• 제목/요약/키워드: Magnification ratio.

검색결과 100건 처리시간 0.029초

Comparison of Vertical Magnification Ratio among Various Areas in Panoramic Radiographs

  • Song, Woong-Kyu;Seok, Hwa-Suk;Kim, Byeong-Rin;Choi, Seong-Ho
    • Journal of Korean Dental Science
    • /
    • 제10권2호
    • /
    • pp.53-59
    • /
    • 2017
  • Purpose: The objective of the present article is to determine whether there are differences in vertical enlargement ratio among various sites within both jaws in a panoramic radiograph. Materials and Methods: Two hundred and seventy-threeimplant sites in panoramic radiographs were evaluated by two observers. Magnification ratios at various sites in both jaws were calculated and compared with each other. Result: The average vertical enlargement ratio in the panoramic radiograph was 1.264 and this value was larger than original ratio 1.250. Although vertical magnification ratio of maxillary molar area was higher than that of mandibular molar area, every group showed similar magnification ratio in clinical respect. Conclusion: Vertical magnification ratio of the maxillary molar area is statistically higher than that of the mandibular molar area in the panoramic radiograph, but it is clinically negligible.

표준필름과 Orthopantomograph의 상확대에 관한 비교 연구 (RELATIONSHIP OF IMAGE MAGNIFICATION BETWEEN PERIAPICAL STANDARD FILM AND ORTHOPANTOMOGRAM)

  • 김영태;박태원
    • 치과방사선
    • /
    • 제16권1호
    • /
    • pp.25-30
    • /
    • 1986
  • The author studied the magnification ratio of teeth length in orthopantomogram through intraoral film taken by standardized paral1eing technique. In this study, intraoral radiograph and orthopantomogram were taken in 2 cases of dry skull and 36 adults (504 teeth). 1. The obtained results were as follows: In case of dry skull, the magnification ratio of standard films was 4.6% to 5.9% and that of Orthopantomograph 5 was 15.1% to 33.1%. The magnification ratio of to the standard film was 9.2% to 26.5% 2. In case of adults, the magnification ratio of Orthopantomograph 5 to the standard films was 9.5% to 24.6%. 3. There were no significant difference in magnification between left and right. 4. Anterior teeth had lesser magnification than posterior teeth. 5. It was considered that teeth length showed in Orthopontomograph 5 was magnified 15.4% to 31.3% than actual teeth length.

  • PDF

유연 힌지를 이용한 이중레버 시스템의 변위증폭 메카니즘에 관한 연구 (A Study on the Displacement Magnification Mechanism of Two-Lever System using Flexure Hinge)

  • 제원수;예상돈;민병현
    • 한국기계가공학회지
    • /
    • 제7권2호
    • /
    • pp.60-65
    • /
    • 2008
  • The high-technology industries including a semi-conductor and an information communication need an ultra-precision technology from the technological points of view. Nano technology based on an ultra-precision technology is being studied to overcome the delicate technology that may occur in the semi-conductor fields. Then, the transferring equipment with high resolution and long displacement becomes an important technology. The goal of this study is to analyze the displacement magnification mechanism driven by piezoelectric actuator which has high resolution and fast response characteristics using flexure hinge with the merits of soft displacement, negligible back-lash and stick-slip, and no-lubrication. The analyses to reduce the magnification losses occurred during the magnification process are performed using ANSYS software based on FEM. The five design variables such as arm thickness, thickness of hinge, radius of hinge, length of input side at the 1st lever and magnification ratio of 1st lever are optimized to induce the maximum magnification ratio using Taguchi method.

  • PDF

디지털 유방확대촬영술에서 Air gap technique의 유용성 평가 (Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography)

  • 김미영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.101-107
    • /
    • 2014
  • 이 연구는 디지털 유방확대촬영술에서 방사선 피폭을 감소시키며 영상의 질을 유지하기 위한 최적의 촬영조건을 알아보았다. 자동노출방식의 평균유선선량이 수동노출방식에 비해 높은 것으로 나타났다. 자동노출방식은 그리드(grid) 사용 여부에 따라 평균유선선량과 화질평가에 차이가 많았으나, 수동노출방식은 팬텀영상평가 점수에서만 차이가 있었다. 그러나 air gap technique을 사용할 경우 모든 노출방식에서 신호대잡음비의 증가가 뚜렷하게 나타났다. 따라서 유방확대촬영 시 air gap technique을 사용한다면 환자의 평균유선선량을 감소시키고 신호대잡음비를 높여 양질의 화질을 유지할 수 있을 것이다.

삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구 (Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography)

  • 윤종태;이기백
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

초정밀 나노 스테이지에서의 다중 변위 확대 기구 해석 (Analysis of Multiple Displacement Magnification Mechanism in Ultraprecision Nano Stage)

  • 민경석;최우천
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1273-1276
    • /
    • 2005
  • A displacement magnification mechanism is usually employed in a nano-positioning stage to achieve a large stage motion. A lever mechanism is the most widely used displacement magnifying mechanism. For more large stage motion, double or multiple lever mechanisms can be used. In this case, a more accurate analysis model is needed. This study proposes a more reasonable analysis model for a multiple lever mechanism based on the single lever mechanism model. This paper describes that the high equivalent stiffness of the lever is the most important factor reducing the magnification ratio of the lever mechanism through increasing the deflection of the link and including the axial displacement of the pivot.

  • PDF

정밀 스테이지에서 출력변위 확대를 위한 레버의 해석 (Theoretical Analysis of Levers in a Precision Stage for Large Displacement)

  • 황은주;민경석;송신형;최우천
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.720-723
    • /
    • 2004
  • Lever mechanisms are usually employed to enlarge output displacement in precision stages. In this study, theoretical analysis of a lever is presented including bending effect and relation between dimension parameters and an objective function. The objective function is chosen as multiplication of magnification ratio and forcedisplacement transmission. Through theoretical analysis, this study presents optimal values for the parameters and the analysis is verified by finite element method.

  • PDF

유역배율에 따른 저수지의 하천유지용수 공급량 (Variation of water supply for instream flow from reservoirs with various magnifications of paddy irrigation area to watershed area)

  • 노재경;이재남
    • 농업과학연구
    • /
    • 제38권2호
    • /
    • pp.331-341
    • /
    • 2011
  • To provide variation of water supply for instream flow from reservoirs with various magnifications of paddy irrigation area to watershed area, 8 reservoirs were selected to draw operation rule curve and to analyze water supplies from reservoirs. Reliability of 90% for supplying irrigation water from reservoir was able to maintain and instream flow water was able to be supplied only in the reservoir with magnification of paddy irrigation area to watershed area above 3. The more magnification of paddy irrigation area to watershed area increased, the more ratio of irrigation water to total water storage decreased, and the more ratio of instream flow water to total water storage increased. From the heightening 113 reservoirs in Korea, annual irrigation water was estimated to 1,146.05 $Mm^3$ in normal operation, 839.57 $Mm^3$ in withdrawal limited operation, and annual instream flow water was estimated to 149.68 $Mm^3$ in normal operation, 283.19 $Mm^3$ in withdrawal limited operation. It was concluded that withdrawal limited operation was followed to have the premise of saving irrigation water, more instream flow water was able to be supplied from reservoirs with high magnification of paddy irrigation area to watershed area.

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • 제44권5호
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.

마찰감쇠기가 설치된 건물 응답의 근사해 : 재 고찰 및 새로운 결과 (Approximate solution for a building installed with a friction damper : revisited and new result)

  • 민경원;성지영;이성경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.850-854
    • /
    • 2009
  • Approximate analysis for a building installed with a friction damper is revisited to get insight of its dynamic behavior. Energy balance equation is used to have a closed analytical form solution of dynamic magnification factor (DMF) for the building with combined viscous and friction damping. It is found out that DMF is dependent on friction force ratio and resonance frequency. Linear transfer function from input external force to output building displacement is obtained by simplifying DMF equation. Root mean square of building displacement is derived under earthquake-like random excitation. Finally, design of friction damper is proposed by processing target control ratio, damping ratio factor, and friction force in sequence.

  • PDF