip nose deformity. Through the columellar splitting incision extended to free margin of the alar not beyond the nasal dorsum, the skin and soft tissue of the webbing deformed the nasal tip was excised in crescent fashion. The dissected short hemicolumella including the medial crus was thus elevated and advanced into the space of the deformed nasal tip after the crescent excision. This procedure should be followed by the correction of the deformities in X and Y axis. The medial crus elevation is more effective and critical way to have the constant and nice outcome than the lateral crus reposition in secondary cleft lip nasal deformity

Safety of a Totally Implantable Central Venous Port System with Percutaneous Subclavian Vein Access

  • Keum, Dong-Yoon;Kim, Jae-Bum;Chae, Min-Cheol
    • Journal of Chest Surgery
    • /
    • 제46권3호
    • /
    • pp.202-207
    • /
    • 2013
  • Background: The role of totally implantable central venous port (TICVP) system is increasing. Implantation performed by radiologist with ultrasound-guided access of vein and fluoroscope-guided positioning of catheter is widely accepted nowadays. In this article, we summarized our experience of TICVP system by surgeon and present the success and complication rate of this surgical method. Materials and Methods: Between March 2009 and December 2010, 245 ports were implanted in 242 patients by surgeon. These procedures were performed with one small skin incision and subcutaneous puncture of subclavian vein. Patient's profiles, indications of port system, early and delayed complications, and implanted period were evaluated. Results: There were 82 men and 160 women with mean age of 55.74. Port system was implanted on right chest in 203, and left chest in 42 patients. There was no intraoperative complication. Early complications occurred in 11 patients (4.49%) including malposition of catheter tip in 6, malfunction of catheter in 3, and port site infection in 2. Late complication occurred in 12 patients (4.90%). Conclusion: Surgical insertion of TICVP system with percutaneous subclavian venous access is safe procedures with lower complications. Careful insertion of system and skilled management would decrease complication incidence.

Tapia's Syndrome after Posterior Cervical Spine Surgery under General Anesthesia

  • Park, Chang Kyu;Lee, Dong Chan;Park, Chan Joo;Hwang, Jang Hoe
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권5호
    • /
    • pp.423-425
    • /
    • 2013
  • We present a case report to remind surgeons of this unusual complication that can occur in any surgery, even posterior cervical spine surgery under general anesthesia and discuss its causes, treatment methods, and the follow-up results in the literature. The peripheral Tapia's syndrome is a rare complication of anesthetic airway management. Main symptoms are hoarseness of voice and difficulty of tongue movement. Tapia's syndrome after endotracheal general anesthesia is believed to be due to pressure neuropathy of the vagus nerve and the hypoglossal nerve caused by the endotracheal tube. To our knowledge, no report has been published or given an explanation for Tapia's syndrome after posterior cervical spine surgery. Two patients who underwent posterior cervical surgery complained hoarseness and tongue palsy postoperatively. There is no direct anatomical relation between the operation, the vagus nerves and the hypoglossal nerves, and there is no record of displacement or malposition of the endotracheal tube. After several months, all symptoms are resolved. To avoid this problem in posterior cervical spine surgery, we suggest paying special attention to the position of the endotracheal tube to avoid excessive neck flexion before and during the positioning of the patient.

Improvement of Infraorbital Rim contour Using Medpor

  • Hwang, So Min;Park, Seong Hyuk;Lee, Jong Seo;Kim, Hyung Do;Hwang, Min Kyu;Kim, Min Wook
    • 대한두개안면성형외과학회지
    • /
    • 제17권2호
    • /
    • pp.77-81
    • /
    • 2016
  • Background: Asymmetry of the infraorbital rim can be caused by trauma, congenital or acquired disease, or insufficient reduction during a previous operation. Such asymmetry needs to be corrected because the shape of the infraorbital rim or midfacial skeleton defines the overall midfacial contour. Methods: The study included 5 cases of retruded infraorbital rim. All of the patient underwent restoration of the deficient volume using polyethylene implants between June 2005 and June 2011. The infraorbital rim was accessed through a subciliary approach, and the implants were placed in subperiosteal space. Surgical outcomes were evaluated using preoperative and postoperative computed tomography studies. Results: Implant based augmentation was associated with a mean projection of 4.6 mm enhancement. No postoperative complications were noted during the 30-month follow-up period. Conclusion: Because of the safeness, short recovery time, effectiveness, reliability, and potential application to a wide range of facial disproportion problems, this surgical technique can be applied to midfacial retrusion from a variety of etiologies, such as fracture involving infraorbital rim, congenital midfacial hypoplasia, lid malposition after blepharoplasty, and skeletal changes due to aging.

과잉치를 동반한 상악 중절치 전위와 상악 견치 매복에서 자가이식에 의한 치험례 (AUTOTRANSPLANTATION OF TRANSPOSITIONED MAXILLARY CENTRAL INCISOR WITH MESIODENS AND IMPACTED MAXILLARY CANINE : A CASE REPORT)

  • 남동우;김현정;남순현;김영진
    • 대한소아치과학회지
    • /
    • 제24권4호
    • /
    • pp.727-733
    • /
    • 1997
  • Autotransplantation is a procedure which transplants teeth from the original position to other positions in the same individual. It is classified surgical reposition by intraalveolar autotransplantation and transalveolar autotransplantation. The prognosis for successful autotransplantation is dependent on a number of factors such as root development, surgical technique, patient's age, endodontic treatment, time and type of splinting, preservation of periodontal ligament and storage medium. The most important factor is preservation of periodontal ligament. The cause of the failure of transplantation include damage of the transplant during removal from deep palatal malposition, poor regeneration of the bone around the transplant and chronic periodontal infection. In case I, Impacted maxillary canine for which surgical exposure and orthodontic treatment was impossisle was transplanted. After 2 weeks, It showed periapical radiolucency and external root resorption. So, endodontic treatment was done. One year later, permanent filling was done with gutta percha. In case II, Transpositioned maxillary central incisor was transplanted after extraction of impacted mesiodens. Pulp vitality was maintained during 5 months without other clinical symptons.

  • PDF

혼합치열기의 국소적 치열부정을 위한 Whip Spring (WHIP SPRING FOR THE TREATMENT OF LOCALIZED TOOTH MALPOSITION IN MIXED DENTITION)

  • 김민희;김신;정태성
    • 대한소아치과학회지
    • /
    • 제24권4호
    • /
    • pp.758-762
    • /
    • 1997
  • There are various types of localized tooth malpositions in the mixed dentition, such as abnormal tooth axis, anterior crossbite of some incisors, impaction, midline diastema, ectopic eruption, and so forth. We, Pediatric Dentists, have usually used removable appliances for these instances. But, removable orthodontic appliances, as is known, have marked limitations in some situations, for example, severe rotation, intrusion and extrusion, root torque, closure of large diastema, traction of impacted tooth, etc. In such cases, Whip spring, combined with fixed or removable appliance, can increase utilities of removable orthodontic appliances. The authors have applied whip springs to some cases showing localized positional and arrangement problems, and have witnessed the results as follows; 1. The refined and elaborate control of direction and magnitude of force by the operator, and accurate compliance of the patients were requisite for the treatment with it. 2. It showed special effectiveness for de rotation of incisors. Although it yields some benefit for root movement, the special consideration for incomplete roots in this age bracket was required. 3. In the localized malalignment cases in mixed dentition, uncurable with traditional removable appliances but practically unrealistic with fixed appliance therapy, the whip spring was thought to be a good alternative.

  • PDF

Reconstruction of extended orbital floor fracture using an implantation method of gamma-shaped porous polyethylene

  • Hwang, Woosuk;Kim, Jin Woo
    • 대한두개안면성형외과학회지
    • /
    • 제20권3호
    • /
    • pp.164-169
    • /
    • 2019
  • Background: The conventional surgical method for reconstructing orbital floor fractures involves restoration of orbital continuity by covering an onlay with a thin material under the periorbital region. However, in large orbital floor fractures, the implant after inserting is often dislocated, leading to malposition. This study aimed to propose a novel implanting method and compare it with existing methods. Methods: Among patients who underwent surgery for large orbital floor fractures, 24 who underwent the conventional onlay implanting method were compared with 21 who underwent the novel ${\gamma}$ implanting method that two implant sheets were stacked and bent to resemble the shape of the Greek alphabet ${\gamma}$. When inserting a ${\gamma}$-shaped implant, the posterior ledge of the orbital floor was placed between the two sheets and the bottom sheet was impacted onto the posterior wall of the maxilla to play a fixative role while the top sheet was placed above the residual orbital floor to support orbital contents. Wilcoxon signed-rank test and Mann-Whitney U test were used for data analyses. Results: Compared to the conventional onlay method, the gamma method resulted in better restoration of orbital contents, better improvement of enophthalmos, and fewer revision surgeries. Conclusion: Achieving good surgical outcomes for extended orbital floor fractures is known to be difficult. However, better surgical outcomes could be obtained by using the novel implantation method of impacting a ${\gamma}$-shaped porous polyethylene posteriorly.