• 제목/요약/키워드: Main conversion

검색결과 591건 처리시간 0.023초

8200호대 전기기관차 주변환장치 LCC 분석 (Life Cycle Cost Analysis of Main Conversion System in 8200 Series Electric Locomotive)

  • 김완일;이계승;최종록;김재문
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1830-1835
    • /
    • 2017
  • 8200 Series Electric Locomotives are mostly imported from overseas due to aging and uncertainty of source technology, and it's the maintenance cost is increasing. We are analyzed life cycle costs based on international standards such as IEC 60300-3-3 and IEC62278. The main conversion system of the 8200 series electric locomotive is closely related to vehicle operation and is one of the subsystems requiring frequent maintenance. In this paper, the life cycle cost of the main conversion unit in 8200 series electric locomotive is analyzed based on the maintenance manual. As a result of analysis, maintenance cost of GTO module and control device is relatively high, and it is confirmed that the cost increases according to the useful life.

8200호대 전기기관차 주변환장치 LCC 비교 분석 (Life Cycle Cost Comparative Analysis for Main Conversion System in 8200 Series Electric Locomotive)

  • 김완일;창윤우;김동만;김재문
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1717-1722
    • /
    • 2018
  • Parts and units of 8200 series electric locomotive are aging, but and source technology is not secured. As a results, maintenance costs are increasing steadily due to using expensive substitute parts. Therefore, various studies have been conducted to reduce maintenance costs. In this paper, the life cycle cost(LCC) of the developed and conventional products were compared and analyzed about main conversion system in 8200 Series electric locomotive. As a result of analysis, the material cost was the highest in the conventional product among the various item costs. On the other hand, it is confirmed that preventive cost was the highest among the costs about the developed product.

Zero-shot voice conversion with HuBERT

  • Hyelee Chung;Hosung Nam
    • 말소리와 음성과학
    • /
    • 제15권3호
    • /
    • pp.69-74
    • /
    • 2023
  • This study introduces an innovative model for zero-shot voice conversion that utilizes the capabilities of HuBERT. Zero-shot voice conversion models can transform the speech of one speaker to mimic that of another, even when the model has not been exposed to the target speaker's voice during the training phase. Comprising five main components (HuBERT, feature encoder, flow, speaker encoder, and vocoder), the model offers remarkable performance across a range of scenarios. Notably, it excels in the challenging unseen-to-unseen voice-conversion tasks. The effectiveness of the model was assessed based on the mean opinion scores and similarity scores, reflecting high voice quality and similarity to the target speakers. This model demonstrates considerable promise for a range of real-world applications demanding high-quality voice conversion. This study sets a precedent in the exploration of HuBERT-based models for voice conversion, and presents new directions for future research in this domain. Despite its complexities, the robust performance of this model underscores the viability of HuBERT in advancing voice conversion technology, making it a significant contributor to the field.

크롬 프리 세륨 용액에 의한 AZ31 마그네슘 합금의 화성 피막에 대한 특성 평가 (Characteristics of Conversion Coating of AZ31 Magnesium Alloy Formed in Chromium-Free Cerium-Based Solution)

  • 김명환;이동욱;곽삼탁;문명준
    • 한국표면공학회지
    • /
    • 제49권1호
    • /
    • pp.62-68
    • /
    • 2016
  • A chromium-free Ce-based conversion coating formed by immersion in a solution containing cerium chloride and nitric acid on AZ31 magnesium alloy has been studied. The effects of acid pickling on the morphology and the corrosion resistance of the cerium conversion coating were investigated. The corrosion resistance of the conversion coating prepared on AZ31 Mg alloy after organic acid pickling was better than that of inorganic acid pickling. The morphology of the conversion-coated layer was observed using optical microscope and SEM. Results show that the conversion coatings are relatively uniform and continuous, with thickness 1.0 to $1.1{\mu}m$. The main elements of the conversion coating of AZ31 Mg alloy are Mg, O, Al, Ce and Zn by EDS analysis. The electrochemical polarization results showed that the Ce-based conversion coating could reduce the corrosion activity of the AZ31 Mg alloy substrates in the presence of chloride ions.

2단계 고정화 효소반응기를 활용한 Cyclodextrin의 연속생산 (Continuous Production of Cyclodextrin in Two-Stage Immobilized Enzyme Reactor Coupled with Ultrafiltration Recycle System)

  • 이용현;이상호;한일근
    • 한국미생물·생명공학회지
    • /
    • 제19권2호
    • /
    • pp.171-178
    • /
    • 1991
  • The two-stage enzyme reactor, packed with cyclodextrin glucanotransferase (CGTase) immobilized on Amberite IRA 900, coupled with ultrafiltration membrane was investigated for continuous production of cyclodextrin (CD). 5% (w/v) of soluble starch was partially cyclized, in the 0.1 l first-stage immobilized enzyme reactor, up to CD conversion yield of 10% (w/w) at retention time of 0.56hr and 1.5 units of immobilized CGTase/1g of carrier. In the second stage main immobilized enzyme reactor capacity of 1.5 l, the maximum CD conversion yield of 39% (w/v) was achieved at retention time of 2.8hr and 0.47 unit of CGTase/1 g of carrier. Unreacted residual dextrin was fractionated with ultrafiltration membrane, and then, recycled into the second-stage main bioreactor to increase the CD conversion yield. The most suitable membrane size and the volume concentration ratio (concentrate: filterate) for recycling of unreacted residual dextrin were found to be 5K dalton and 4:6, respectively. CD conversion yield was increased about 3~4% upon co-immobilization of pulluanase along with CGTase. Spent Amberite IRA 900 can be reutilized consecutively more than 3 times for immobilization of CGTase after regeneration.

  • PDF

전자파 플라즈마 토치를 이용한 이산화탄소와 메탄의 Syngas 합성 (Conversion of $CO_2$ and $CH_4$ to Syngas by Making Use of Microwave Plasma Torch)

  • Dong Hun, Shin;Yong Cheol, Hong;Han Sup, Uhm
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2004년도 추계 학술발표회 논문집
    • /
    • pp.195-200
    • /
    • 2004
  • Carbon dioxide ($CO_2$) and methane (CH$_4$) are two major greenhouse Bases. $CO_2$is a stack gas of many industrial processes and the main product of the hydrocarbon combustion. There is recent research interest on the synthesis gas (syngas) formation from $CO_2$ and CH$_4$, via the following reaction: CH$_4$+$CO_2$longrightarrow 2H$_2$+$CO_2$, in order to reduce the greenhouse effects and to synthesize various chemicals, Preliminary experiments were conducted on the conversion of $CO_2$ and CH$_4$ to syngas by making use of a microwave plasma torch at atmospheric pressure. Conversion rates of $CO_2$and CH$_4$ to hydrogen (H$_2$), carbon monoxide (CO) and higher hydrocarbons were investigated using Gas Chromatography (GC) and Fourier Transform Infrared (FTIR). The experimental data indicate that the main products were H$_2$, CO and small amount of higher hydrocarbons, such as ethylene (C$_2$H$_4$).

  • PDF

마그네슘-알루미늄 합금의 화성처리 공정 개발과 그 내식성 평가 (Development of chemical conversion coating process for Mg-Al alloy and its anti-corrosion property)

  • 김성종
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.265-266
    • /
    • 2006
  • The chemical conversion coating formed on magnesium alloy investigated for low cost and harmless in environment by using the colloidal silica as the main component. The film formed in 298 K is thick, the film, which was thought combination of Si-O, was formed. The film formed in 313 K is thinner than that in 298 K. The quantity of film formed at high temperature such as 333 K and 353 K is smaller than dissolved quantity. At the anodic polarization experiment, corrosion resistance in sealing by hot water after chemical conversion treatment in basic solution condition get worse than that in comparison with basic solution condition. In salt spray test, the ratio of black rust on specimen that did not conducted chemical conversion treatment was five times or more compared with those of chemical conversion treated specimen. The film thickness of chemical conversion coating produced by alkali treatment process is thinner than in comparison with that of specimen produced in basic chemical conversion treatment solution condition. It is thought, however, that it showed good corrosion resistance during salt spray test because the area of microcracks is small.

  • PDF

지식전환선호도와 직무특성이 직무유효성에 미치는 영향 (The Effect of Fit between Knowledge Conversion Preference and Job Character on Job Effectiveness)

  • 하갑진;성정현
    • 경영과정보연구
    • /
    • 제17권
    • /
    • pp.161-189
    • /
    • 2005
  • As the importance of intellectual assets has been brought into relief, this study aims at positively verifying where the intellectual workers' overall level of their knowledge conversion preference and their job character has reached, and how much the knowledge conversion preference, the job character and the fitness of both factors affects the job effectiveness respectively. For this purpose 3 types of research hypotheses were set up and the result of the verification of the hypotheses is summarized as follows: First, the verification of the relation between the knowledge conversion preference and the job effectiveness revealed that the workers who have the higher synthetic ability in knowledge conversion preference show the higher job satisfaction and job product. Secondly, the verification of the relation between the MPS representing the job character by measured index and the job satisfaction revealed that the absolute value of relative coefficient between the 4 factors excluding the public welfare factor and the MPS is 4, interpreted as medium correlation. Thirdly, the analysis on the degree of relation between the job product measured by the quality of job result and the input effort and the MPS showed that the absolute value of person relative coefficient is 5, interpreted not only as medium correlation but also very meaningful. Accordingly, the main purpose of this study was to give a guideline which can be utilized as an indicator for educating, training and placing the workers. As results, the main effect that the variable of knowledge conversion preference and job character chosen as the independent variable influences on the dependent variable of job satisfaction and job product is very meaningful except the public welfare factor.

  • PDF

용도전환 시설의 계획 특성에 관한 연구 - 일본 동경 G-오피스 빌딩의 사례를 중심으로 - (An Analysis on Design Strategies for Building Conversion - Case Study on the G-Office Building in Japan -)

  • 이승미;강인호
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.290-294
    • /
    • 2008
  • Conversion of the building can be a core strategy to activate the urban regeneration. Especially in the decayed district, the conversion or retrofit of old building can be a core catalyst to stimulate the urban regeneration. Throughout the case study, a conversion from office to dwelling, there were figured out the design strategies to respond to spatial, functional requirements. The results are as follows ; 1) The main design strategy is to articulate the space by embedding the wall, mass in the rectangular space. 2) to respond to the small size of space, the flexible, movable wall system Is adopted. This gives the selectiveness to the use of space. 3) to secure the livability of interior space, the buffer zone, a terrace space, is fully utilized. This space acts as thermal buffer zone as well as a semi-interior space.

  • PDF

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.