• Title/Summary/Keyword: Magnetostriction

Search Result 166, Processing Time 0.035 seconds

Magnetostriction Measurement of an $Fe_49Co_49V_2$ Alloy using the Michelson Laser Interferometer Compensated by Feedback Signal (궤환신호로 보상되는 Michelson 레이저 간섭계를 이용한 $Fe_49Co_49V_2$ 합금의 자기변형 측정)

  • 안승준;김철기;김호섭;김호철;남궁정
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.246-249
    • /
    • 2000
  • An Fe$_{49}$ Co$_{49}$ V$_2$alloy is annealed in thermal annealing furnace at 50$0^{\circ}C$, 75$0^{\circ}C$, 80$0^{\circ}C$, and 90$0^{\circ}C$. Annealed samples were cooled in air. The magnetostriction is measured by using a Michelson laser interferometer. Receiving the feedback signal of interference, a mirror attached to piezoelectric transducer (PZT) maintains the optical path length (OPL) between two arms of laser interferometer relatively constant. The feedback voltage is calibrated to the OPL variation. A magnetostriction of 2$\times$10$^{-6}$ at H = 60 Oe increases up to 33.68$\times$10$^{-6}$ at an annealing temperature of 90$0^{\circ}C$, suggesting that the magnetostrictive characteristics are improved by the microstructural modification.

  • PDF

Dynamic Magnetostriction Characteristics of an Fe-Based Nanocrystalline FeCuNbSiB Alloy

  • Chen, Lei;Li, Ping;Wen, Yumei
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.211-215
    • /
    • 2011
  • The dynamic magnetostriction characteristics of an Fe-based nanocrystalline FeCuNbSiB alloy are investigated as a function of the dc bias magnetic field. The experimental results show that the piezomagnetic coefficient of FeCuNbSiB is about 2.1 times higher than that of Terfenol-D at the low dc magnetic bias $H_{dc}$ = 46 Oe. Moreover, FeCuNbSiB has a large resonant dynamic strain coefficient at quite low Hdc due to a high mechanical quality factor, which is 3-5 times greater than that of Terfenol-D at the same low $H_{dc}$. Based on such magnetostriction characteristics, we fabricate a new type of transducer with FeCuNbSiB/PZT-8/FeCuNbSiB. Its maximum resonant magnetoelectric voltage coefficient achieves ~10 V/Oe. The ME output power reaches 331.8 ${\mu}W$ at an optimum load resistance of 7 $k{\Omega}$ under 0.4 Oe ac magnetic field, which is 50 times higher than that of the previous ultrasonic-horn-substrate composite transducer and it decreases the size by nearly 86%. The performance indicate that the FeCuNbSiB/PZT-8/FeCuNbSiB transducer is promising for application in highly efficient magnetoelectric energy conversion.

Noise Analyses of VVVF Inverter and DC/DC Converter for Maglev Train (자기부상열차용 VVVF 인버터 및 DC/DC 컨버터의 소음해석)

  • 김현실;김재승;강현주;김봉기;김상렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.337-344
    • /
    • 2003
  • In DC/DC converter and VVVF inverter, which are the must dominant noise sources of Maglev train, noise is radiated from core and coil excited by MS(Magnetostriction). The main noise source of DC/DC converter is transformer whose spectrum shows strong peaks associated with harmonics of exciting frequency, On the other hand, LIM/VVVF noise is dominated by the harmonics of switching frequency, whereas harmonics of exciting frequency are not significant. As switching frequency is increased in VVVF inverter, it is shown that the harmonics are shifted to higher frequency range. If switching frequency is increased from 700㎐ to 2 ㎑, It is measured that noise can be reduced by 5 to 6 ㏈. Since complete mathematical description of MS phenomena is far beyond the present technology, vibration spectrum is investigated qualitatively in this paper, where effect of increasing switching frequency is confirmed.