• Title/Summary/Keyword: Magnetizing analysis

Search Result 121, Processing Time 0.027 seconds

A Circuit of Capacitor-Discharge Impulse Magnetizer and Magnetizing Characteristics of Ferrite Magnet (커패시터 방전 임펄스 착자기 회로와 페라이트 자석의 착자특성)

  • Baek, Su-Hyeon;Yun, Su-Bong;Kim, Pil-Su
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.645-648
    • /
    • 1992
  • In a capacitor-discharge impulse magnetizer, one of the magnetic application system, a magnet is magnetized by the discharging current of capacitors. The conventional design of the magnetizer has been based on many year's experience. The behaviour of flux in the magnetizer should be calculated in order to produce the desired magnets. The analysis of the flux distribution is quite difficult. This is because both the magnetizing current and the applied voltage to the magnetizer are unknown. This paper describes the development of computer model for a capacitor-discharge impulse magnetizer using SPICE. Also, the detailed distribution of the flux density in a magnet magnetized by the impulse magnetizer be analyed.

  • PDF

Design and Analysis of Magnetizing Machine for High Speed Permanent Machines (초고속 영구자석 회전기의 회전자 착자기 설계 및 해석)

  • Jung, Soo-Jin;Kang, Do-Hyun;Kim, Dong-Hee;Jeong, Yeon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.586-589
    • /
    • 2001
  • In Case of High speed PM machines with surface-mounted magnet. A rare-earth PM with high remanence flux density is used on the rotor. Therefore, It is very difficult to adhesion and assemble PM on the surface of rotor, because of very repulsive force between magnets. So, for solving this problem, rotor with surface-mounted magnet is wholly magnetized after mounting magnetic-material on the surface. In this paper, In order to Magnetize rotor with surface-mounted PM, magnetizing machine is designed, analyzed and simulated for large PM machines using the 1dimensional analytical method and 2dimensional finite element method. (20-FEM).

  • PDF

Characteristics Magnetic Flux Leakage According to the Position of Hall Sensor (Hall 센서 위치에 따른 MFL 특성 고찰)

  • Kim, Sean;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.819-821
    • /
    • 2001
  • This paper describes a characteristics of MFL according to the position of Hall sensor Magnetic Flux Leakage(MFL) Method is used to detect surface defect in ferromagnetic plate. A plate has a surface defect and magnetizing equipment are producted to perform Non-Destructive Testing(NDT) using MFL. The SM 45C carbon steel plate is adopted to this experiment. there is a artifical defect with a twice of thickness and a half of depth of plate. Magnetizing equipment is composed of yoke made by layer-built of silicon sheet steel, NdFeB magnetic and iron brushes. Detecting defect is performed by MFL NDT using Hall sensor. It is shown that magnetic flux detected by Hall sensor is affected according to the position of Hall sensor through MFL experiment and numerical analysis.

  • PDF

Modeling and Control of Three-Phase Self-Excited Induction Generator Connected to Grid

  • Chandrasekaran, Natarajan;Karthikeyan, A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.265-272
    • /
    • 2017
  • This paper presents the dynamic modeling, analysis, and control of an AC/DC/AC-assisted, self-excited induction generator connected to the grid. The dynamic model includes wind turbine models with pitch control, gear boxes, self-excited induction generators, excitation capacitance, inductive load models, controlled six-pulse rectifiers, and novel state-space models of a grid-connected inverter. The system has been simulated to verify its capabilities of buildup voltage, stator flux response, stator phase current, electromagnetic torque, and magnetizing inductance variation during both the dynamic and steady states with a variable-speed prime mover. The complete setup of the above dynamic models was simulated using MATLAB/SIMULINK.

An Improved Soft-Switching Inverter with An Unidirectional Auxiliary Switch (단방향 보조 스위치를 갖는 개선된 소프트 스위칭 인버터)

  • Sohn, Se-Jin;Lee, Kui-Jun;Kim, Rae-Young;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.376-377
    • /
    • 2010
  • In this paper, novel unidirectional auxiliary resonant commutated pole is proposed to improve the performance of zero-voltage soft-switching inverter. The proposed circuit keeps the advantages of the original soft-switching inverter, while providing more effective resetting capability in magnetizing current. Based on the advanced reset mechanism, auxiliary switches operate under a complete zero-current condition. The operating principle and steady-state analysis are presented theoretically, according to its operating modes. Accordingly, it proves the fact that the proposed unidirectional auxiliary resonant commutated pole breaks an unwanted magnetizing current loop effectively. The performance of the proposed circuit is verified by several simulation results.

  • PDF

Non-destructive Testing and Numerical Analysis for Ferromagnetic Plates using Magnetic Flux Leakage Method (강자성체 평판의 자속 누설 탐상 비파괴 실험 및 수치해석)

  • Kim, Sean;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.126-128
    • /
    • 2001
  • In this paper, Magnetic Flux Leakage(MFL) method is used to detect surface defect in ferromagnetic plate. Surface defects are created on the SM 45C ferromagnetic plate and magnetizing equipment is composed to perform MFL nondestructive testing. The length and width of defect is twice the thickness of ferromagnetic plate, and defects with different depths are made artificially for the experiment. Also, NdFeB magnet in magnetizing equipment is used to make magnetic flux. This paper shows that it is possibile to detect 10% defect and to analyze numerically for any defect using MFL method.

  • PDF

Harmonics Analysis of Magnetostriction in 3% SiFe

  • Kim, C.G.;Ahn, S.J.;Jeong, M.H.;Kim, H.C.;Cha, S.Y.;Chang, S.K.
    • Journal of Magnetics
    • /
    • v.3 no.4
    • /
    • pp.120-122
    • /
    • 1998
  • The higher order harmonic components of magnetostriction during ac magnetization in 3% SiFe are measured as a function of the magnetizing angle respect to [001] axis using a constructed laser interferometry. The magnetostriction with magnetizing angle from [001] axis agrees ith the calculation based on domain reorientation. The relative amplitudes of odd and even harmonics respectively for magnetic induction and magnetostriction decrease with the order of harmonics, accompanying the contraction of the amplitudes. The contraction of harmonics order of magnetostriction harmonics is shown to be the even number times of that of magnetic induction.

  • PDF

A Comparative Analysis of Fuzzy Logic-Based Relaying and Wavelet-Based Relaying for Large Transformer Protection (대용량 변압기 보호용 퍼지논리 계전기법과 웨이브렛 계전기법의 비교 분석)

  • Park, Chul-Won;Park, Jae-Sae;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.4
    • /
    • pp.179-188
    • /
    • 2003
  • Percentage differential characteristic scheme has been recognized as the principal basis for large transformer protection. Nowadays, relaying signals can contain second harmonic component to a large extent even in a normal state, and second harmonic ratio indicates a tendency of relative reduction because of the advancement of transformer's core material. And then, conventional second harmonic restraint differential relaying exposes some doubt in reliability. It is, therefore, necessary to develop a new algorithm for the effective and accurate discrimination. This paper deals with advanced fuzzy logic based relaying by using flux differential, and a new fault detection criterion logic scheme by using wavelet transform. To comparative analysis of proposed techniques, the paper constructs power system model including power transformer, utilizing the EMTP, and collects data through simulation of various internal faults and magnetizing inrush. The proposed fuzzy relaying and a new fault detection scheme were tested. The former, fuzzy relaying, was proven to be faster and more reliable than the latter.

Analysis of cross magnetizing effect on the generator characteristics (발전기 특성에 미치는 교차자화 포화현상의 영향 해석)

  • Kim, Deok-Young;Rho, Kyu-Min;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1224-1227
    • /
    • 1998
  • This paper presents an effect of cross magnetization to the generator characteristics in synchronous machine infinite bus system. Eigenvalues, synchronous torque and damping torque are investigated as the operating condition of the system is changed variously. The simulation results show that cross magnetization has an important effect to the generator characteristics in steady state stability analysis.

  • PDF