• Title/Summary/Keyword: Magnetoelastic biosensor

Search Result 3, Processing Time 0.03 seconds

Novel Approach of a Phage-Based Magnetoelastic Biosensor for the Detection of Salmonella enterica serovar Typhimurium in Soil

  • Park, Mi-Kyung;Chin, Bryan A.
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.12
    • /
    • pp.2051-2059
    • /
    • 2016
  • To date, there has been no employment of a magnetoelastic (ME) biosensor method to detect Salmonella enterica serovar Typhimurium in soil. The ME biosensor method needs to be investigated and modified for its successful performance. The filtration method, cation-exchange resin method, and combinations of both methods were employed for the extraction of S. Typhimurium from soil. The number of S. Typhimurium and the resonant frequency shift of the ME sensor were then compared using a brilliant green sulfa agar plate and an HP 8751A network analyzer. A blocking study was performed using bovine serum albumin (BSA), polyethylene glycol (PEG), and casein powder suspension. Finally, the modified ME biosensor method was performed to detect S. Typhimurium in soil. The number of S. Typhimurium was significantly decreased from 7.10 log CFU/soil to 4.45-4.72 log CFU/soil after introduction of the cation-exchange resin method. The greatest resonant frequency shift of the measurement sensor was found when employing centrifugation and filtration procedures. The resonant frequency shift of the PEG-blocked measurement sensor was $3,219{\pm}755Hz$, which was significantly greater than those of the BSA- and casein-blocked ME sensor. The optimum concentration of PEG was determined to be 1.0 mg/ml after considering the resonant shift and economic issue. Finally, the modified ME biosensor method was able to detect S. Typhimurium in soil in a dose-response manner. Although these modifications of the ME biosensor method sacrificed some advantages, such as cost, time effectiveness, and operator friendliness, this study demonstrated a novel approach of the ME biosensor method to detect S. Typhimurium in soil.

Exploring the feasibility of Salmonella Typhimurium-specific phage as a novel bio-receptor

  • Choi, In Young;Park, Do Hyeon;Chin, Brayan A.;Lee, Cheonghoon;Lee, Jinyoung;Park, Mi-Kyung
    • Journal of Animal Science and Technology
    • /
    • v.62 no.5
    • /
    • pp.668-681
    • /
    • 2020
  • The purpose of this study was aimed to isolate a Salmonella Typhimurium-specific phage (KFS-ST) from washing water in a poultry processing facility and to investigate the feasibility of the KFS-ST as a novel bio-receptor for the magnetoelastic (ME) biosensor method. KFS-ST against S. Typhimurium was isolated, propagated, and purified using a CsCl-gradient ultracentrifugation. Morphological characteristics of KFS-ST were analyzed using transmission electron microscopy (TEM). Its specificity and efficiency of plating analysis were conducted against 39 foodborne pathogens. The temperature and pH stabilities of KFS-ST were investigated by the exposure of the phage to various temperatures (-70℃-70℃) and pHs (1-12) for 1 h. A one-step growth curve analysis was performed to determine the eclipse time, latent time and burst size of phage. The storage stability of KFS-ST was studied by exposing KFS-ST to various storage temperatures (-70℃, -20℃, 4℃, and 22℃) for 12 weeks. KFS-ST was isolated and purified with a high concentration of (11.47 ± 0.25) Log PFU/mL. It had an icosahedral head (56.91 ± 2.90 nm) and a non-contractile tail (225.49 ± 2.67 nm), which was classified into the family of Siphoviridae in the order of Caudovirales. KFS-ST exhibited an excellent specificity against only S. Typhimurium and S. Enteritidis, which are considered two of the most problematic Salmonella strains in the meat and poultry. However, KFS-ST did not exhibit any specificity against six other Salmonella and 27 non-Salmonella strains. KFS-ST was stable at temperature of 4℃ to 50℃ and at pH of 4 to 12. The eclipse time, latent time, and burst size of KFS-ST were determined to be 10 min, 25 min and 26 PFU/ infected cell, respectively. KFS-ST was relatively stable during the 12-week storage period at all tested temperatures. Therefore, this study demonstrated the feasibility of KFS-ST as a novel bio-receptor for the detection of S. Typhimurium and S. Enteritidis in meat and poultry products using the ME biosensor method.