• 제목/요약/키워드: Main Steam Pipe

검색결과 42건 처리시간 0.021초

Methods and Systems for High-temperature Strain Measurement of the Main Steam Pipe of a Boiler of a Power Plant While in Service

  • Guang, Chen;Qibo, Feng;Keqin, Ding
    • Journal of the Optical Society of Korea
    • /
    • 제20권6호
    • /
    • pp.770-777
    • /
    • 2016
  • It has been a challenge for researchers to accurately measure high temperature creep strain online without damaging the mechanical properties of the pipe surface. To this end, a noncontact method for measuring high temperature strain of a main steam pipe based on digital image correlation was proposed, and a system for monitoring of high temperature strain was designed and developed. Wavelet thresholding was used for denoising measurement data. The sub-pixel displacement search algorithm with curved surface fitting was improved to increase measurement accuracy. A field test was carried out to investigate the designed monitoring system of high temperature strain. The measuring error was less than $0.4ppm/^{\circ}C$, which meets actual measurement requirements for engineering. Our findings provide a new way to monitor creep damage of the main steam pipe of a boiler of an ultra-supercritical power plant in service.

장기사용된 1Cr-0.5Mo 주증기관의 수명평가 (Life Evaluation of Long-time Used 1Cr-0.5Mo Main Steam Pipe)

  • 백수곤;홍성인
    • Journal of Welding and Joining
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 1998
  • Most fossil power plants and many critical components will be approaching the end of their nominal design life. At the same time, utilities are finding it economically attractive to extend the use of these plants for several more years, Especially Main steam pipe that operated under high temperature and pressure, often under the more severe operating conditions associated with cycling duty, is most important pipe system and critical component in fossil power plant. To extend the viability of older pipe system and to improve the operation and maintenance reliability, some technologies of precise diagnosis and life management have evolved out of the necessity. The purpose of this study is to descrive the related technologies and show the example of one power plants. The purpose of this study is to descrive the related technologies and show the example of one power plants. The stress analysis was done using ANSYS FEM Code. The branch area from main steam to turbine was the high stressed zone. To evaluate the degradation of the pipe material, replica, visual check, magnetic test, hardness test were done at the welding spot. The degradation level of welding point was E/F, so the remaining life of the welded area was about 0-25%.

  • PDF

고에너지배관 파단위치에 따른 배관휩과 충격파의 영향 평가 (Evaluation of Blast Wave and Pipe Whip Effects According to High Energy Line Break Locations)

  • 김승현;장윤석;최청열;김원태
    • 한국압력기기공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.54-60
    • /
    • 2017
  • When a sudden rupture occurs in high energy lines, ejection of inner fluid with high temperature and pressure causes blast wave as well as thrust forces on the ruptured pipe itself. The present study is to examine pipe whip behaviors and blast wave phenomena under postulated pipe break conditions. In this context, typical numerical models were generated by taking a MSL (Main Steam Line) piping, a steam generator and containment building. Subsequently, numerical analyses were carried out by changing break locations; one is pipe whip analyses to assess displacements and stresses of the broken pipe due to the thrust force. The other is blast wave analyses to evaluate the broken pipe due to the blast wave by considering the pipe whip. As a result, the stress value of the steam generator increased by about 7~21% and von Mises stress of steam generator outlet nozzle exceeded the yield strength of the material. In the displacement results, rapid movement of pipe occurred at 0.1 sec due to the blast wave, and the maximum displacement increased by about 2~9%.

원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구 (A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants)

  • 이승표;김진회
    • 한국압력기기공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

한울 3호기 주급수 배관 용접부 육안검사 경험 (Experience in Visual Testing of the Main Feed Water Piping Weld for Hanul Unit 3)

  • 윤병식;문균영;김용식
    • 한국압력기기공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.74-78
    • /
    • 2015
  • Nuclear power plant steam generator that is one of the main component has several thousands of thin tubes. And the steam generator tube is subject to damage because of the severe operation conditions such as the high temperature and pressure. Therefore periodic inspections are conducted to ensure the integrity of steam generator component. Hanul unit 3 also has been inspected in accordance with in-service inspection program and is scheduled to be replaced for exceeding the plugging rate which was recommended by manufacturer. During the steam generator replacement activity, we found several clustered porosity on inner surface of main feed water pipe. Additionally crack-like indications were found at weld interface between base material and weld of main feed water pipe. This paper describes the field experience and visual testing results for inner surface of main feed water pipes. The destructive test result had shown that these indications were porosities which were caused by manufacturing process not by operation service.

수격 현상에 근거한 대형 주증기관의 구조건전성 평가 (Structural Integrity Evaluation of Large Main Steam Piping by Water Hammering)

  • 조종현;이영신;김연환;김해란
    • 대한기계학회논문집A
    • /
    • 제36권9호
    • /
    • pp.1103-1108
    • /
    • 2012
  • 주증기관은 보일러와 터빈을 연결하는 주요계통이다. 운전조건으로 인한 배관시스템에 손상을 제한 할 수 있기 때문에 수격현상 해석은 중요하다. 배관시스템의 불안정한 유동에 의해 생성되는 수격현상은 압력의 과도한 변화, 진동 및 소음을 일으킬 수 있다. 주증기관 구조는 운전환경아래 압력맥동 및 여러 진동 등을 안전하게 견딜 수 있도록 설계되어야 한다. 본 논문에서는 정지 및 정상 운전기간 동안 배관에 유입되는 수격현상을 과도조건에 적용하여 ASME 피로수명 방법론과 유한요소해석에 따라 주증기관의 구조건전성을 평가하였다. 계산된 교번응력 및 피로응력 평가 결과, ASME 피로수명의 허용요건을 만족하였다.

가압경수로 주증기관 파단시 증기발생기 2차측 과도 열수력 응답에 미치는 오리피스형 유량제한기의 영향 (EFFECTS OF AN ORIFICE-TYPE FLOW RESTRICTOR ON THE TRANSIENT THERMAL-HYDRAULIC RESPONSE OF THE SECONDARY SIDE OF A PWR STEAM GENERATOR TO A MAIN STEAM LINE BREAK)

  • 조종철;민복기
    • 한국전산유체공학회지
    • /
    • 제20권3호
    • /
    • pp.87-93
    • /
    • 2015
  • In this study, a numerical analysis was performed to simulate the thermal-hydraulic response of the secondary side of a steam generator(SG) model equipped with an orifice-type SG outlet flow restrictor to a main steam line break(MSLB) at a pressurized water reactor(PWR) plant. The SG analysis model includes the SG upper steam space and the part of the main steam pipe between the SG outlet and the broken pipe end. By comparing the numerical calculation results for the present SG model to those obtained for a simple SG model having no flow restrictor, the effects of the flow restrictor on the thermal-hydraulic response of SG to the MSLB were investigated.

주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책 (Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header)

  • 김연환;배용채;이영신
    • 한국소음진동공학회논문집
    • /
    • 제15권8호
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.

주증기 배관 헤더의 맥동이 분기 배관에 미치는 영향 (Vibration Effect for Branch Pipe System due to Main Steam Header Pulsation)

  • 김연환;배용채;이현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.780-785
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of a nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve or heather generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 7nn nuclear power plant. The exciting sources and response or the piping system are investigated by using on site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3Hz, 4.4Hz and 6.6Hz transferred from main steam header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness were installed to reduce excessive vibration.

  • PDF

화력발전소 주증기배관에서 밸브 차단에 따른 수증기 충격 특성에 관한 연구 (A Study on the Steam Hammering Characteristics by Sudden Closure of Main Stop Valve in the Main Steam Piping System of a Power Plant)

  • 하지수;이부윤
    • 한국가스학회지
    • /
    • 제17권2호
    • /
    • pp.70-77
    • /
    • 2013
  • 본 연구는 화력발전소 최종과열기에서 고압터빈 사이 배관과 고압터빈을 지난 곳에 있는 체크밸브와 1차 재열기 사이 배관을 포함한 수증기 배관시스템에서 터빈의 급작스런 사고로 인해 터빈으로 들어가는 수증기를 차단할 때 발생하는 수증기 충격이 배관시스템에 미치는 영향을 분석하는 연구이다. 이를 위해서 수격현상 해석에 많이 사용하는 Flowmaster 소프트웨어로 배관시스템을 모델링하고 시간 변화에 따라 배관 내부의 압력, 질량유량률의 특성을 파악하였다. 이러한 특성으로부터 수증기 충격이 주로 영향을 미치는 곡관에서 수증기 충격에 의한 힘을 도출하였다. 본 연구를 통해서 수증기 충격은 주증기 차단 밸브 직전의 곡관과 체크밸브 이후에 바이패스 배관과 연결되는 곡관에서 수증기 충격에 의한 힘이 가장 크게 나타남을 밝혀냈다. 본 연구에서는 이렇게 도출한 힘의 기본 자료를 이용하여 차후 연구에서 화력발전소 수증기 배관시스템의 수증기 충격 시 곡관과 지지대의 안전성을 진단하는 토대를 구축하였다.