• 제목/요약/키워드: Main plate

검색결과 883건 처리시간 0.023초

열교환기 관판의 전지작용부식과 방지에 관한 연구 (A Study on the Galvanic corrosion and its Protection on Heat Exchanger Tube Plate)

  • 임우조;홍성희;윤병두
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.344-350
    • /
    • 2001
  • This paper was studied on the characteristics of galvanic corrosion and its protection on heat exchanger tube plate in the sea water. In this paper, behavior of pitting corrosion of Ni-al bronze connected with Ti tube was measured af flow velocity of 0 m/s and 2.4 m/s. To protect galvanic corrosion, the protection characteristics of Ni-Al bronze connected with Ti tube by Zn-base alloys galvanic anode and hexagonal nylon insert was investigated. Main results obtained asre al follows: 1) The galvanic corrosion of Ni-Al bronze connected with Ti-tube is more active than single Ni-al bronze. 2) As the circuit resistance increase under the cathodic protection employing Zn-base alloys galvanic anode, Ni-al bronze connected with Ti tube is cathodically unpolarized. 3) The corrosion of Ni-Al bronze connected with Ti tube by nylon insert controls approximately 73% than not nylon insert.

  • PDF

열교환기 관판의 전지작용부식과 방지에 관한 연구 (A Study on the Galvanic corrosion and its Protection on Heat Exchanger Tube Plate)

  • 임우조;홍성희;윤병두
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.345-345
    • /
    • 2001
  • This paper was studied on the characteristics of galvanic corrosion and its protection on heat exchanger tube plate in the sea water. In this paper, behavior of pitting corrosion of Ni-al bronze connected with Ti tube was measured af flow velocity of 0 m/s and 2.4 m/s. To protect galvanic corrosion, the protection characteristics of Ni-Al bronze connected with Ti tube by Zn-base alloys galvanic anode and hexagonal nylon insert was investigated. Main results obtained asre al follows: 1) The galvanic corrosion of Ni-Al bronze connected with Ti-tube is more active than single Ni-al bronze. 2) As the circuit resistance increase under the cathodic protection employing Zn-base alloys galvanic anode, Ni-al bronze connected with Ti tube is cathodically unpolarized. 3) The corrosion of Ni-Al bronze connected with Ti tube by nylon insert controls approximately 73% than not nylon insert.

헬륨을 이용한 열유속센서 검정방법의 실험적 연구 (An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas)

  • 양훈철;송철화;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF

수치시뮬레이션에 의한 박판 용접 변형 예측에 관한 기초적 연구 (A Fundamental Study on Forecast of the Thin Plate Welding Deformation by Numerical Simulation)

  • 김종명;박창수;김영표;방한서
    • Journal of Welding and Joining
    • /
    • 제21권1호
    • /
    • pp.93-98
    • /
    • 2003
  • For construction of steel structures, thin steel plates have been often used and welding is the main manufacturing process. However, welding processes cause some problems(welding residual stresses, welding deformations, etc.). In these problems, welding deformation is extremely harmful to the safety of structures especially. Therefore, in this study, a numerical analysis program based on large deformation plate theory has been developed to analyze and predict the welding deformation in thin plates. From the result of numerical analyse, we can find two parameters, thermal cycles and mechanical restraints affecting the welding deformation of structures. It is considered that large difference of thermal cycles and mechanical restraints in the width direction bring about welding deformation. Results of simulation have the same tendency of deformation distribution in width direction as experimental formulas.

방전간극변화가 오존생성특성에 미치는 영향 (The Effects of Discharge Gap Variation for Ozone Generation Characteristics)

  • 이상근;전병준;박용권;박원주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.135-138
    • /
    • 2001
  • Recently, ozone is utilized In various fields and its needs are expanding. therefore, so many ozone generation methods have been reported in the latest years, its main purpose Is to get the high ozone concentration and to improve the ozone yield. One of them is a plate-type ozone generator. In this paper, the plate-type ozone generator is piled up many folds(3 and 5 electrodes). Ozone concentration and yield were investigated in accordance with power, quantity of supplied gas and gap spacing of plate electrodes.

  • PDF

최적 요크를 갖는 자기변형 그레이팅을 이용한 고출력 주파수 튜닝 평판 SH 파 발생 (Magnetostrictive Grating with an Optimal Yoke for Generating High-Output Frequency-Tuned SH Waves in a Plate)

  • 김우철;김익규;김윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.71-74
    • /
    • 2007
  • The objective of this presentation is to introduce a recent development of a magnetostrictive grating technique using an optimal yoke to efficiently generate and measure SH (Shear-Horizontal) waves in a plate. Gratings are effective means to generate frequency-tuned waves, but the gap between magnetostrictive gratings inevitably obstructs magnetic flow. Because magnetic field is the main physical quantity to actuate and sense ultrasonic waves, the transducer performance is most significantly influenced by the magnetic field distribution in the strips. Thus, wave transduction efficiency can be substantially improved if better magnetic flow is formed in the strips. To improve the efficiency, the topology optimization method was used to determine an optimal yoke configuration. A series of experiments on an aluminum plate were conducted using a grating with and without the designed yoke; when the yoke was used, the signal outputs increased up to 60 %.

  • PDF

A Preliminary Study on a Method for the Morphological and Quantitative Analyses of Individual Snow Crystals and Its Application for Field Measurement

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권3호
    • /
    • pp.196-203
    • /
    • 2011
  • The main aim of this study is to establish methods of morphological preservation and elemental quantification for individual snow crystals. Individual snow crystals were collected at a height of 20 m above ground level. To stabilize and preserve the original morphologies of the snow crystals, cyanoacrylate, which has been used to fix liquid droplets, was applied (Kasahara et al., 2000). Several different kinds of snow crystals (dendrite, sectored plate, quasi-sectored plate, and hexagonal plate) were successively stabilized using this method. The stabilized snow crystals were pretreated with acetone, and then the elemental components contained in a whole snow crystal were quantified with the Particle Induced X-ray Emission (PIXE) analytical technique. The snow crystal residual composition determined in the present study was dominated by sulfur and mineral components, and the elemental mass showed an apparent crystal size dependence, where the elemental mass gradually decreased as the crystal size increased.

단조하중을 받는 SC 전단벽의 휨강도 평가 (Flexural Strength Evaluation of Steel Plate Concrete Shear wall subject to Monotonic Loading)

  • 권민호;김진섭;서현수;임정희
    • 복합신소재구조학회 논문집
    • /
    • 제4권4호
    • /
    • pp.9-14
    • /
    • 2013
  • In this study, flexural strength properties of SC shear walls were investigated through static pushover test. Failure modes and stiffness characteristics of SC shear walls under lateral loads were inspected by analyzing the experimental results. Main failures of unstiffened SC shear walls were found to be the type of bending shear failure due to the unbonding of the steel plate at the concrete interface. The ductility capacity of SC structures was also confirmed to be improved, which is considered to be a confining effect on steel plates in the longitudinal behavior of SC shear walls.

GUST 중에서의 2차원 수중익 해석 (An analysis of Two-Dimensional Hydrofoil in Gust)

  • 김형태;이창섭;양승일
    • 한국기계연구소 소보
    • /
    • 제4권2호
    • /
    • pp.49-63
    • /
    • 1982
  • In this paper, a classical gust problem is treated by using the numerical lifting¬-surface theory to verify the effect of gust-a sudden fluctuating fluid velocity around an object, which is normal to the main stream direction-on the hydrody¬namic forces, especially the mean thrust in upstream direction, acting on the two¬-dimensional flat plate. In this case, the mean thrust wholly resorts to the leading edge suction, and it is the same situation to the case of the heaving plate in uniform flow. The ph¬enomenon of leading edge suction is very important for the flapping propulsion of animals, typical to fish and birds, and can be related to the prediction of the hydrodynamic forces acting on marine propellers operating in gustlike wakes of ships. The results of this paper can be easily superposed to those of the reference [1J in order to solve the problem of the two-dimensional oscillacting plate in gust

  • PDF

시스템 식별법을 이용한 평판 진동 제어에 관한 연구 (A Study on Plate Vibration Control using System Identification)

  • 이재호;정준홍;박기헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.99-101
    • /
    • 2005
  • This paper is concerned with the active vibration control of flexible plate system using $H_2$ controller. The main objective of this paper is to propose the system identification for estimation dynamic equation of plate vibration system and control algorithm such as $H_2$ controller design. In this paper dynamic equation is determined by considering only the first, second, and third vibration modes, and experiments confirm that this model works well. The $H_2$ control algorithm is proposed and implemented on the experimental setup to show their efficacy. Effectiveness and performance of the designed controller was verified by both simulation and experiment result.

  • PDF