• Title/Summary/Keyword: Mal-Operation

Search Result 65, Processing Time 0.028 seconds

A New Algorithm to Reduce the Mal-Operation of DOCR in Bi-directional Power Distribution Systems

  • Jang, Su-Hyeong;Oh, Joon-Seok;Jeong, Ui-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.585-591
    • /
    • 2016
  • DOCR can be used to efficiently increase the reliability and to protect the bi-directional D/L(Distribution Lines). As more DG(Distributed Generation)s attempt to connect the bi-directional D/L, there is an increasing need for studies of how to use DOCR installed in the D/L. This paper investigates the operating principles of DOCR and presents the results an effect of sequence and fault impedance in L-L(Line to Line) fault. An advanced DOCR operating algorithm is proposed to reduce the mal-operation of conventional DOCR. The proposed algorithm is applied to the bi-directional power flow system and shows that it decreases the mal-operation of DOCR through the computer simulation.

배전자동화 개폐기의 Fault Indicator규격 및 운영기법 개선에 관한 연구 (A Study on Improvement of the Specification and Operation Method for Fault Indicator of Distribution Automated Switch)

  • 이중호;하복남;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.861-863
    • /
    • 1998
  • F.I(Fault Indicator) is equipped in automatic switchs for Distibution Automation System(DAS), and plays important role of providing the information for picking out a fault section. The restrictive sentence that F.I doesn't react for the inrush current is in the F.I specification. Nevertheless F.I has sometimes mal-functioned on the DAS in Kang-Dong branch office of KEPCO for latest 2 years. This Paper Proved the causes of the mal-function, and proposed the new F.I specification and operation methods against the mal-function causes.

  • PDF

태양광발전이 연계된 배전계통의 보호기기 오동작에 대한 최적 운용방안에 관한 연구 (A Study on the Optimal Method for Mal-function of Re-closer at the Distribution Feeders Interconnected with PV Systems)

  • 김찬혁;박현석;노대석;신창훈;윤기갑
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1512-1518
    • /
    • 2009
  • Recently, new dispersed power sources such as photovoltaics, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy. This paper deals with the optimal countermeasures for the mal-function of protective devices at primary feeder in distribution systems when new power sources like photovoltaic (PV) systems are interconnected, based on the symmetrical components of short circuit studies. When new power sources are considered to be interconnected to distribution systems, bi-directional power flow and interconnection transformer connection of new power sources may cause the operation problems of protective devices (mainly re-closer), since new power sources can change typical characteristics of distribution systems. Therefore, this paper shows an analysis skill of the mal-functional mechanism of protective relay and proposes the optimal solution for the mal-function problem using the symmetrical components of fault analysis. And, this paper also shows the effectiveness of proposed method by the simulation at the field distribution systems.

On the Necessity of Cavity-type Coupling Mechanism for obtaining Circular Polarization with Microstrip Patch Antenna

  • Abegaonkar, Mahesh P.;Cho, Young-Ki
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.459-463
    • /
    • 2003
  • A circularly polarized microstrip patch antenna (MPA) using electromagnetic (EM) coupled fed method is analyzed in view of the two types of coupling mechanisms viz. cavity and parasitic type, proposed earlier. The patch-ground plane distance is varied in order to achieve the fore-mentioned types of couplings. For each case of patch-ground plane distance, the offset position of feedline is optimized for perfect matching and the boresight axial ratio (AR) is observed. It is seen that CP operation is possible only for cavity-type coupling (smaller patch-ground plane distances). The simulated results for the boresight AR for the two types of coupling mechanisms are presented.

  • PDF

송전선로 보호용 디지털 지능형 거리계전기 (Digital Adaptive Distance Relay for Transmission Line Protection)

  • 정창호;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권9호
    • /
    • pp.411-416
    • /
    • 2001
  • Distance relay is the most widely used in transmission line protection because it is applicable not only as main protection but also as back-up protection. However, the protection range of the distance relay is always fixed in the unchangeable operating range while the power system varies, and therefore the distance relay is the device that is the highly influenced by the power system changes. In this regard, this paper describes an approach to minimize the mal-operation of the distance relay due to the power system changes through changing protection range of the distance relay into optimal condition in response to the load variation and power system condition. Also mal-function of the distance repay in case of high resistance ground faults could be minimized through modeling the protection range into quadratic function.

  • PDF

Esophageal Injury Following Anterior Cervical Plate Fixation

  • Park, Jae-Sung;Kim, Young-Baeg;Hong, Hyun-Jong;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권2호
    • /
    • pp.141-145
    • /
    • 2005
  • We report five patients of esophageal injuries confirmed by clinical signs and radiological evidences. They include a partial tear and a perforation which were not noticed during the operation, a perforation which was primarily repaired during the operation, and two perforations which occurred during the reoperations for the removal of mal-positioned screws or plate. The partial tear was not repaired. The perforation which occurred during the operation was primarily sutured and didn't receive further treatment. Two perforations which occurred during the reoperations were treated by irrigation, debridement with surgical drainage, and systemic antiobiotics. One who was diagnosed later after the operation showed the poorest outcome and required longest hospital days among our series. Early detection and appropriate treatment of esophageal injury following anterior spinal surgery can only improve the prognosis by preventing secondary complications.

DC제거용 FIR필터가 거리계전기에 미치는 영향 분석 (The Influence of a FIR Filter on Distance Relaying Algorithm)

  • 오예준;장준;박진규;김수환;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2195_2196
    • /
    • 2009
  • DC-offset is a very important subject in power systems protection, since DC-offset causes mal-operation of the distance relay. This paper deals with the influence of a FIR filter used for removing the DC-offset upon the convergence characteristics of distance relaying algorithm based on Fourier Transform.

  • PDF

복선구간의 단선운행 방안 시뮬레이션 (Single line Operation in a double line)

  • 정의진;김종기;이재호;조봉관;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.384-386
    • /
    • 1998
  • In the emergency case such as a single line operation in a double line section because of a line broken or train's mal-operation, single line equipments that can operate without a line indication are needed. The main purpose of this study is to verify and analyze the availability of the single line operation that is able to operate without the indication of up or down line, and to offer a realizably alternative method to improve this situation. In order to carry out this study, we concentrated on getting related information. And to adopt the single line operation to existing line, the technology survey of other countries signalling system and the technical analysis of the interior signalling equipment were performed. As a result of this study, the required system and effect of the single line operation system were represented.

  • PDF

복구조정 활동과 복구조정 후 시간경과에 따라 퇴화하는 작업시간을 갖는 단일기계의 일정계획에 관한 연구 (A Study on Single Machine Scheduling with a Rate-Modifying Activity and Time-Dependent Deterioration After the Activity)

  • 김병수;주철민
    • 경영과학
    • /
    • 제30권1호
    • /
    • pp.15-24
    • /
    • 2013
  • We consider the single machine scheduling problem with a rate-modifying activity and time-dependent deterioration after the activity. The class of scheduling problems with rate-modifying activities and the class of scheduling problems with time-dependent processing times have been studied independently. However, the integration of these classes is motivated by human operators of tasks who has fatigue while carrying out the operation of a series of tasks. This situation is also applicable to machines that experience performance degradation over time due to mal-position or mal-alignment of jobs, abrasion of tools, and scraps of operations, etc. In this study, the integration of the two classes of scheduling problems is considered. We present a mathematical model to determine job-sequence and a position of a rate-modifying activity for the integration problem. Since the model is difficult to solve as the size of real problem being very large, we propose genetic algorithms. The performance of the algorithms are compared with optimal solutions with various problems.