• Title/Summary/Keyword: Maintenance energy

Search Result 1,388, Processing Time 0.04 seconds

공동주책의 에너지소비와 이산화탄소 배출특성

  • 이윤규;이강희
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.868-877
    • /
    • 2001
  • This study is to present the typical energy consumption criteria and $CO_2$ exhaust rate in multi-family housing complex by analyzing the energy consumption characteristics. The contents and methodology of this study are as follows; -Examining the documents of maintenance accounts, investigate the cost and its items expended by the annual maintenance in multi-family housing complex. -Survey each consumption of energy sources, maintenance area, location of multi-family housing complex, heating type, and so forth. -After classifying with heating type of multi-family housing complex investigated, Scrutinize the energy consumption by each source. -Analyze the characteristics of energy consumption and $CO_2$ exhaust through multiple regression analyses of maintenance property. -Suggest the typical energy consumption criteria (Mcal/$m^2$.year, Mcal/house.year) and $CO_2$ exhaust rate (kg-c/$m^2$.year, Kg-c/house.year) in multi-family housing complex. the results will come into basic data for estimating energy consumption in multi-family housing complex according to maintenance characteristics.

  • PDF

Tele-robotic Application for Nozzle Dam Maintenance Operation in Nuclear Power Plants

  • Seo, Yong-Chil;Kim, Chang-Hoi;Cho, Jae-Wan;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1520-1524
    • /
    • 2004
  • This paper describes the development of a robotic maintenance system for use in a maintenance operation of the nozzle dam in a water chamber of a steam generator at the Kori nuclear power plant in Korea. The robotic maintenance system was designed to minimize the personnel exposure to a hazardous radioactive environment. This robotic maintenance system is operated by a teleoperated control which was designed to perform the nozzle dam maintenance tasks in a remote manner without endangering the human workers. Specific maintenance tasks involve the transportation, insertion, and removal of nozzle dams in a water chamber inside a steam generator via a narrow man-way entrance port. The developed robotic maintenance system has two major subsystems: a two degrees of freedom guiding device acting as the main guiding arm and a master-slave manipulator with a kinematic dissimilarity. The mechanical design considerations, control system, and capabilities of the robotic maintenance system are presented. Finally, a graphical representation of the nozzle dam maintenance processes in a simulated work environment are also demonstrated.

  • PDF

Analysis of cavity expansion based on general strength criterion and energy theory

  • Chao Li;Meng-meng Lu;Bin Zhu;Chao Liu;Guo-Yao Li;Pin-Qiang Mo
    • Geomechanics and Engineering
    • /
    • v.37 no.1
    • /
    • pp.9-19
    • /
    • 2024
  • This study presents an energy analysis for large-strain cavity expansion problem based on the general strength criterion and energy theory. This study focuses on the energy dissipation problem during the cavity expansion process, dividing the soil mass around the cavity into an elastic region and a plastic region. Assuming compliance with the small deformation theory in the elastic region and the large deformation theory in the plastic region, combined with the general strength criterion of soil mass and energy theory, the energy dissipation solution for cavity expansion problem is derived. Firstly, from an energy perspective, the process of cavity expansion in soil mass is described as an energy conversion process. The energy dissipation mechanism is introduced into the traditional analysis of cavity expansion, and a general analytical solution for cavity expansion related to energy is derived. Subsequently, based on this general analytical solution of cavity expansion, the influence of different strength criterion, large-strain, expansion radius, cavity shape and characteristics of soil mass on the stress distribution, displacement field and energy evolution around the cavity is studied. Finally, the effectiveness and reliability of theoretical solution is verified by comparing the results of typical pressure-expansion curves with existing literature algorithms. The results indicate that different strength criterion have a relatively small impact on the displacement and strain field around the cavity, but a significant impact on the stress distribution and energy evolution around the cavity.

Development of the Preventive Maintenance Template for Static Exciter in the Nuclear Power Plant (원자력발전소 정지형 여자기의 예방정비기준(PMT) 개발)

  • Chin, Soo-Hwan;Park, Jin-Youb;Hong, Young-Hee
    • Journal of Energy Engineering
    • /
    • v.20 no.2
    • /
    • pp.154-162
    • /
    • 2011
  • PMT(Preventive Maintenance Template) is a standardized maintenance program that describes maintenance items & period as operation condition to increase component reliability at the component level. The existing maintenance programs are focused on time based maintenance to inspect and repair component depend on fixed period. But recently, we have developed advanced maintenance program(named PMT) to increase reliability and optimize maintenance program of the plant significant component. This paper presents how to develop the PMT for nuclear power plant's static exciter.

A Bridge Transported Bilateral Force-Reflecting Servo-Manipulator for Maintenance of Nuclear Pyroprocessing Equipment

  • Park, B.S.;Jin, J.H.;Ko, B.S.;Lee, J.K.;Yoon, J.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2226-2230
    • /
    • 2005
  • The Advanced Spent Fuel Conditioning Process (ACP), which is a pre-disposal treatment process for spent fuel is being developed at the Korea Atomic Energy Research Institute (KAERI). The ACP equipment is operated in an intense radiation field as well as in a high temperature. Thus, the equipment is designed in consideration of the remote handling and maintenance. This paper describes a Bridge Transported Bilateral Force-Reflecting Servo-Manipulator (BTSM) system, which is being developed to overcome the limitation of access that is a drawback of the mechanical Master-Slave Manipulators (MSMs), which are mounted on the ACP hot cell wall for the operation and the maintenance of the ACP equipment. The BTSM system was manufactured and temporally installed at the mockup to test its performance. The manufactured BTSM system will be installed at the ACP hot cell on June 2005 after the accomplishment of the performance test. The BTSM system consists of four components: a transporter with a telescoping tubeset, a slave manipulator, a master manipulator, and a remote control system. This system will highly increase the volume of coverage for the operation and maintenance of the ACP equipment.

  • PDF

Enteric methane emissions, energy partitioning, and energetic efficiency of zebu beef cattle fed total mixed ration silage

  • Subepang, Sayan;Suzuki, Tomoyuki;Phonbumrung, Thamrongsak;Sommart, Kritapon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.4
    • /
    • pp.548-555
    • /
    • 2019
  • Objective: The main objective of this study was to evaluate the effect of different feeding levels of a total mixed ration silage-based diet on feed intake, total tract digestion, enteric methane emissions, and energy partitioning in two beef cattle genotypes. Methods: Six mature bulls (three Thai natives, and three Thai natives - Charolais crossbreeds) were assigned in a replicated $3{\times}3$ Latin square design, with cattle breed genotype in separate squares, three periods of 21 days, and three energy feeding above maintenance levels (1.1, 1.5, and 2.0 MEm, where MEm is metabolizable energy requirement for maintenance). Bulls were placed in a metabolic cage equipped with a ventilated head box respiration system to evaluate digestibility, record respiration gases, and determine energy balance. Results: Increasing the feeding level had no significant effect on digestibility but drastically reduced the enteric methane emission rate (p<0.05). Increasing the feeding level also significantly increased the energy retention and utilization efficiency (p<0.01). The Thai native cattle had greater enteric methane emission rate, digestibility, and energy utilization efficiency than the Charolais crossbred cattle (p<0.05). The daily metabolizable energy requirement for maintenance in Thai native cattle ($388kJ/kg\;BW^{0.75}$, where $BW^{0.75}$ is metabolic body weight) was 15% less than that in Charolais crossbred cattle ($444kJ/kg\;BW^{0.75}$). Conclusion: Our results suggested that the greater feeding level in zebu beef cattle fed above maintenance levels resulted in improved energy retention and utilization efficiency because of the reduction in enteric methane energy loss. The results also indicated higher efficiency of metabolisable energy utilization for growth and a lower energy requirement for maintenance in Bos indicus than in Bos taurus.

ENERGY REQUIREMENTS OF GROWING SAHIWAL × FRIESIAN HEIFERS IN MALAYSIA

  • Liang, J.B.;Samiyah, M.N.;Azizan, A.R.;Dollah, M.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.1
    • /
    • pp.75-79
    • /
    • 1992
  • Fourteen Sahiwal ${\times}$ Friesian crossbred heifers were used in a 10-wk feeding trial to determine maintenance energy requirements and efficiency of gain. The heifers were individually fed with a diet consisting of 30% dry grass and 70% concentrates at either 110, 140 or 180% of the anticipated maintenance requirement ($494kJ\;ME/kg^{0.75}/day$). Liveweight of individual heifers was measured weekly to calculate diet requirements and average daily gain (ADG). Diet digestibility was determined for all heifers to determine ME intake. Retained energy (RE) of individual heifers was determined from changes in total body fat and protein using a TOH isotope dilution procedure and, assuming calorific values of 39.3 and 23.6 kJ/g for fat and protein respectively. The estimated ME for maintenance was 433 and $470kJ/kg^{0.75}/day$ by liveweight (ADG) equilibrium and energy (RE) equilibrium analysis respectively. ME requirement for one g of liveight gain was 28 kJ.

A Study on Process for District Office Building Maintenance with EPIQR+ (on Focusing Energy and Economics Evaluation) (EPIQR+를 이용한 구청사 건물에 대한 경제적, 에너지관점에서의 건물 재평가)

  • Kim, Tae Han
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.13-20
    • /
    • 2009
  • This study suggested practical application of decision aid tool on re-evaluation of current buildings with a focus on a energy and economics evaluation methodology. In Europe, over forty percent of all construction activities are for retrofit. For efficient construction, various tools for re-evaluating existing buildings have been developed and are in use. Legislations of relevant laws and studies are actively initiated. In particular, EPIQR (Energy Performance Indoor environment Quality Retrofit), which was developed through the EU's Third and Fourth Framework Programs laid a foundation on a new concept-based decision aid tool for re-evaluation of existing buildings. As for actual applications, based on this, EPIQR+ was developed to be in line with a building maintenance guideline (SIA 469) and is actively applied to public buildings. This tool quantifies the degree of damages of existing buildings and suggests alternatives to users in energy (SIA 380/1) and economical perspectives. This study examined these preceding tools and suggested some trenchant approaching for more comprehensive and efficient use of re-evaluation tools in building maintenance.

Effects of Feeding Levels Above Maintenance Energy on Nutrients Digestibility and Energy Value in Hanwoo Steers (유지에너지 이상의 사료공급이 거세 한우의 영양소 소화율 및 에너지가에 미치는 영향)

  • Ryu, Chae-Hwa;Lee, Sung-Dae;Lee, Seul;Baek, Youl-Chang
    • Korean Journal of Organic Agriculture
    • /
    • v.31 no.4
    • /
    • pp.461-468
    • /
    • 2023
  • Supplying an appropriate amount of feed is an economical and environmentally friendly by increasing the nutrient digestibility of livestock and reducing nutrients released from overfeeding. Therefore, this study was conducted to determine the nutrient digestibility according to dietary feeding levels of Hanwoo steers. Three treatments in feeding trial were used feeding amount based on the maintenance energy level of the Korean feeding standard for Hanwoo (2022): 100% (control, CON), 140% (treatment 1, TRT1), and 190% (treatment 2, TRT2). The experiment was designed in replicate 3×3 balanced Latin square designs using six Hanwoo steers. In this study, energy value was predicted according to treatment groups. In addition, nutrient digestibility and energy value were measured through a feeding trial to Hanwoo steers. All energy values, including total digestible nutrients and digestible energy, were predicted to decrease linearly with increasing feeding levels. TRT2 showed lower digestibility than CON for dry matter, crude protein, non-fiber carbohydrates, and total digestible nutrients in the feeding trial (p<0.05). However, there was no significant difference between CON and TRT1. Total digestible nutrients (TDN) and digestibility of feed are set based on the maintenance energy. However nutrient digestibility and TDN decreased when feeding level increased by more than 190% compared to maintenance energy in this study. Therefore, it is necessary to correct the TDN by considering the feeding level when mixing the feed.

Hardware-Oriented Reliability Centered Maintenance for the Diesel Generators of Wolsong Unit 1

  • Bae, Sang-Min;Park, Jin-Hee;Kim, Tae-Woon;Lee, Yoon-Kee;Song, Jin-Bae
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.587-591
    • /
    • 1997
  • The DGs (Diesel Generators) in NPP (Nuclear Power Plant) has been used for the emergency electric power source to shut down the nuclear reactor safely in case of station blackout. The RCM (Reliability Centered Maintenance) has been applied to DGs for increasing the safety of NPP. The structured defects of DG were not remedied by the improvement of maintenance method. As the first stage of RCM, to find the structured defects, its failure modes were searched and analyzed through the ten year maintenance information. The structured defects such as the air compressor, the lubricating oil pressure, and the insufficient load were the root causes of main failures. The air reservoir reinstallation, the lubricating oil tube modification, the load bank installation, and the qualitative instrumentation were the solutions for the hardware oriented RCM of DGs. There remains the software oriented RCM such as the rejection of useless maintenance, the preventive maintenance, the database of maintenance information, and the predictive maintenance.

  • PDF