• Title/Summary/Keyword: Main Axis

Search Result 537, Processing Time 0.034 seconds

Pitch Measurement of One-dimensional Gratings Using a Metrological Atomic Force Microscope and Uncertainty Evaluation (미터 소급성을 갖는 원자간력 현미경을 이용한 1차원 격자 피치 측정과 불확도 평가)

  • Kim Jong-Ahn;Kim Jae Wan;Park Byong Chon;Eom Tae Bong;Kang Chu-Shik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.84-91
    • /
    • 2005
  • We measured the pitch of one-dimensional (ID) grating specimens using a metrological atomic force microscope (M-AFM). The ID grating specimens a.e often used as a magnification standard in nano-metrology, such as scanning probe microscopy (SPM) and scanning electron microscopy (SEM). Thus, we need to certify the pitch of grating specimens fur the meter-traceability in nano-metrology. To this end, an M-AFM was setup at KRISS. The M-AFM consists of a commercial AFM head module, a two-axis flexure hinge type nanoscanner with built-in capacitive sensors, and a two-axis heterodyne interferometer to establish the meter-traceability directly. Two kinds of ID grating specimens, each with the nominal pitch of 288 nm and 700 nm, were measured. The uncertainty in pitch measurement was evaluated according to Guide to the Expression of Uncertainty in Measurement. The pitch was calculated from 9 line scan profiles obtained at different positions with 100 ㎛ scan range. The expanded uncertainties (k = 2) in pitch measurement were 0.10 nm and 0.30 nm for the specimens with the nominal pitch of 288 nm and 700 nm. The measured pitch values were compared with those obtained using an optical diffractometer, and agreed within the range of the expanded uncertainty of pitch measurement. We also discussed the effect of averaging in the measurement of mean pitch using M-AFM and main components of uncertainty.

STABILIZATION OF REFERENCE SIGNAL TRANSMISSION SYSTEM IN RADIO TELESCOPE FOR VLBI (VLBI 전파망원경 기준 신호 전송시스템 안정화)

  • Je, Do-Heung;Lee, Won-Kyu;Kim, Soo-Yeon;Chung, Moon-Hee;Song, Min-Kyu;Jung, Taehyun;Byun, Do-Young;Kim, Seung-Rae;Sohn, Bong-Won;Wi, Seog-Oh;Han, Seog-Tae;Kang, Yong-Woo
    • Publications of The Korean Astronomical Society
    • /
    • v.28 no.3
    • /
    • pp.95-100
    • /
    • 2013
  • A fiber-optic reference signal transmission system, which transmits the 1.4 GHz reference signal from H-maser to receiver cabin in radio telescopes, was adopted for compensating the phase changes due to temperature variation and antenna movement. At the first experiment, the remote signal's phase changed more than 15 degrees at 1.4 GHz. We found unstable components in sub-system experiments and replaced them. The main cause of unstable phase stability was the unaligned polarization axis between Laser Diode and Mach-Zehnder Modulator (MZM). The improved system stability showed $1{\times}10^{-16}$ allan standard deviation at 1,000 sec integration time with the antenna fixed. When the antenna moves in the azimuth axis, the 1.4 GHz remote signal showed the phase change smaller than 0.2 degrees.

Applying of Indicators for Landscape Planning in Building Lots Development District around Urban Fringe (도시근교 택지개발지역의 경관계획지표 적용방안)

  • Kim, Yong-Soo;Park, Chan-Yong
    • Journal of Korean Society of Rural Planning
    • /
    • v.13 no.3
    • /
    • pp.51-60
    • /
    • 2007
  • In terms of the indicators by the type for the landscape plan per the district nit, geographic ecology indicators were the items such as water, water system, topography and climate, while biological ecology indicators were the items such as green zone size, green zone ratio, biotope size and distribution. The sensory and visual indicators were the items such as view point, view axis and skyline, and the accessibility indicator items for the green zone were applied as the socially used indicators. As for the application method according to each indicator, the water or water system was expressed and applied through the slopes and elevation topographic analysis drawings, the climate was expressed and applied through the main direction of the wind and the cold wind pass alley drawings. As for the green zone size and green zone ratio, the land use according to the status and housing area development was compared to present the measured figures. In case of the biotop size and the distribution item, the range was limited to the preparation of the biotope drawings for the focused preservation. As for the view point and view axis, the view point was selected according to the view point to prepare and apply the view analysis drawing in which the view area to be preserved is analyzed. As for the skyline, its landscape photo was composed with the housing area shape, and then skyline photography was applied as the plan in order to propose and consider the various shapes of the skyline. As for the accessibility to the peen zone, the network drawing was drawn to reflect the users' accessibility and continuity of the green zone formed and preserved according to the land use plan and then the drawing was prepared and proposed as the applicable plan.

A study on the solution suggesting and the problem investigating of spatial designing through the axis of circulation in the extension of general hospital - A case study : medical college's hospital of Hanyang University - (종합병원의 증축과정에서 동선 중심축 형성을 통한 공간디자인의 문제점 도출과 해결안 제시에 관한 연구 -한양대학교 의과대학 부속병원의 사례-)

  • Kim, Kyu Sung;Lee, Jung Man
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2003
  • Contemporary hospital has more and more extension because the growth and change of hospital has to respond the various needs. For expanding, the sky bridge(sky walk) becomes one of the method to interconnect two or more buildings on the air. Sometimes the designers don't know exactly how the sky bridge works after construction. Beyond the role of interconnecting two buildings, the role of sky bridge is transformed the main axis of pedestrian in the whole hospital organization. This scope of analysis is about the sky bridge of Hanyang University hospital. The first method is the investigation of the utilization in this time. The second is the analysis of design drawings got form the designing of the past(1994-1998). From this analysis, the conclusions are followings.;The designer who wants to apply the sky bridge should more consider about, 1) how the sky bridge impacts the whole spatial system such as the pedestrian, patients, physicians, service's facilities etc. 2) what the inside of sky bridge has something such as natural light, ventilation, and the height, depth, width of aisle, the sign for seeking orientation. etc. In future the research relating sky bridge should be studied some hospital as well as one hospital for comparing the characteristics of the concepts and organizations

  • PDF

Optimum Washing Conditions of Artificially Soiled Cloths in a Drum-Type Washing Machine (드럼세탁기의 세척성 향상을 위한 인공 오염포의 세탁조건에 따른 세척성)

  • Chung, Hae-Won;Kim, Mi-Kyung;Kim, Hyun-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.11 s.158
    • /
    • pp.1589-1597
    • /
    • 2006
  • Nowadays, Korean consumers prefer drum-type washing machines to pulsator-type washers. Washing is a complex process involving the interaction of numerous physical and chemical influences. The main factors in the washing operations are the washing chemistry of the detergent along with the mechanical input, the wash temperature, and the time provided by the washing machine. Heavy-duty detergents that are used in drum-type washing machines contain different components from those used in vertical-axis washing machines. The bath ratio and the mechanical actions to which laundry is subjected are different between the drum-type and the vertical-axis washing machines. In this study we examined the effects of wash temperature, wash time, detergent concentration, and revolution speed on the removal of soils from artificially soiled cloths in a drum-type washing machine with heavy-duty commercial detergent. We used multiple regression analyses to find the relative importance of the factors and the optimum washing conditions. The results of these experiments showed that the washing temperature was the most important factor in the effective removal of most soils. This was followed by the washing time, the detergent concentration, and finally the revolution speed. In this study it was found that superfluous amounts of detergent did not sufficiently increase the soil removal rate. Koreans who are used to washing with cold water should increase the wash time to launder more efficiently.

CFD Analysis on the Flow Characteristics of Ejector According to the Position Changes of Driving Nozzle for F.W.G (수치해석을 이용한 담수장치용 이젝터의 노즐위치 변화에 따른 이젝터 유동특성 연구)

  • Joo, Hong-Jin;Jung, Il-Young;Yun, Sang-Kook;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.23-28
    • /
    • 2011
  • In this study, the ejector design was modeled using Fluent 6.3 of FVM(Finite Volume Method) CFD(Computational Fluid Dynamics) techniques to resolve the flow dynamics in the ejector. A vacuum system with the ejector has been widely used because of its simple construction and easy maintenance. Ejector is the main part of the desalination system, of which designs determine the efficiency of system. The effects of the ejector was investigated geometry and the operating conditions in the hydraulic characteristics. The ejector consists mainly of a nozzle, suction chamber, mixing tube (throat), diffuser and draft tube. Liquid is supplied to the ejector nozzle, the fast liquid jet produced by the nozzle entrains and the non condensable gas was sucked into the mixing tube. The multiphase CFD modeling was carried out to determine the hydrodynamic characteristics of seawater-air ejector. Condition of the simulation was varied in entrance mass flow rate (1kg/s, 1.5kg/s, 2kg/s, 2.5kg/s, 3kg/s), and position of driving nozzle was located from the central axis of the suction at -10mm, 0mm, 10mm, 20mm, 30mm.. Asaresult, suction flow velocity has the highest value in central axis of the suction.

Design of Broadband Spiral Antenna for Non-Linear Junction Detector (비선형 소자 탐지용 광대역 스파이럴 안테나의 설계)

  • Kim, Tae-Geun;Min, Kyeong-Sik;Lee, Kwang-Kun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.81-88
    • /
    • 2011
  • This paper presents a design of spiral antenna with broad bandwidth for non-linear junction detector(NLJD). An elliptical patch as radiating element located on center position of radiating surface, as well as the spiral elements on radiating surface was designed for broad bandwidth of spiral antenna. An antenna ground structure generating the multi resonance by spiral slit inserted on ground surface was also proposed. In order to realize high directivity and high gain of the proposed antenna, the cavity wall made of Fr4-epoxy and the metal cap were considered in design. As a result, the calculated gain of antenna with metal cap was improved about 3 dB with comparison of antenna without metal cap and the measured main beam directivity toward -z axis direction agreed well with calculation result. The measured axial ratio satisfied the circular polarization within -z axis ${\pm}45^{\circ}$ at design frequency bands and showed reasonable agreement with prediction.

Development of Fault Diagnosis Technology Based on Spectrum Analysis of Acceleration Signal for Paper Cup Forming Machine (가속도 신호의 주파수 분석에 기반한 종이용기 성형기 구동축 고장진단 요소기술 개발)

  • Jang, Jaeho;Ha, Changkeun;Chu, Baeksuk;Park, Junyoung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • As demand for paper cups markedly increases, this has brought about a requirement to develop fast paper cup forming machines. However, the fast manufacturing speed of these machines causes faults to occur more frequently in the final product. To reduce the possibility of producing faulty products, it is necessary to develop technologies to monitor the manufacturing process and diagnose the machine status. In this research, we selected the main driving axis of the forming machine for fault diagnosis. We searched the states of rotational elements related to the driving axis and suggested a fault diagnostic system based on spectrum analysis consisting of a real-time data acquisition device, accelerometers, and a diagnosis algorithm. To evaluate the developed fault diagnostic system, we performed experiments using a test station which resembles the actual paper cup forming machine. As a result, we were able to confirm that the proposed system was sufficiently feasible to diagnose any abnormalities in the operation of the paper cup forming machine.

Development of a Web-Based Program for Cross-Calibration and Record Management of Radiation Measuring Equipment

  • Park, So Hyun;Lee, Rena;Kim, Kyubo;Ahn, Sohyun;Lim, Sangwook;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.30 no.2
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose: To manage radiation measurement equipment, a web-based management program has been developed in this study. Materials and Methods: This program is based on a web service and Java Server Pages (JSP) and employs compatibility and accessibility. Results: The first step in the workflow has been designed to create accounts for each user or organization and to log in. The program consists of two parts: fields for listed instruments, and measurement information. The instruments for measuring radiation listed in this program are as follows: ionization chambers, survey meters, thermometers, barometers, electrometers, and phantoms. Instrument properties can be put in the recording fields and browsing for associated instruments can be performed. The main part of the program is the cross-calibration for each ion chamber. For instance, the ionization chamber to be used as a relative dosimeter can be registered by cross-calibration data with a reference chamber calibrated by an accredited laboratory. This program supports methods using the central axis transfer theory for cross-calibration for the ionization chambers. The reference and field ionization chambers were placed in a solid water phantom along the beam central axis at two different depths, and then the positions were switched. Each measured value was used for calculating the cross-calibration factor. Conclusions: Because many instruments are used and managed in radiation oncology departments, systematic, traceable recording is very important. The web-based program developed in this study is expected to be used effectively in the maintenance of radiation measurement instruments.

Sexual Maturity and Early Life History of the Mudskipper Scartelaos gigas (Pisces, Gobiidae): Implications for Conservation

  • Kim, Jin-Koo;Baek, Hea-Ja;Kim, Jae-Won;Chang, Dae-Soo;Kim, Joo-Il
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.403-410
    • /
    • 2011
  • Scartelaos gigas is an amphibious mudskipper species that inhabits mud flats in Korea, China, and Taiwan. This fish is at risk of extinction because of its very restricted habitat and overexploitation. Information about this fish's reproductive characteristics is needed for species conservation. The sexual maturity and early life history of S. gigas were investigated through histological methods and direct observation of eggs in the wild, respectively. In total, 560 individuals of S. gigas were collected with the aid of fishermen from March 2003 to October 2003 at Jung-do Island, southwest Korea. Through microscopic observations of gonadal development, it was determined that S. gigas of both sexes were immature in April, but began to reach maturity in May, and were then fully mature by June, which was maintained until July. In August, some female fish developed early oocytes, but by September oocytes were observed to have degenerated and had been absorbed. Spawned eggs were elliptical and had an average size of 1.37 mm (long axis) by 0.69 mm (short axis). The newly hatched larvae (3.03 mm total length, TL) had an open mouth and anus, two melanophores near the anus, and one large melanophore between the 18th and 19th myomeres. The larvae (3.18 mm TL) showed absorption of the yolk and oil globule within 5 days after hatching and became prelarvae. This species should be considered vulnerable or conservation-dependent, and thus parental fish need to be protected from fishermen during the main spawning season (June).