공동주택에서의 바닥충격음 인지도 분석 (The Analysis of Perceptual Levels For Floor Impact Noises in Apartments)

  • 김경호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.598-603
    • /
    • 2002
  • The floor impact noise in apartment buildings has been known as the most sensitively recognized environmental noise. Therefore. inhabitants perceptual evaluation of floor impact noises was investigated by a questionnaire survey. It was found that the respondents perceive the floor impact noises from the upper nor as a constant noise level. However, if there is any child on the upper floor. the respondents felt Its noise as a harshly grating level. It was also found that the larger the respondents house is. the higher their wanted level of noise isolation is. Moreover, it was revealed that the main source of the floor impact noise from the upper floor is a child at the age from six to seven. The results could be used as fundamental data for the research on impact sources and new regulations that fit to Korean perceptual aspects and characteristics.

  • PDF

공동주택 바닥충격음의 차음성능 평가 (Evaluation of Floor-Impact Sound Insulation for Apartment Buildings)

  • 윤세철;오종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.932-937
    • /
    • 2003
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among accupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for seven apartment buildings. The floor-impact sound levels were measured for seventeen On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

  • PDF

완충재의 종류에 따른 공동주택 바닥충격음 차단성능에 관한 실험연구 (An Experiment Study on Floor-Impact Sound Insulation by Resilient Materials in Apartment Buildings)

  • 윤세철;오종민
    • 환경영향평가
    • /
    • 제14권4호
    • /
    • pp.217-225
    • /
    • 2005
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for nine apartment buildings. The floor-impact sound levels were measured for twenty-five On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

수음실 내 구조체의 진동량 계측을 통한 바닥충격음레벨 예측 (Prediction of Floor Impact Sound by Measuring the Vibration Acceleration Level on the Interior Structures of Receiving Room in Apartment Buildings)

  • 김명준;김흥식;김하근
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.3-9
    • /
    • 2003
  • In an apartment building, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation. it is nesessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to investigate the applicability of the theory of sound radiation. We measured the vibration acceleration levels on the interior structures and predicted the sound pressure level of the room by using them. The result show that the predicted value, in general, were in good agreement with the measured values within 5∼10% in error rate.

중량 바닥충격음 예측을 위한 진동 전달률 산정 연구 (Assessment of Vibration Transmissibility for Prediction of Heavy Floor Impact Sound)

  • 김하근;김명준;오양기
    • 한국소음진동공학회논문집
    • /
    • 제13권6호
    • /
    • pp.415-422
    • /
    • 2003
  • In an apartment buildings, the floor Impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation, it is necessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to suggest the supplementary formula(equation) and constant k considering vibration transmissibility in order to predict more precisely heavy floor impact sound by Impedance Method that have been briskly studied in Japan from comparing the measured values with the predicted values. The analyzed results had showed that if the damping material was glass wool or rubber, k=5 was proper and if the damping material was polystyrene foam, k>5 was desirable.

층간소음 어노이언스에 대한 설문조사 (Questionnaire Survey on Annoyance of Floor Impact Sound)

  • 정정호;이평직;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.262-265
    • /
    • 2006
  • In order to investigate characteristics of floor impact sound generated in the apartment buildings, questionnaire survey was conducted for respondents living in apartments in 200t. Questions in the surrey were on the characteristics of real impact sounds, subjective annoyance and satisfaction on the heavy and light impact sources. From the survey results, it was found that most annoying time of a day and the space were 8 p.m. to midnight at living room. It was also revealed that the main source of the floor impact sound from the upper floor is a child's jumping and running at from six to nine. More than half of people were not satisfied on the floor impact isolation performance of their own apartments. The percentage of residents who were annoyed by the heavy-weight impact sound such as children's jumping and adult's walking was $5{\sim}10%$ lower than by light-weight impact sound. In addition, females being responded more annoyed by floor impact sound than males.

  • PDF

중량충격원 충격에 따른 공동주택 실내공간의 구조음장 해석 모델링방법에 관한 연구 (A Study on the Structural-acoustic Analysis Modeling Methods of the Room with Heavy Impact Noise Source)

  • 이재광;구해식
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of the present study is to establish structural noise analyzing method for apartments building floor with structural-acoustic coupling analysis modeling. Noise through floor in the room is recognized as a significant problem with the consequence that noise isolation technique has been studied in the various fields of industry. From among noise factors, resonance sound is the main reason for solid noise of the floor, which is occurred by mechanical vibrations of the acoustic boundary line and the change of velocity. To analyse this phenomenon, numerical computation methods are provided in many fields, In this study, evaluation method for slab is established using finite element method, and a case study for analyzing acoustic phenomenon was suggested. The results show that numerical method, especially F.E.M, has a good approximation to predict noise at floors.

유한 요소법을 이용한 나 슬래브의 2차원 바닥 충격진동 해석 (2-Dimensional Floor Impact Vibration Analysis in Bare Reinforced Concrete Slab Using Finite Element Method)

  • 서상호;전진용
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.604-611
    • /
    • 2005
  • The relationship between floor impact sound and vibration has been studied by field measurements, and the vibration modal characteristics have been analyzed. Vibration levels impacted by a standard heavy-weight impact source have been predicted according to the main design parameters using finite element method. Experimental results show that the dominant frequencies of the heavy impact sounds range below 100 Hz and that they are coincident with natural frequencies of the concrete slab. In addition, simple 2-dimensional finite element models are proposed to substitute 2 types of 3-dimensional models of complicated floor structural slabs those by The analytical result shows that the natural frequencies from first to fifth mode well correspond to those by experiments with an error of less than $12\%$, and acceleration peak value iscoincident with an error of less than $2\%$. Using the finite element model. vibration levels areestimated according to the design Parameters, slab thickness, compressive strength, and as a result, the thickness is revealed as effective to increase natural frequencies by $20\~30\%$ and to reduce the vibration level by 3$\~$4 dB per 30 mm of extra thickness.

임피던스법을 이용한 보이드 슬라브의 개선방안에 관한 연구 (The Study of Improvement of the Void Slab Applying the Impedance Method)

  • 오재응;김영식
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.276-284
    • /
    • 2001
  • In apartment buildings, floor-impact sound has been regarded as the major source that causes complaints from residents. It is mainly due to the use of light-weight structures and the lack of researches in terms of floor-impact sound. The purposes of this study are analyzing the characteristics of vibration response and sound radiation of 12type void slabs in the improvements void slab by impedance method and finding the fittest improvements void slab on the 12type void slab. The main results of this study are summarized as below: (1) In the $\frac{1}{3}$ octave band level of sound radiation, $\frac{1}{3}$ octave band levels, measured from four-divided improvement void slab(No.8) and eight-divided improvement void slab(No.12), are 10~25 dB lower than that of standard void slab(No.1) in the 1250 Hz. Especially, eight-divided improvement void slab(No.12) is the best void slab in terms of radiation efficiency of sound level. (2) In the correlation relation of acceleration and sound radiation, standard void slab(No.1), four-divided improvement void slab(No.8), SK standard four-hole void slab(No.10), and eight-divided improvement void slab(No.12) are positive correlation relation.

  • PDF

도로교통소음에 관한 기존 예측식 평가 및 검증에 관한 연구 (A Study on the Evaluation and Verification of an existing Prediction Model on the Road Traffic Noise)

  • 이내현;조일형;박영민;선우영
    • 환경영향평가
    • /
    • 제15권2호
    • /
    • pp.93-100
    • /
    • 2006
  • In general, the verification to prediction formula in a national road and the main street of a town has been used recklessly in Korea. Therefore we investigated the validity of an existing prediction formula (NIER(87, 99), TR-Noise, KLC(2002)) with correction relationship which was based on both the prediction formular from apartment complex in the field and height 1.5m from the surface level. On the results of measuring the noise level form an isolated distance, the noise level showed that it was 4.5~5.5dB(A) by reason of becoming 2 folder far from a source. From the distribution of noise level measured by the apartment floors, the measurement point (1st floor) was 58.7~71.4dB(A) at its lowest level and the middle floors (3, 5, 7 and 10) were the highest distribution of noise level. From the analysis results on the application validity to an existing prediction formular (NIER(87, 99), TR-Noise, KLC(2002)) in the height 1.5m, the correction coefficients were 0.95~0.96 and the measured values were reasonably close to the predicted values, indicating the validity and adequacy of the predicted models. KLC(2002) model was found accurate within 3dB(A) with 36 data out of the total 42 data, showing the most accuracy among the predict models. However, the developed models have to improve the accuracy with a various of factors.