• 제목/요약/키워드: Main lobe

검색결과 175건 처리시간 0.027초

Side lobe free medical ultrasonic imaging with application to assessing side lobe suppression filter

  • Jeong, Mok Kun;Kwon, Sung Jae
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.355-364
    • /
    • 2018
  • When focusing using an ultrasonic transducer array, a main lobe is formed in the focal region of an ultrasound field, but side lobes also arise around the focal region due to the leakage. Since the side lobes cannot be completely eliminated in the focusing process, they are responsible for subsequent ultrasound image quality degradation. To improve ultrasound image quality, a signal processing strategy to reduce side lobes is definitely in demand. To this end, quantitative determination of main and side lobes is necessary. We propose a theoretically and actually error-free method of exactly discriminating and separately computing the main lobe and side lobe parts in ultrasound image by computer simulation. We refer to images constructed using the main and side lobe signals as the main and side lobe images, respectively. Since the main and side lobe images exactly represent their main and side lobe components, respectively, they can be used to evaluate ultrasound image quality. Defining the average brightness of the main and side lobe images, the conventional to side lobe image ratio, and the main to side lobe image ratio as image quality metrics, we can evaluate image characteristics in speckle images. The proposed method is also applied in assessing the performance of side lobe suppression filtering. We show that the proposed method may greatly aid in the evaluation of medical ultrasonic images using computer simulations, albeit lacking the use of actual experimental data.

단원형배열안테나의 합차 모노펄스 주엽 식별 (Main-Lobe Recognition for Sum-Delta Monopulse of Single-Ring Circular Array Antenna)

  • 박현규;우대웅;김재식
    • 한국군사과학기술학회지
    • /
    • 제26권2호
    • /
    • pp.122-128
    • /
    • 2023
  • The target must be located within the main-lobe of the antenna in order to measure the direction of the target by using sum-delta monopulse technique. The most common way if the target is located within the main-lobe is to compare the amplitude of the sum channel received signal with the delta channel received signal. However, in the case of the single-ring circular array antenna, it is difficult to apply the conventional method due to its structural limitation where antenna elements do not exist in the center of the array. In this paper, we proposed a novel method to identify whether a target is located within the main-lobe by appropriately adjusting the feeding amplitude of each element constituting the single-ring circular array antenna through the particle swarm optimization method. Simulation results showed that the proposed method can determine whether the target is located within the main-lobe of the single-ring circular array antenna.

완전 디지털 능동위상배열 안테나의 효과적인 부엽 차단 빔 형성 방법 (An Effective Method to Form Side-Lobe Blanking Beam of Fully Digital Active Phased Array Antenna)

  • 주정명;박종국;임재환;이재민
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권4호
    • /
    • pp.59-65
    • /
    • 2022
  • 본 논문에서는 디지털 능동위상배열 안테나를 간략히 소개하고 주 빔의 부엽을 차단하기 위해 적용된 이중 채널 부엽 차단 빔 형성 방법에 대해 기술하였다. 그리고 안테나 주 빔 및 부엽 차단 빔 설계 결과와 안테나 근접전계 측정 결과로부터 안테나 성능을 검증하였다. 다음으로 기존의 이중 채널 부엽 차단 빔 운용 방식 보다 채널수를 줄이기 위해 단일 채널 부엽 차단 빔 형성 방법을 제안하고, 제안한 방법으로 부엽 차단 안테나에 대한 소자별 가중치 분포를 설계하였다. 마지막으로 설계된 단일 채널 부엽 차단 빔 패턴과 차단 능력을 검증하고 이중 채널 부엽 차단 빔과 비교하였다. 또한, 디지털 능동위상배열 안테나의 수신 근접전계 시험을 통해 측정한 이중 채널 부엽 차단 빔과 제안된 단일 채널 부엽 차단 빔 패턴 및 부엽 차단 성능을 비교/검증함으로써 제안된 부엽 차단 빔 형성 방법에 대한 유효성을 확인하였다.

의료용 초음파 영상 시스템에서 채널신호의 스펙트럼에서 거리 가중치를 이용한 부엽의 억제 (Suppression of side lobe using distance weight in spectrum of channel signal in medical ultrasound imaging system)

  • 이유림;정목근
    • 한국음향학회지
    • /
    • 제42권3호
    • /
    • pp.203-213
    • /
    • 2023
  • 의료용 초음파 영상 시스템에서, 영상점의 밖에서 오는 신호가 초음파 수신 집속 과정에서 완전히 제거되지 않으면 부엽을 발생시킨다. 부엽의 시간 신호가 영상점에서 오는 시간 신호(주엽)와 같이 중첩되어 나타나면 시간 영역에서 필터 처리를 이용하여 완전히 제거하기 어렵다. 그러나 수신 집속 과정에서 시간 -채널 신호를 푸리에 변환하면, 주엽과 부엽의 신호는 주파수 스펙트럼 영역에서 공간적으로 분리가 된다. 따라서 스펙트럼 영역에서 계산한 주엽과 부엽의 신호크기를 이용하여 크기 가중치를 계산하여 영상에 곱함으로써 부엽을 억제하였다. 그리고 주엽과 부엽의 스펙트럼이 인접할 때, 주엽과 부엽 스펙트럼 사이의 거리에 따라 거리 가중치를 적용하였다. 64 채널 선형 트랜스듀서를 사용하는 5 MHz의 초음파 영상 시스템에서 점확산 영상과 다른 밝기의 낭종을 가지는 스페클 영상을 합성하고 가중치를 적용하여 초음파 영상을 계산하였다. 점반사체 영상에서 해상도의 변화 없이 부엽이 크게 줄어들었으며 낭종 영상에서 대조도가 크게 개선됨을 컴퓨터 시뮬레이션으로 확인하였다.

원, 타원 및 인벌루트 조합된 치형형상을 갖는 로터 개발 (Development of an Automated Design System for Oil Pumps with Multiple Profiles(Circle, Ellipse and Involute))

  • 정성윤;김문생;조해용;김철
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.103-112
    • /
    • 2009
  • A internal lobe pump is suitable for oil hydraulics of machine tools, automotive engines, compressors, constructions and other various applications. In particular, the pump is an essential machine element of an automotive engine to feed lubricant oil. The subject of this paper is the theoretical analysis of internal lobe pump whose the main components are the rotors: usually the outer one is characterized by lobe with elliptical and involute shapes, while the inner rotor profile is determined as conjugate to the other. And the integrated system which is composed of three main modules has been developed through AutoLISP under AutoCAD circumstance. It generates new lobe profile and calculates automatically the flow rate and flow rate irregularity according to the lobe profile generated. Results obtained from the analysis enable the designer and manufacturer of oil pump to be more efficient in this field.

타원의 치형 형상을 갖는 로터 설계 자동화 시스템 개발 (Development of an Automated Design System for Oil Pumps with Ellipse Lobe Profile)

  • 정성윤;한승무;김철
    • 한국정밀공학회지
    • /
    • 제26권1호
    • /
    • pp.120-129
    • /
    • 2009
  • An internal lobe pump is suitable for oil hydraulics of machine tools, automotive engines, compressors, constructions and other various applications. In particular, the pump is an essential machine element of an automotive engine to feed lubricant oil. The subject of this paper is the theoretical analysis of internal lobe pump whose the main components are the rotors: usually the outer one is characterized by lobes with elliptical shape, while the inner rotor profile is determined as conjugate to the other. And the integrated system which is composed of three main modules has been developed through AutoLISP under AutoCAD circumstance. It generates new lobe profile and calculates automatically the flow rate and flow rate irregularity according to the lobe profile generated. Results obtained from the analysis enable the designer and manufacturer of oil pump to be more efficient in this field.

우측 폐상엽 기관지에 발생한 고립성 유두종: 1례 치험 및 문헌 고찰 (Solitary Papilloma of the Right Upper Lobe Bronchus: Report of a Case and Review of the Literature)

  • 배수동
    • Journal of Chest Surgery
    • /
    • 제5권2호
    • /
    • pp.135-140
    • /
    • 1972
  • Papilloma of the upper respiratory tract, particularly larynx and vocal cords are relatively common disease. However, solitary papilloma of the bronchus is extremely rare condition and only a handful cases were reported in the literature. The patient is a 39 year old housewife who has been suffering from productive cough and occasional hemoptysis in the past one year. X-ray of the chest showed complete atelectasis of the right upper lobe. Bronchography revealed a hemispherical protruding mass in the right main bronchus with complete occlusion of the upper lobe bronchus. Bronchoscopy showed a whitish friable mass in the lumen of the right main bronchus biopsy of which was reported as benign papilloma. Right upper lobectomy together with wedge resection of the portion of right main bronchus to include the tumor was done. Cut-edges of the bronchus were stitched together with interrupted fine dacron sutures. During this procedure, right main bronchus was gently clamped with non-crushing Satinsky type clamp. Patient has had uneventful recovery from surgery and was discharged without symptom. Patientis doing well three months following the operation.

  • PDF

삼각 격자구조를 갖는 평면배열 안테나의 부엽 레벨 감소를 위한 최적 평면배열 형상에 관한 연구 (STUDY ON THE OPTIMAL PLANAR ARRAY STRUCTURE WITH TRIANGULAR LATTICE FOR SIDE-LOBE REDUCTION)

  • 배지훈;성낙선;이태윤;김종면;표철식
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.250-254
    • /
    • 2002
  • In this paper, we design an optimized planar array structure with triangular lattice for side-lobe reduction using a genetic algorithm. A constraint optimization is implemented by optimally removing some outer array elements far from the array center. It is shown that only the proper array shape without optimizing the magnitudes and phases of each array antenna can give low side-lobe level with a slight main beam broadening.

  • PDF

페이즈드 어레이 트랜스듀서에 있어서 구성 압전소자의 간격 변화에 따른 초음파 빔 전파 특성 해석 (Analysis of the Ultrasonic Beam Profile Due to Variation of the Inter-Element Spacing for the Phased Array Transducer)

  • 최상우;이준현
    • 대한기계학회논문집A
    • /
    • 제24권4호
    • /
    • pp.972-981
    • /
    • 2000
  • The phased array transducer has two distinct advantages. One is rapid scanning comparing with the conventional mechanical or manual scanning system. Therefore, output image is represented in real-time. The other is the dynamic focusing and the dynamic steering of ultrasonic beam. Only the delay times that are controlled electrically are used to focus and to steer beam without any lenses or wedges. In this study, the profile of the ultrasonic beam for the phased array transducer has been simulated in the Huygens principle with varying the inter-element spacing of the linear phased array transducer. From the result of this study, it was found that the ultrasonic beam spread wider as the inter-element spacing was decreased. However, the focusing effect was improved, even when the number of the element was not big. In addition, there was grating lobes that are constructed when the inter-element spacing is more than half wavelength. However, this grating lobe has lower amplitude than the main lobe.

기관및 기관지 협착증 환자의 외과적 치료 (Surgical Management of Tracheal and Bronchial Stenosis)

  • 유정훈
    • Journal of Chest Surgery
    • /
    • 제25권11호
    • /
    • pp.1299-1304
    • /
    • 1992
  • We experienced 5 cases of tracheal stenosis and 7 cases bronchial stenosis treated surgically at the Department of Thoracic and Cardiovascular Surgery, School of Medicine, Hanyang University during 5 years. The causes of tracheal stenosis were prolonged endotracheal intubation 1 case, tracheostomy 1 case, the sequela of endobronchial tuberculosis 2 cases and tracheomalacia 1 case. The causes of bronchial stenosis were all endobronchial tuberculosis. The managements of tracheal stenosis were tracheal resection and end to end anastomosis. The resected lengths of trachea were 1.5cm, 3cm and 7.5cm. One case of suglottic stenosis was underwent the resection of trachea, 8cm in length, and the laryngotracheal anastomosis was done, but the re-stenosis of trachea was developed after 4 weeks post-operatively. One case of tracheomalacia was done permanent tracheostomy only, because the entire trachea was adhered to the surrounding tissue. The managements of bronchial stenosis were resection of involved lobe or one lung, in the 5 case. One case with Lt. main bronchial stenosis and atelectasis of Lt. upper lobe was done the lobectomy of Lt. upper lobe only and then, the Lt. pneumonectomy was done re-operatively because the atelectasis of Lt. lower lobe had continued. The other one case with stenosis of Rt. main bronchus, failed the insertion of metalic stent, was underwent the Rt. upper lobe lobectomy, sleeve resection and side to end anastomosis

  • PDF