• Title/Summary/Keyword: Magnifier

Search Result 37, Processing Time 0.027 seconds

CHANGES IN ROOT CANAL CONFIGURATION USING DIFFERENT FILE TYPES AND TECHNIQUES (근관형성 기구 및 방법에 따른 근관 형태의 변화)

  • Huh, Young-Ju;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.291-304
    • /
    • 1997
  • The purposes of this study were to evaluate the changes in root canal configuration with canal instrumentation using different file types and techniques and to investigate most appropriate instrumentation technique in maintaining the original canal configuration with different file types. Fifty curved mesiobuccal or distobuccal canals of extracted human maxillary molar teeth were instrumented using a step-back technique with stainless steel K-files or nickel-titanium K-files, a crown-down pressureless technique with stainless steel K-files or nickel-titanium K-files and nickel-titanium engine-driven files. Radiographs were taken before and after instrumentation using a specially designed device that allowed for the pre-and postinstrumentation canals to be taken with the same X-ray angulation. Magnified X-ray images on a magnifier screen were traced and post instrumentation canal images were compared with the preinstrumentation ones. Changes in canal curvature and the incidence of procedural accidents were analyzed. The results were as follows : Crown-down pressureless technique with nickel-titanium K-files and nickel-titanium engine-driven filing produced no significant changes in canal curvature (p>0.05), while the step-back technique with stainless steel K-files or nickel-titanium K-files (p<0.01) and the crown-down pressureless technique with stainless steel K-files (p<0.05) produced significant changes. With nickel-titanium K-file, crown-down pressureless technique produced significantly less changes in canal curvature than step-back technique (p<0.05), while there was no significant difference between techniques with stainless steel K-files (p>0.05). File types exerted no significant influences in the changes of canal curvature both in the step-back technique and crown-down pressureless technique (0>0.05). Regardless of the file types used, step-back technique produced more procedural accidents such as ledge or elbow formation, apical zipping and apical transportation than the crowndown pressureless technique and nickel-titanium engine-driven filing. Both with stainless steel K-files and with nickel-titanium K-files, the incidence of apical extrusion of canal debris was higher in step-back technique than in crown-down pressureless technique.

  • PDF

Development Status of the DOTIFS: a new multi-IFU optical spectrograph for the 3.6m Devasthal Optical Telescope

  • Chung, Haeun;Ramaprakash, A.N.;Omar, Amitesh;Ravindranath, Swara;Chattopadhyay, Sabyasachi;Rajarshi, Chaitanya V.;Khodade, Pravin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.51.1-51.1
    • /
    • 2014
  • DOTIFS is a new multi-object Integral Field Spectrograph (IFS) being designed and fabricated by the Inter-University Center for Astronomy and Astrophysics, Pune, India, (IUCAA) for the Cassegrain side port of the 3.6m Devasthal Optical Telescope (DOT). The telescope is constructed by the Aryabhatta Research Institute of Observational Sciences, Nainital (ARIES). Its main scientific objectives are the physics and kinematics of the ionized gas, star formation and H II regions in nearby galaxies. It is a novel instrument in terms of multi-IFU, built in deployment system, and high throughput. It consists of one magnifier, 16 integral field units (IFUs), and 8 spectrographs. Each IFU is comprised of a microlens array and 144 optical fibers, and has $7.4^{\prime\prime}{\times}8.7^{\prime\prime}$ field of view with 144 spaxel elements with a sampling of 0.8" hexagonal aperture. The IFUs can be deployed on the telescope side port over an 8' diameter focal plane by x-y actuators. 8 Identical, all refractive, dedicated fiber spectrographs will produce 2,304 R~1800 spectra over 370-740nm wavelength range with single exposure. Currently, conceptual and baseline design review had been done, and is in the critical design phase with a review planned for later this year. Some of the components have already arrived. The instrument will see its first light in 2015.

  • PDF

Comparative study on the external micro-morphology of 3 kinds of minute pollen and spore Herbs (Pini Pollen, Typhae Pollen, Lygodii Spora) utilizing scanning electron microscope (주사전자현미경을 이용한 3종 화분포자류(花粉胞子類) 한약재(송화분(松花粉), 포황(蒲黃), 해금사(海金沙))의 미세형태 비교연구)

  • Kim, Young-Sik;Song, Jun-Ho;Choi, Goya;Lee, Guemsan;Ju, Young-Sung
    • The Korea Journal of Herbology
    • /
    • v.35 no.1
    • /
    • pp.9-18
    • /
    • 2020
  • Objectives : We tried to establish standards for genuine by discriminating 3 kinds of pollen and spore herbs that are highly to be mixed with each other. Using an scanning electron microscope, we prepare a standard for discriminating external morphological characters of minute herbs, thereby contributing to the stable supply of genuine herbal medicines. Methods : Standard samples were confirmed by literature review on external morphological characteristics of original plants and herbal medicines, and collection and identification of original plants. The herbal medicines on the market were purchased and classified with using naked eye observation and magnifier. Finally, micromorphological identifications were conducted using an scanning electron microscope. Results : 1. Pini Pollen was clearly distinguished by its relatively medium size and a pollen grain with two swollen reticulate sacci at both ends. The verrucate ornamentation on the exine surface of the corpus and a sunken leptoma germ pore may be used as a discrimination criteria. 2. Typhae Pollen was distinguished by its relatively small size and a saccus on the end of a pollen grain. Reticulate ornamentation of exine surface of the corpus, and a slightly clear ulcerate germ pore can be used as a discrimination criteria. 3. Lygodii Spora was distinguished by its relatively large triangular-ovate shape and trichotomous fissure. Verrucate-tuberculate ornamentation of exine surface and trilete aperture could be used as a discrimination criteria. Conclusion : These results indicate that the use of electron microscopy is very effective for discriminating the external morphology of minute herbal medicines.

Study on Characteristics of Snowfall and Snow Crystal Habits in the ESSAY (Experiment on Snow Storms At Yeongdong) Campaign in 2014 (2014년 대설관측실험(Experiment on Snow Storms At Yeongdong: ESSAY)기간 강설 및 눈결정 특성분석)

  • Seo, Won-Seok;Eun, Seung-Hee;Kim, Byung-Gon;Ko, A-Reum;Seong, Dae-Kyeong;Lee, Gyu-Min;Jeon, Hye-Rim;Han, Sang-Ok;Park, Young-San
    • Atmosphere
    • /
    • v.25 no.2
    • /
    • pp.261-270
    • /
    • 2015
  • Characteristics of snowfall and snow crystal habits have been investigated in the campaign of Experiment on Snow Storms At Yeongdong (ESSAY) using radiosonde soundings, Global Navigation Satellite System (GNSS), and a digital camera with a magnifier for taking a photograph of snowfall crystals. The analysis period is 6 to 14 February 2014, when the accumulated snowfall amount is 192.8 cm with the longest snowfall duration of 9 days. The synoptic situations are similar to those of the previous studies such as the Low pressure system passing by the far South of the Korean peninsula along with the Siberian High extending to northern Japan, which eventually results in the northeasterly or easterly flows and the long-lasting snowfall episodes in the Yeongdong region. In general, the ice clouds tended to exist below around 2~3 km with the consistent easterly flows, and the winds shifted to northerly~northwesterly above the clouds layer. The snow crystal habits observed in the ESSAY campaign were mainly dendrite, consisting of 70% of the entire habits. The rimed habits were frequently captured when two-layered clouds were observed, probably through the process of freezing of super-cooled droplets on the ice particles. The homogeneous habit such as dendrite was shown in case of shallow clouds with its thickness of below 500 m whereas various habits were captured such as dendrites, rimed dendrites, aggregates of dendrites, plates, rimed plates, etc in the thick cloud with its thickness greater than 1.5 km. The dendrites appeared to be dominant in the condition of cloud top temperature specifically ranging $-12{\sim}-16^{\circ}C$. However, the association of snow crystal habits with temperature and super-saturation in the cloud could not be examined in the current study. Better understandings of characteristics of snow crystal habits would contribute to preventing breakdown accidents such as a greenhouse destruction and collapse of a temporary building due to heavy snowfall, and traffic accidents due to snow-slippery road condition, providing a higher-level weather information of snow quality for skiers participating in the winter sports, and estimating more accurate snowfall amount, location, and duration with the fallspeed of solid precipitation.

Multi-focal Microscopic System Using a Fiber Bundle (광섬유 다발을 이용한 다초점 현미경)

  • Gu, Young-Mo;Ham, Hyo-Shick;Choi, Sung-Eul
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.354-360
    • /
    • 2009
  • We have constructed and analyzed the performance of a simple fiber bundle multi-focal microscope. The microscope had a fiber bundle substituted for micro-lens array that is the core part of MMM(multi-focal multi-photon microscope). The MMM is a type of confocal microscope. To analyze the performance and characteristics of the fiber bundle multi-focal microscope, three types of samples were used: a standard grating, USAF 1951(7, 3), and 1951(7, 6). Using two polarizers and a polarizing beam splitter, we eliminated noise and got clear images. We obtained the FWHM of fiber spot images with the standard grating using two different magnifier lenses which were 63X and 20X, and found an image of the sample as a distribution of fiber spot images. For this case we used the low magnification lens, which gives denser distribution, so that we could get clearer images. In order to test the resolution of the fiber bundle multi-focal microscopic system, we used the USAF 1951 sample which has a smaller line interval than that of the standard grating. The FWHM of the line width of the image coincides well with the real line width of the USAF 1951 sample. We confirmed the performance of a fiber bundle multi-focal microscopic system which is relatively simple but has submicron resolution and is able to get 1600 images at the same time.

THE COMPARISON OF CANAL SHAPING ABILITY BY ENGINE-DRIVEN NICKEL-TITANIUM FILE AND ENDOSONIC FILE IN CURVED CANAL (만곡 근관에서 엔진 구동용 Ni-Ti File과 초음파 기구에 의한 근관성형 능력의 비교)

  • Kim, Hyun-Ju;Oh, Won-Mann;Yang, Kyuo-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.758-767
    • /
    • 1995
  • The purpose of this study was to evaluate canal shaping ability after canal preparation by using engine-driven nickel-titanium file and endosonic file in curved canals. 30 mesiobuccal canals of molars extracted within recent 3 months were divided into 3 groups. Group I and group II were prepared by using engine-driven nickel-titanium Gates-Glidden drill type and the engine-driven nickel-titanium file type. Group III prepared by using en do sonic file. The image of preinstrumented canals was taken by X-ray. The image of postinstrumented canal was taken by X-ray in the same condition of preinstrumentation. A magnified X-ray image on magnifier screen was traced and then compared the preinstrumentated canal image with the postinstrumentated canal image by superimposing method. The following results were obtained : 1. In the change of canal curvature, the engine-driven nickel-titanium Gates-Glidden drill type showed the least change and the ultrasonically filing showed the greatest change. 2. In the percentage of canal enlargement, the engine-driven nickel-titanium file type was greatest at all level(p<0.05), the apex of all group was the greatest, the difference of ultrasonically filing group showed greater between apex and cervix. 3. The percentage of canal enlargement on convex side was greater than that of on concave side in apex of each group(p<0.05). In the ultrasonically filing group, both sides of canal enlargement showed sharply difference(p<0.01). 4. The percentage of canal enlargement on convex side was greater than that of on concave side in the third of cervix of the engine-driven nickel-titanium file type and the ultrasonically filling. The percentage of canal enlargement of convex and concave side in the third of middle of the engine-driven nickel-titanium Gates-Glidden drill type show a similar canal enlargement between convex side and concave side. As above result, the engine-driven nickel-titanium file type was greater in canal enlargement than the other instruments. The engine-driven nickel-titanium Gates-Glidden dirll type was efficient endodontic instrument for curved canal preparation because it was least change in canal curvature.

  • PDF

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.