• Title/Summary/Keyword: Main flow

Search Result 3,314, Processing Time 0.032 seconds

Computational Performance Prediction of Main Coolant Pump for the Integral Reactor SMART (일체형원자로 SMART 냉각재 순환펌프의 전산성능예측)

  • Kim M. H;Lee J. S;Park J. S;Kim J. I;Kim K. K
    • Journal of computational fluids engineering
    • /
    • v.8 no.3
    • /
    • pp.32-40
    • /
    • 2003
  • CFD analyses of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump including suction and discharge parts are presented and compared with experimental data. The purpose of the current study is to validate the CFD method for the performance analysis of the main coolant pump for SMART and to investigate the effect of suction and discharge shapes on the pump performance. To generate a performance curve, not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicts the experimental head value. In the range of the higher flow rates, the results are also in very good agreement with the experimental data, in magnitude but also in terms of slope of variation. For lower flow rates, the results shows that the analysis considering the suction and discharge well describe the typical S-shape performance curve of the axial pump.

A study on water quality change by land use change using HSPF

  • Kim, Tae Geun;Choi, Kyoung-sik
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.123-128
    • /
    • 2020
  • Non-point source pollutant load reductions were calculated using the Hydrologic Simulation Program-Fortran (HSPF) model under the assumption that landuse pattern was changed according to land purchases. Upon the simulation of non-point pollutant and areas with high land purchase ratios to select a buffer zone, the Namgang dam Reach 11, Imha dam Reach 10, and the Reach 136 watershed of the main river were found to rank high for the construction of buffer zones. Assuming that the forms of the purchased lands were changed to wetlands, biological oxygen demand (BOD) loads were changed through the HSPF model. No changes of BOD were present in the Namgang dam and the Imha dam watersheds. BOD loads in Reach 136 according to landuse change were analyzed through a flow duration analysis based on the total maximum daily loads of the United States. The flow duration analyses undertaken to examine changes in BOD of main river Reach 136 watershed indicated a shift of 0.64 kg/d from 3.16 to 2.52 during high flow. The change of BOD under the conditions of moist, mid-range and dry were 11.9%, 9% and 4.5%. At the low flow condition, the variation range in the BOD load was from 0.58 kg/d to 0.41 kg/d.

A Study on Method of Planning for a Residential Unit under Consideration of Local Climate - Focused on Wind Corridor - (지역기후기능을 고려한 주거단지계획기법에 관한 연구 - 바람길을 중심으로 -)

  • Kim, Dae-Wuk;Jung, Eung-Ho;Ryu, Ji-Won;Park, Ji-Hye
    • Journal of the Korean housing association
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2007
  • This research has been implemented based on the area of #369 Dowon-dong, Dalseo-gu, Dae-gu which is considered as a place with satisfactory characteristics for the flow of fresh air into the city. Simulations of the target area both prior to the development plan and after apartment complex blocking were analyzed in regard to blocking planning and pilotis based on the main direction of wind, $90^{\circ}$ (east wind) and $180^{\circ}$ (south wind). In addition, congested wind corridor flow in the target place was identified through a pollution spread simulation according to the wind corridor. Therefore, the flow of wind in the one area is affected by the blocking of the complex and the main direction of the wind. Also blocking, in regard of pilotis, provides a better flow of wind. This study was implemented based on wind formation by apartment complex planning, so further study on the other factors affecting the flow of a wind corridor along with block planning and pilotis need to be carried out. Sustainable environmental factors through analysis of the environmental factors have to be analyzed. Moreover, building and complementing fundamental resources and systematic devices should be supported.

Transient Response Analysis of a Control Valve for CO2 Refrigerant (CO2냉매용 제어밸브의 응답 특성)

  • Kim, Bo Hyun;Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.11-16
    • /
    • 2018
  • Pilot operated control valve for $CO_2$ refrigerant is a valve that can perform various functions according to the user's intention by replacing pilot units, widely used for flow rate, pressure, and temperature control of refrigeration and air conditioning systems. In addition, $CO_2$ refrigerant, that requires high pressure and low critical temperature, can be installed and used in all positions of the refrigeration system, regardless of high or low pressure. In this paper, response characteristics are modeled and analyzed based on behavior of the main piston of the pilot-operated control valve. Although various factors influence operation of the main piston, this paper analyzes the effect of equilibrium pressure depending on valve installation position and application, and inlet and outlet orifice size of the load pressure feedback chamber to determine feedback characteristics of the main piston. As a result, it was possible to quantitatively analyze the effect of change in equilibrium and load pressure feedback chamber flow path size on the change in main piston dynamic and static characteristics.

Flow Visualizations and Laser Doppler Velocity Measurements in a Fontan Connection

  • Kim, Young-H.;Yoganathan, Ajit P.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.111-114
    • /
    • 1994
  • Three component velocity measurements with a refractive index-matching technique was used to investigate the flow characteristics in the atrio-pulmomnary (AP) Fontan connection under the steady flow condition. A strong swirl was observed in the extra-cardiac conduit and the main pulmonary artery (MPA). Maximum velocity magnitude in the MPA was about 0.8 m/s near the posterior wall at 6 liter/min. Swirling motion of the flow as well as geometric abnormalities of the connection are important factors in energy loss across Fontan connections.

  • PDF

NUMERICAL ANALYSIS OF TUNNEL FLOW INDUCED BY JET FAN (제트팬 운전에 의해 형성되는 터널내 유동에 대한 수치적 해석)

  • Kim, J.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.10-13
    • /
    • 2010
  • The flow field in road tunnel is influenced by some facts such as piston effect of vehicle's move, operation of ventilation facilities, natural wind and buoyancy effect of fire plume. Among those, jet fan is one of main ventilation facilities especially in longitudinal ventilation system of tunnel. In this study to analyze tunnel flow induced by operation of jet fan, numerical simulation has been carried out. The velocity distributions and streamlines in tunnel are examined to consider the three-dimensional characteristics of tunnel flow caused by jet fan.

  • PDF

A Study on the Improvement of the Traffic Flow of The Main Channel in Kwangyang Port (광양항 주항로 교통 흐름의 개선에 관한 연구)

  • 정태권;임남균
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.3
    • /
    • pp.43-50
    • /
    • 1998
  • This study aims at estimating the in-and-out traffic volume and improving the main channel in Kwangyang Harbour, by utilizing measurement of congestion, i.e, the bumper model. In 2011, the traffic volume of the main channel is 11.96 ships per hour and its traffic density is evaluated 9.53% of the basic traffic capacity. Therefore the existing width of the main channel, 850m is safe enough but the channel requires the traffic separation scheme as suggested in order to secure the safe of the transit vessel.

  • PDF

Cause Analysis for the Wall Thinning and Leakage of a Small Bore Piping Downstream of an Orifice (주증기계통 오리피스 후단 소구경 배관의 감육 및 누설 발생)

  • Hwang, Kyeong Mo
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.227-232
    • /
    • 2013
  • A number of components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the components. In April 2013, one (1) inch small bore piping branched from the main steam line experienced leakage resulting from wall thinning in a 1,000 MWe Korean PWR nuclear power plant. During the normal operation, extracted steam from the main steam line goes to condenser through the small bore piping. The leak occurred in the downstream of an orifice. A control valve with vertical flow path was placed on in front of the orifice. This paper deals with UT (Ultrasonic Test) thickness data, SEM images, and numerical simulation results in order to analyze the extent of damage and the cause of leakage in the small bore piping. As a result, it is concluded that the main cause of the small bore pipe wall thinning is liquid droplet impingement erosion. Moreover, it is observed that the leak occurred at the reattachment point of the vortex flow in the downstream side of the orifice.

A Study on Numerical Analysis and Wall Thinning Effect in Accordance with the Eddy Current of MFIV Lower Body (주급수격리밸브 하부몸체의 와류현상에 따른 감육영향 및 수치해석 연구)

  • Hwang Kyeong-Mo;Jin Tae-Eun;Kim Kyung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.707-714
    • /
    • 2006
  • A numerical analysis study has performed in terms of fluid dynamics to identify the wall thinning generated in the main feedwater isolation valve body of a nuclear power plant. To review the relations between flow characteristics and the wall thinning induced by flow accelerated corrosion (FAC), numerical analysis using FLUENT code and ultrasonic tests (UT) were performed. The local velocities according to the analysis results were compared with the distribution of the measured wall thickness by ultrasonic tests. The comparison results show that the local velocity in the x-direction had no correlation with the wall thinning but the local velocity in the y-direction and turbulence intensity had a great influence on that. These results provide a good match to those of the previous studies - locations colliding vertically against components undergo severe wall thinning. These results may be utilized to the design modification and the wall thinning management for main feedwater isolation valves for preventing the wall thinning degradation.

Effect of Process Parameters on the Hardness and Wear Rate of Thermal Sprayed Ni-based Coatings (니켈기 경질 용사코팅의 경도 및 마모율에 미치는 공정조건의 영향)

  • Kim, K.T.;Kim, J.D.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.1
    • /
    • pp.51-56
    • /
    • 2011
  • The various process parameters of thermal spray process affects on quality of Ni-based coatings. Thus, there is need to analyze the effect of process parameters on quality of Ni-based coatings. In this paper, the effects of process parameters on hardness and wear rate of Ni-based coatings were investigated using 4 design of experiments. First, the Ni-based coatings were fabricated according to $L_9(3^4)$ orthogonal array. The hardness tests and the wear tests were performed on the Ni-based coatings. The analysis of variance for the hardness and wear rate were carried out. As a results, the acetylene gas flow and the powder feed rate were identified as main factors effected on the hardness and the oxygen gas flow and the acetylene gas flow were identified as main factors effected on the wear rate. The full factorial experiments design with different levels was applied for investigation of effect of these main factors.