• Title/Summary/Keyword: Maintenance Grade

Search Result 217, Processing Time 0.026 seconds

Evaluation of Deterioration Grade for Remodeling Architectural Facilities in Old Schools (학교건물(學校建物) 건축설비(建築設備)시스템의 노후도(老朽度) 평가(評價) 기준(基準)마련을 위한 기초연구(基礎硏究))

  • Cho, Min-Kwan;Cho, Chang-Geun;Park, Jong-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.4
    • /
    • pp.15-23
    • /
    • 2006
  • The purpose of this study is to establish the objective deterioration grades and evaluation criteria of building equipment system of educational facilities available for reasonable maintenance and remodeling of them. For the purpose of it, the actual conditions of building equipment systems of the 148 buildings of 84 middle and high schools in Seoul 20 years after construction are investigated and surveyed through one-on-one interviews and questionnaires. And, deterioration grades of them are estimated by the evaluation criteria which is proposed in this study. As a result of this study, the 10 deterioration grades and the 4 evaluation criteria of the 6 performances of building equipment system, which are heating and cooling, water supply and drainage, hot water supply and electrical power performance, are suggested. And, as a result of the survey, it showed that 24% of the investigated school buildings were estimated C grade which needs partial remodelling, and 51% of the school buildings were estimated D grade which needs extensive remodelling. And, 25% of the school buildings were estimated E grade which needs overall remodelling or alteration of building equipment system.

Vascular Plants of Construct-Reserved Site of Ecological Stream, Sohyeoncheon in Gyeongju-si (경주시 생태하천 예정지인 소현천의 관속식물상)

  • You, Ju-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.21 no.5
    • /
    • pp.61-79
    • /
    • 2018
  • The purpose of this study is to investigate the flora of Sohyeoncheon which is planned for ecological restoration and river maintenance from upstream to downstream, and also to collect the ecological data to cope with the change of the ecosystem of Sohyeoncheon. The numbers of vascular plants were summarized as 336 taxa including 82 families, 233 genera, 298 species, 1 subspecies, 33 varieties and 4 forms. The rare plants were 3 taxa including Aristolochia contorta Bunge, Prunus yedoensis Matsum.(planting) and Koelreuteria paniculata Laxmann. The Korean endemic plants were 4 taxa including Populus tomentiglandulosa T.B.Lee(planting), Lespedeza maritima Nakai, Forsythia koreana (Rehder) Nakai(planting) and Weigela subsessilis (Nakai) L.H.Bailey. The specific plants by floristic region were 15 taxa including 1 taxon of grade V, grade IV and grade II each, 4 taxa of grade III and 8 taxa of grade I. The naturalized plants were 60 taxa and the invasive alien plants were 3 taxa. The results of analysis by vertical structures showed that naturalized plants included 31 taxa of upstream, 53 taxa of midstream and 38 taxa of downstream. An analysis of crossing structures showed that 2 taxa of water channel, 3 taxa of low waterside, 41 taxa of high waterside and 48 taxa of bank.

Vascular Plants Distributed in Bukcheon Stream, Urban Stream in Gyeongju-si (경주시의 도시하천인 북천에 분포하는 관속식물상)

  • You, Ju-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.6
    • /
    • pp.87-107
    • /
    • 2020
  • The purpose of this study is to present the basic data for maintenance and management of river ecosystem by surveying and analysing the kinds and their characteristics of vascular plants in Bukcheon stream, Gyeongju-si, South Korea. The numbers of vascular plants were summarized as 428 taxa including 92 families, 265 genera, 3 subspecies, 24 varieties, 6 forms, 5 hybrids and 5 cultivars. Among the identified taxa, there were 90 planted species. The endangered wild species was Cicuta virosa, and the rare plants were 5 taxa including Prunus × yedoensis, Juniperus chinensis L. var. sargentii and so on. The Korean endemic plants were 5 taxa Populus × tomentiglandulosa, Salix koriyanagi, Lespedeza maritima, Forsythia koreana and Aster pseudoglehni. The specific plants by floristic region were 26 taxa including 2 taxa of grade V, 3 taxa of grade IV, 2 taxa of grade III, 8 taxa of grade II and 11 taxa of grade I. The naturalized plants were 81 taxa including Euphorbia maculata, Erigeron strigosus, Vulpia myuros and so on. The invasive alien plants were 7 taxa including Humulus scandens, Rumex acetosella, Ambrosia artemisiifolia, Ambrosia trifida, Lactuca seriola, Symphyotrichum pilosum and Paspalum distichum.

Low-Grade Fibromyxoid Sarcoma Arising in Posterior Nasal Cavity: Case Report and Review of the Literature (후비강에서 발생한 저등급의 섬유점액성 육종: 증례 보고 및 문헌 고찰)

  • Sohn, Jung Heob;Lee, Kijin;Cho, Kyoung Rai
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.11
    • /
    • pp.624-629
    • /
    • 2018
  • Low-grade fibromyxoid sarcoma (LGFMS), a soft tissue tumor that has high recurrence and metastasizing potential, rarely occurs in the head and neck region. Therefore, the treatment for LGFMS in the facial area is challenging in terms of cosmetic and functional maintenance. The authors report a case of LGFMS in the posterior nasal cavity. It was completely removed in parallel with the nasal endoscopic and oral approach, but the lower margin was closed by preserving the soft palate. The patient is well without any recurrence or metastasis after 5 years of follow-up.

Life Cycle Cost Optimization Considering Maintenance History of Bridge Beck and Girders (바닥판과 주형의 유지보수 이력을 고려한 LCC 최적설계)

  • Ahn Ye-Jun;Lee Hyun-Sub;Shin Yung-Seok;Park Jang-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.719-726
    • /
    • 2005
  • The optimal design was performed for the bridge superstructure composed of steel box girders and concrete deck considering life cycle cost. The service life of the superstructure was estimated, after load carry capacity curves for steel girder and concrete deck were derived on the basis of condition grade curves and maintenance histories. The object function was determined as life cycle cost, including initial cost, total maintenance cost, disposal cost and user cost, for a period of the estimated service life. The optimal design of the superstructure was performed for the various service lifes. The annual costs were used to compare calculated results and to get the most economical design. Also this paper presents reasonable idea for the use of user cost with uncertainty.

  • PDF

Development and application effect analysis of sound insulation materials between floors focusing on maintenance performance (유지관리 성능중심의 층간차음재 개발 및 적용효과 분석)

  • Yang, Jin-Kook;Park, Young-Duk;Kim, Ki-Nam;Lee, Seok-Bong;Yun, Jeong-No
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.63-64
    • /
    • 2022
  • Inter-floor noise in an apartment building is a serious problem that causes conflicts between tenants. Accordingly, there are various attempts to solve this problem, but it is not easy to find a clear solution. Therefore, in this study, a soundproofing material between floors was developed that can improve the sagging that occurs after construction. And as a result of testing the developed interlayer soundproofing material, both light weight and weight were grade 1. And it was analyzed that maintenance performance could be improved with integrated structural characteristics.

  • PDF

Analysis of Structural Safety for Rebar Exposure and Corrosion in PSC I-Girder Bridge Slab (PSC I형 교량 바닥판의 철근노출 및 부식에 대한 구조적 안전성 분석)

  • Han, Manseok;Park, Ju-Hyun;Lee, Jong-Han;Min, Jiyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.67-74
    • /
    • 2021
  • This paper evaluated the structural safety of an aging PSC I-girder bridge with rebar corrosion in the deck. The geometry and rebar of the bridge were designed based on an actual PSC I-girder bridge, and the numerical analysis was performed considering the crack of concrete and yielding of steel rebar. According to the evaluation criteria of Korea Infrastructure Safety and Technology Corporation, this study defined two criteria of rebar exposure and corrosion rates to construct a total of 32 corrosion scenarios. Rebar exposure was defined as the exposure of tensile rebars in the bridge deck due to the removal of cover concrete. The results of the analysis showed that the safety and rating factors of the bridge decreased with increasing rebar exposure and corrosion rates. For the rebar corrosion rate more than 50%, the safety grade of the bridge should be carefully evaluated for all the rebar exposure rate. When the rebar corrosion rate exceeds 57%, the bridge was evaluated as E grade regardless of rebar exposure rate. A correlation analysis for a 2% of rebar exposure rate found that the bridge was evaluated as A grade up to 55.8% corrosion rate, C grade up to 56.9%, D grade up to 58.5%, and E grade for corrosion rate greater than 58.5%. This study indicates the necessity of a quantitative evaluation of rebar corrosion for evaluating the structural safety of aging bridges.

Study on the Improvement of Waterproofing Performance Rating for the Introduction of Residential Apartment Complex Performance Grade Index (공동주택 성능등급 표시제도 강화를 위한 방수성능 등급 도입에 관한 연구)

  • An, Ki-Won;Cho, Il-Kyu;Oh, Sang-Keun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.41-49
    • /
    • 2018
  • The current housing performance rating system displays the performance rating of the houses supplied by the housing construction company, approved by the Housing Law. This system is intended to provide accurate information to the consumers in the announcement of the tenant recruitment, thereby improving the quality of the housing. This system was revised in January 2005 and implemented from January 2006. It is obligatory for companies with a scale of more than 1,000 households (energy performance rating is over 300 households), but there is currently no content on the waterproofing field. Therefore, this study suggests the revision plan proposes the necessity of the inclusion of the performance grade for the waterproofing field which is not currently implemented in the apartment house performance rating system, and to understand how to secure an adequate living environment. As a result, according to survey results, the performance score based on the difficulty of the maintenance method according to future leaks was selected and the revised system was prepared. Based on this, the performance grade for the virtual apartment was evaluated, and the results show that the performance of various grades is presented accordingly.

Experimental Study on Effect of Confinement Details for Lap Splice of Headed Deformed Reinforcing Bars in Grade SD400 and SD500 (구속상세가 SD400 및 SD500 확대머리 이형철근의 겹침이음에 미치는 영향에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.62-71
    • /
    • 2015
  • KCI 2012 and ACI318-11 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. In ACI318-11, the confinement factor, such as transverse reinforcement factor, is not used to calculate the development length of headed bars. The purpose of this experimental study is to evaluate the effect of confinement details to the lap splice performance of headed deformed reinforcing bars in grade SD400 and SD500. The confinement details are stirrups and tie-down bars in lap zone. Test results showed that specimens with only stirrups had the brittle failure and could not increase lap strengths, and that specimens with composite confinements by stirrups and tie-down bars had the flexural strengths over than nominal flexural strengths. Stirrups with tie-down bars can have an effect on improvement in lap splice of headed bars in grade SD400 and SD500.

Intra-arterial and Intravenous Tirofiban Infusion for Thromboembolism during Endovascular Coil Embolization of Cerebral Aneurysm

  • Kim, Sang Heum;Kim, Tae Gon;Kong, Min Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.518-526
    • /
    • 2017
  • Objective : Thromboembolism is the one of the most serious complications that can occur during endovascular coil embolization of cerebral aneurysm. We report on the effectiveness and safety of intra-arterial/intravenous (IA/IV) glycoprotein IIb/IIIa inhibitor (tirofiban) infusion for treating thromboembolism during endovascular coil embolization of cerebral aneurysm. Methods : We performed a retrospective analysis of 242 patients with ruptured or unruptured cerebral aneurysms (n=264) who underwent endovascular coil embolization from January 2011 to June 2014. Thromboembolism occurred in 20 patients (7.4%), including 14 cases of ruptured aneurysms and 6 cases of unruptured aneurysms. The most common site of aneurysms was the anterior communicating artery (n=8), followed by middle cerebral artery (n=6). When we found an enlarged thromboembolism during coil embolization, we tried to dissolve it using tirofiban administered via IA and IV loading ($5{\mu}g/kg$, respectively) for 3-5 minutes followed by IV maintenance ($0.08{\mu}g/kg/min$) for approximately 4-24 hours. Results : In 4 of 5 patients with total vessel occlusion, the vessel was recanalized to Thrombolysis in Cerebral Infarction Perfusion Scale (TICI) grade 3, and in 1 patient to TICI grade 2a. In 2 patients with partial vessel occlusion and 13 patients with minimal occlusion, the vessel recanalized to TICI grade 3. Irrelevant intracerebral hemorrhage was noted in 1 patient (5%), and thromboemboli-related cerebral infarction developed in 5 patients (25%), of which only 1 (5%) was symptomatic. Conclusion : IA/IV infusion and IV maintenance with tirofiban appear to be an effective rescue treatment for thromboembolism during endovascular coil embolization in patients with ruptured or unruptured cerebral aneurysms.