• 제목/요약/키워드: Maintenance Water

검색결과 1,608건 처리시간 0.029초

중랑천의 수서동물에 관한 생태학적 연구 (An Eclogical Study on the Aquatic Animals in Jungrang Stream of Seoul)

  • 배경석;박종태;조기찬;길혜경;신재영
    • 한국환경보건학회지
    • /
    • 제23권2호
    • /
    • pp.89-97
    • /
    • 1997
  • Most of urban streams in Korea have been changed channel forms and suffered from direct inflow of domestic sewage, etc. Therefore, maintenance of structure and function of those ecosystem are hard. The present study was carried out to examine the life survival maintenance ability of the stream by community analysis of aquatic animals in typical urban stream (Jungrang stream) in Seoul. The aquatic animals were composed of 31 species, 18 families, 8 orders, 5 classes in 4 phyla. Seasonal species number showed big fluctuation between 8 species in Winter and 24 species in Autumn. Major dominant species in Jungrang stream were Tubificidae sp.1, Chironomidae sp.1, Chironomidae sp.2 and Physa acuta, and above endurance species for water pollution occupied very high dominance indices. But, Cercion hieroglyphicum, Ischnura asiatica, Rantra chinensis, Herochares striatus, Agabus japonicus in benthic macroinvertebrates of a few individuals are appeared. Also, fry of Carassius auratus and Silurus asotus in fish are occurred. Therefore, we can be inferred on posibility of growth and spawning of above species in the stream. Jungrang stream has a small quantity of natural riffle areas, ponds and watergrass areas by channel form of water course. Aquatic animals in Jungrang stream has been suffered by reduction of self-purification reaction ability and have mass production of attached algae on the stream bed. For analysis of fluctuation of life survival maintenance ability in Jungrang stream, long-term survey is needed.

  • PDF

예방적 유지보수를 위한 소수성 저점도 AP 표면처리재 개발 (The Development of the Hydrophobic - Low Viscosity Filling Material for the Surface Treatment for Pavement Preventive Maintenance)

  • 최준성;김조순
    • 한국도로학회논문집
    • /
    • 제16권2호
    • /
    • pp.35-41
    • /
    • 2014
  • PURPOSES : Surface treatment is a favorable method in the pavement preventive maintenance. This study (Part I) aimed to develop the low viscosity filling material for waterproof characteristics and high penetrable and weather resistance, and a series of companion study (Part II) presents the coating characteristics and performance analysis using field and lab tests. METHODS : Hydrophobic characteristics of the advanced surface treatment material are observed and measured the filling depth and the permeability for sand and asphalt pavement specimen using the water absorption test and permeability test, X-RAY CT test. Color difference for the weather resistance using ultraviolet ray accelerated weathering test is compared with asphalt pavement specimens. RESULTS : The developed material shows the decreased water absorption and increased impermeable effect because of the hydrophobic characteristics. It is found that the filling depth is about 6mm and weather resistance is better than asphalt pavement specimen. CONCLUSIONS : The advanced hydrophobic - low viscosity filling treatment material is developed in this study (Part I) to improve the waterproof characteristics and high filling capacity and weather resistance for the pavement preventive maintenance.

통합형 인-라인 오일 모니터링 센서의 제철설비 현장 적용사례 (Case Study on Integrated In-line Oil Monitoring Sensor for Machine Condition Monitoring of Steel Making Industry)

  • 공호성;한흥구;곽진수;장원수;임경근
    • Tribology and Lubricants
    • /
    • 제26권1호
    • /
    • pp.73-77
    • /
    • 2010
  • One of the important trends for condition monitoring in the 21st century is the development of smart sensors that will permit the cost-effective continuous monitoring of key machine equipments. In this study, an integrated in-line oil monitoring sensor assigned for continuous in situ monitoring multiple parameters of oil performance is presented. The sensor estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical density of oil in three optical wave-bands ('Red', 'Green' and 'Blue') and water content is evaluated as relative saturation of oil by water. In order to evaluate the sensor's effectiveness, the sensor was applied to several used oil samples in steel making industry and the results were compared with those measured by standard test methods.

수력발전소 자동제어설비의 현대화 (The Modernization of Automatic Control facilities of Hydro Power Plant)

  • 권오극;권영준;송영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.69-70
    • /
    • 2008
  • Automatic control systems(AVR, Governor, Synchronizer) installed $1970{\sim}1980$ in K-water were considered to be rehabilitated around 2000. Moreover, Korea Power Exchange market system was changed from PPA (Power Purchase Agreement) to a bidding system. Therefore, depending on the power quality, the power provider could achieve additional profits. It is the excitation system and governor that have the functions of enhancing power necessities. During the 20 to 30 years of generator operation, there were many major and minor problems. Examples are SCR burnout (Andong: Excitation system), hunting (Imha: governor), field circuit breaker failure (Chungju 1st: excitation system), the rise of leakage current (Chungju 2nd: excitation system), power supply burnout (Chungju 2nd: governor). These are the typical examples of malfunction which hindered the generator operation and, consequently, diminished the profit of power business. In order to satisfy the needs of the power market and prevent malfunctions mentioned above, the rehabilitation of AVRs and governors were executed. A new system was made to have the flexibility of ancillary service (GF, AGC, etc.), PSS function. With user friendly HMI software, it is more convenient for the operator to fulfill suitable maintenance. It was possible to connect SCADA system by opening protocol of AVR, governor for the efficiency of operation and maintenance.

  • PDF

교면포장 및 바닥판 손상방지를 위한 내부침투수 처리시스템 개발 (A Development of the Trapped Water Drainage System to Prevent the Deterioration of Deck Slab and Pavement)

  • 이상달;이상순;신재인;서상길
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.233-239
    • /
    • 2002
  • Reinforced concrete deck slabs are directly affected by traffic loads and they are also susceptible to weather-related problems, such as cracking, reinforcement corrosion, spatting, scaling, delamination, leakage, efflorescence and so on. Some of these defects are caused by water which seeps through pavements and trapped between pavements and deck slabs. For durability of reinforced concrete deck slabs and pavements, it is very important to protect deck slabs and drain the trapped water out. To develop the trapped water drainage system, the following studies have been performed in Korea Highway Cooperation: related researches a re reviewed; for six bridges, deck slabs are thoroughly investigated; new system to effectively drain the trapped water out is proposed; the proposed system is installed and evaluated. The proposed system is proved to be effective to drain the trapped water out and is expected to increase the durability of reinforced concrete deck slabs.

댐 안전관리를 위한 조압수조의 규모 결정 (Determination of Surge Tank Scale for Dam Safety Management)

  • 이호진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.164-174
    • /
    • 2007
  • 댐에서 관로 시스템을 효과적으로 설계하기 위해서는 수격작용과 같은 과도수리현상을 해석해야 만 한다. 일반적으로 조압수조는 터빈의 부하변화에 의한 과도수리현상에 의해 발생되는 압력의 변화를 감소시키기 위해서 사용된다. 본 연구에서는 댐 안전관리를 위한 조압수조의 적정규모를 조사하였다. 지배방정식을 이용하여 조압수조 내 수위변동을 계산하였다. Thoma-Jaeger의 안정조건을 사용하여 홍수위, 상시만수위, 정격수위, 저수위인 경우에 정적안정조건과 동적안정조건을 검토하였다. 끝으로 조압수조의 수직갱과 수실의 적정 지름을 결정하였다.

가동중 정비를 위한 Risk Monitor 개발 (Risk Monitor Development for On-Line Maintenance)

  • 김길유;한상훈;김태운
    • 한국안전학회지
    • /
    • 제12권4호
    • /
    • pp.21-26
    • /
    • 1997
  • Korea Atomic Energy Research Institute (KAERI) developed a risk monitor called Risk Monster which supports for plant operators and maintenance schedulers to monitor plant risk and to avoid high peak risk by rearranging maintenance work schedule. Risk Monster can update the plant risk continuously according to the change of system/component configuration since Risk Monster reevaluates the plant risk based on the Probabilistic Safety Assessment (PSA) results. A brief description of Risk Monster is provided. The PSA model of UCN 3, 4 nuclear power plant was converted by KAERI to Risk Monster model. Using this Risk Monster model, a feasibility study of the on-line maintenance of an Essential Service Water (ESW) pump was performed. On-line maintenance of one ESW pump has been shown to be acceptably safe, and has economic benefits. In addition, it is not a violation of technical specification to continue plant operation with an out-of-service ESW pump.

  • PDF

Maintenance of Waterscape Facilities at Garden shows in Korea

  • Lee, Kyong-bok;Hong, Kwang-pyo;LEE, Hyuk-jae
    • International Journal of Advanced Culture Technology
    • /
    • 제8권4호
    • /
    • pp.189-199
    • /
    • 2020
  • We aimed to understand various problems identified at waterscape facilities of gardens built at garden shows in Korea. The main purpose of the study is to understand which parts of waterscape facility built in gardens at garden shows are causing problems and whether these problems can be traced back from garden design phase or from local communities in charge of maintenance. Furthermore, we examined if such problems get more aggregated as time passes by and different garden shows have different types of problems. In this study, types of waterscape facilities examined are pond, waterway, wall fountain, water glass, trough, mist, Cascade, fountain, rain garden, waterfall. An analysis of the maintenance status of waterscape facilities introduced in the existing gardens confirmed that problems could arise in two main respects. One is due to poor maintenance by the organizers of the garden show, and the other is due to the poor design of waterscape facilities by the garden designer.

다공성 세라믹과 제올라이트를 활용한 수질정화미디어블럭의 효과 연구 (A Study on Water Purification Effect of Media Block Using Porous Ceramics and Zeolite)

  • 전성률;구본학
    • 한국환경복원기술학회지
    • /
    • 제20권5호
    • /
    • pp.59-66
    • /
    • 2017
  • Preeminent water treatment plans are essential to preserve the water quality of aquatic biotopes. Previous studies have not been sufficient to provide cost-effective maintenance method since they focused only on the purification of deteriorated water that requires a continuous supply of clean water. This study proposes an economical method of water quality maintenance using water treatment media block constructed vertically using porous ceramics, zeolite, and river pebble. The water treatment media block does not require a separate purification area because it functions as a purifier within the ecological pond which can maximize the biotope area. To evaluate the performance of the water treatment media block, we longitudinally tracked the change of water quality indicators (pH, TDS, COND, DO, T-P, T-N, COD) suggested by Water Environment Standards, Ministry of Environment, Republic of Korea. We compared the water quality of one control (A: general ecological pond composition method of the laminated structure) and two experimental groups (B: a combination of aquatic plants and a water treatment media block, C: a water treatment media block only). As a result, we confirmed that the water treatment media block is an efficient and economical method to maintaining the water quality of the ecological pond for a long time. The water treatment media block will be a great help in providing a better aquatic biotope space for aquatic insects and fishes living in clear water.