A Study on the Improvement of Member Evaluation Method in the Condition Evaluation of Reinforced Concrete Buildings (철근콘크리트 건축물의 상태평가 중 부재평가방법 개선에 관한 연구)

  • Woo, Hye-Sung;Yi, Waon-Ho;Hwang, Kyung-Ran;Lee, Kwan-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.85-91
    • /
    • 2021
  • Type 1 and type 2 buildings must regularly conduct precise safety inspections and precise safety diagnosis for the safety and maintenance of facilities, and the safety grade of the building is determined according to the results of the implementation. In addition, the cycle of inspection and diagnosis is determined according to the safety grade of the building. In order to determine the safety grade of the building, a precise safety inspection conducts condition evaluation, and a precise safety diagnosis conducts condition evaluation and safety evaluation. Therefore, since the inspection and diagnosis cycle is determined according to the safety grade of the building, the condition evaluation and safety evaluation must be precise. However, in the case of member unit evaluation, which is the first step in evaluating the current condition, the evaluation grade is determined by using the representative value of the measurement result, and this may result in an error in the evaluation grade. To solve this problem, this study analyzed evaluation criteria for each evaluation item and presented evaluation criteria using inequalities to respond to measurement results and evaluation scores. In addition, we present a functional formula that can reflect performance scores for each evaluation item.

Legislative and policy issues related to the advancement of the maintenance system of water resource facilities (수자원시설물의 유지관리 체계 선진화를 위한 입법 및 정책과제)

  • Lee, Giha;Yeon, Minho;Lee, Daeeop;Kim, Seongwon;Kim, Jinsoo
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.spc1
    • /
    • pp.773-784
    • /
    • 2020
  • In this study, legislative and policy issues related to advancing the maintenance system of water resource facilities were presented by investigating and analyzing the degree of aging and management status of water resource facilities. Data from the comprehensive Facility Management System (FMS) operated by the Korea Infrastructure Safety Corporation were collected and used to analyze the aging of water resource facilities. Using safety grade data categorized by facility, type, local area, and grade, the ratio of dangerous facilities and the aging rate were calculated to analyze the status of water resource facilities and guidelines and manuals related to water resource facilities were investigated. Through this, four required actions to address legislative and policy issues were presented: 1) Readjusting the scope of water resource facilities and supplementing guidelines and manuals, 2) Establishing a maintenance system considering changes in disaster conditions, 3) Improving the FMS and activating standard linkage services, and 4) Establishing a facility asset management system.

Understanding of DB-Load (DB-하중에 관한 이해)

  • Lee, Jong-Man
    • Journal of the Korean Professional Engineers Association
    • /
    • v.42 no.1
    • /
    • pp.44-48
    • /
    • 2009
  • About past 30 years, we don't have enough consideration and investigation about DB-Load. While 30 years, weight of truck is heavier and condition of roads differ, so many conditions of roads and vehicles are changed. We must consider change of many conditions and we must improve laws about maintenance of DB-Load. and now we must consider that low grade as well as high grade bridge can cross heavy vehicle and harmony between changed size of vehicle and bridge while making laws and code. So we can apply to improve design properly.

  • PDF

Relationship between Span/Steel Grade and Fatigue Strength of Steel Railway Bridges (강철도교의 지간/강종과 피로강도의 관계)

  • Kwon, Soon-Cheol;Kyung, Kab-Soo;Youn, Cheol-Hee;Lee, Jun-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1074-1079
    • /
    • 2007
  • It is important to evaluate the effect in the maintenance of steel bridge because the fatigue of the bridge is affected by the structural characteristic of bridge such as structure type, span and steel grade, etc. In this study, we analyzed the effect of fatigue strength by the changes of span of the bridge and the steel grade in many factors which have influence on the fatigue life of the bridge. For this analysis, we selected the objective bridges and performed the structural analyses for the various parameters such as span and steel grade. The fatigue evaluations were carried out by FAST which is a program for fatigue estimation and the results were compared.

  • PDF

Identifying latent classes about the changing trajectories of child maltreatment by child developmental period (아동발달시기별 아동학대 변화궤적 유형 비교 연구)

  • Han, Jihyeon;Choi, Okchae
    • Journal of the Korean Society of Child Welfare
    • /
    • no.59
    • /
    • pp.183-208
    • /
    • 2017
  • The purpose of this study was to identify groups depending on the change trajectory of child maltreatment in childhood and early adolescence. For this study, the data from waves two through six (2011-2015) of the Korean Children and Youth Panel Survey (KCYPS) were used. Participants included first-grade (n=2,300) and fourth-grade (n=2,325) elementary school students. A latent class growth model (LCGM) using Mplus 7.21 was adopted to classify the types of developmental trajectories of child maltreatment. The main results were as follows: First, in physical abuse, childhood from the second to the sixth grades was classified into four groups: decreased, low maintenance, increased, and no maltreatment type. In addition, early adolescence from the fifth grade of elementary school to the third grade of middle school was also classified into the same types. Second, in emotional abuse, childhood was classified into three groups: decreased, increased, and no maltreatment type. Early adolescence was classified into four groups: decreased, low maintenance, increased, and no maltreatment type. Third, in neglect, childhood was classified into four groups: maintenance, low decreasing, low increasing, and no maltreatment type. Early adolescence was classified into three groups: maintenance, low increasing, and no maltreatment type. According to the change of child maltreatment by developmental period, physical abuse continued from childhood to early adolescence, whereas emotional abuse and neglect increased in early adolescence compared to childhood. This study is meaningful in classifying latent classes depending on maltreatment types. Theoretical and practical implications were suggested based on the study results.

A study on the Longitudinal Force Variation of CWR according to the Condition of Track Maintenance (궤도보수 작업 조건별 장대레일 축력변화에 관한 연구)

  • Won, Yong-Hoan;Kim, Kwan-Hyung;Kwon, Soon-Jung;Lee, Seung-Youl
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.99-105
    • /
    • 2009
  • This research presents the method to decide proper locations for destressing of CWR using a non-destructive equipments to measure the longitudinal force(installation temperature) in CWR. The effect and necessity of destressing were analyzed by estimating changes of longitudinal force. The installation temperature was measured to find changes of longitudinal force in high speed and conventional lines before and after destressing or track maintenance at the locations where destressing was planed or where change of longitudinal force was expected during track maintenance. Past destressing was carried out within qualitative decision criteria. This research proposes the quantitative criteria to decide the priority order of the destressing locations reasonably by considering the difference of air temperature and stress free temperature during the track maintenances, the grade of ballast resistance force recovering and the length of destressing, etc.

  • PDF

A System Dynamics Model for Evaluation of Maintenance Cost Policy in Deteriorated School Building (노후 학교건물의 유지관리비용 정책 평가를 위한 시스템 다이내믹스 모델)

  • Kang, Suhyun;Kim, Sangyong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.12
    • /
    • pp.181-188
    • /
    • 2019
  • The maintenance of school building is pivotal issue. However, it is difficult to obtain basic analysis data for LCC(Lifecycle Cost) analysis and maintenance planning of school building. Therefore, this study proposed System Dynamics(SD) techniques to make maintenance decisions for school building. The interaction between the major parameters related to the aging of a building, maintenance activities, and cost were expressed in Causal Loop Diagram. Based on this, the formula for the relationship between causal maps was defined and converted to Stock and Flow Diagram. Through the completed SD model the 50-year plan of 214 educational building were tested by considered in account budget, maintainability, and budget allocation opinions. As a result, the integrated SD model demonstrated that it can support strategic decision making by identifying the status class and LCC behavior of school buildings by scenario. According to the scenario analysis, the rehabilitation action of preventive maintenance that primarily repairs the buildings in condition grade C showed the best performance improvement effect relative to the cost. Therefore, if the proposed SD model is expanded to consider the effects of other educational policies, the crucial performance improvement budget can be estimated in the long-term perspective.

A Study on Trail Deteriorations and Management in University Forest of Chungnam National University (충남대학교 학술림 산책로 훼손실태 및 관리방안에 관한 연구)

  • Lee, Joon-Woo;Kim, Myeong-Jun;Choi, Yeon-Ho;Jeon, Yong-Jun;Oh, Do-Kyo;Kim, Min-Ho;Lee, So-Yeon;Lee, Kyoung-Hyoung
    • Korean Journal of Agricultural Science
    • /
    • v.31 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • This study concentrates on the trail of the CNU(Chungnam National University) forest. The amount of use and the pattern of damage are considered, as well as the extent of environmental damage. Finally, some managerial strategies are proposed in connection with sustainable maintenance. The trail of the university forest is composed of three sections; one is the neighborhood park and the Institute of Information Technology/Communications, the second is the Institute of Information Technology/Communications and the Dormitory, and the third section is the Dormitory and the Foreign prof's Apt. The total length of the trail is 2.6km. The daily amount of use is 1,269 visitors per day. The amount of using increased three times the amount of that in 1998. This study shows the pattern of damage of the trail in the order of root-exposure, widening, rock-exposure, deepening and the divergence in the frequency of occurrence of all these factors. Environmental damage is also graded thus: grade 3 is 27.4m, grade 4 is 0.8m, grade 5 is 1.5m, and grade 6 is 0.2m. Accordingly, some managerial strategies were proposed in connection with the sustainable trail maintenance.

  • PDF

Elementary School Children's Trajectories of Self-Esteem in Grades 1 through 4 (초등학교 1~4학년의 자아존중감 변화궤적 및 잠재계층유형)

  • Seul Gi Ko;Sang Lim Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.581-587
    • /
    • 2023
  • The purpose of this study was to analyze the change trajectory and latent class types of self-esteem in first to fourth grade elementary school students. For the purpose, the Korean Children's Panel data were analyzed using potential growth model and the growth mixture model. As the results, the linear change model was selected as the most appropriate model. The change trajectory was found to increase slightly as the grade increased. In addition, four latent class groups were derived through: 'high level-maintenance,' 'low level-increase,' 'high level-decrease,' and 'low level-maintenance.' Most children were in the 'high level-maintenance' group, followed by 'high level-decrease,' 'low level-increase,' and 'low level-maintenance' groups. Therefore, based on the results of the study, we suggest that educational institutions and local communities pay attention to trends in elementary school students' self-esteem and provide appropriate support for students in each class.

Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures (생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료)

  • Kwon, Duck-Joo;Lee, Yong-Beom;Shin, Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF