• Title/Summary/Keyword: Magnetic-bias

Search Result 266, Processing Time 0.037 seconds

Co-Fe-B 자왜변환기를 이용한 간섭계형 광섬유 자계센서의 동작특성

  • 이경식
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.474-479
    • /
    • 1993
  • An interferometric fiber-optic magnetic field sensor is constructed by bonding a Co-Fe-B metallic glass transducer developed here by the melt-spun method to a single mode fiber arm in the fiber Mach-Zehnder interferometer and is tested. The bias field for the peak ac-sensitivity was observed near 0.97 Oe and the minimum detectable magnetic field was 3.9${\times}10^{-5}$ Oe(rms)/${\sqrt{Hz}}$ a 3 kHz. The output of the ac field sensor becomes saturated near the input signal level of 1 Oe(rms). The Co- Fe-B transducer exhibits peak response near 500 Hz.

  • PDF

CoFeB과 IrMn 자성 박막의 고밀도 반응성 이온 식각

  • Kim, Eun-Ho;So, U-Bin;Gong, Seon-Mi;Jeong, Yong-U;Jeong, Ji-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.232-232
    • /
    • 2010
  • 정보화 산업의 발달은 DRAM, flash memory 등을 포함한 기존의 반도체 메모리 소자를 대체할 수 있는 차세대 메모리 소자에 대한 개발을 요구하고 있다. 특히 magnetic random access memory (MRAM)는 SRAM과 대등한 고속화 그리고 DRAM 보다 높은 기록 밀도가 가능하고 낮은 동작 전압과 소비전력 때문에 대표적인 차세대 비휘발성 메모리로 주목받고 있다. 또한 MRAM소자의 고집적화를 위해서 우수한 프로파일을 갖고 재증착이 없는 나노미터 크기의 magnetic tunnel junction (MTJ) stack의 건식 식각에 대한 연구가 선행되어야 한다. 본 연구에서는 고밀도 반응성 이온 식각법(Inductively coupled plasma reactive ion etching; ICPRIE)을 이용하여 재증착이 없이 우수한 식각 profile을 갖는 CoFeB과 IrMn 박막을 형성하고자 하였다. Photoresist(PR) 및 Ti 박막의 두 가지 마스크를 이용하여 HBr/Ar, HBr/$O_2$/Ar 식각 가스들의 농도를 변화시키면서 CoFeB과 IrMn 박막의 식각 특성들이 조사되었다. 자성 박막과 동일한 조건에 대하여 hard mask로서 Ti가 식각되었다. 좋은 조건을 얻기 위해 HBr/Ar 식각 가스를 이용 식각할 때 pressure, bias voltage, rf power를 변화시켰고 식각조건에서 Ti 하드마스크에 대한 자성 박막들의 selectivity를 조사하고 식각 profile을 관찰하였다. 식각 속도를 구하기 위해 alpha step(Tencor P-1)이 사용되었고 또한 field emission scanning electron microscopy(FESEM)를 이용하여 식각 profile을 관찰함으로써 최적의 식각 가스와 식각 조건을 찾고자 하였다.

  • PDF

SI-BASED MAGNETIC TUNNELING TRANSISTOR WITH HIGH TRANSFER RATIO

  • S. H. Jang;Lee, J. H.;T. Kang;Kim, K. Y.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.24-24
    • /
    • 2003
  • Metallic magnetoelectronic devices have studied intensively and extensively for last decade because of the scientific interest as well as great technological importance. Recently, the scientific activity in spintronics field is extending to the hybrid devices using ferromagnetic/semiconductor heterostructures and to new ferromagnetic semiconductor materials for future devices. In case of the hybrid device, conductivity mismatch problem for metal/semiconductor interface will be able to circumvent when the device operates in ballistic regime. In this respect, spin-valve transistor, first reported by Monsma, is based on spin dependent transport of hot electrons rather than electron near the Fermi energy. Although the spin-valve transistor showed large magnetocurrent ratio more than 300%, but low transfer ratio of the order of 10$\^$-5/ prevents the potential applications. In order to enhance the collector current, we have prepared magnetic tunneling transistor (MTT) with single ferromagnetic base on Si(100) collector by magnetron sputtering process. We have changed the resistance of tunneling emitter and the thickness of baser layer in the MTT structure to increase collector current. The high transfer ratio of 10$\^$-4/ range at bias voltage of more than 1.8 V, collector current of near l ${\mu}$A, and magnetocurrent ratio or 55% in Si-based MTT are obtained at 77K. These results suggest a promising candidate for future spintronic applications.

  • PDF

Detection of Magnetic Bacteria Using PHR Sensors with Trilayer Structure (삼층박막 구조의 PHR 센서를 이용한 자기 박테리아 감지)

  • Yoo, Sang Yeob;Lim, Byeong Hwa;Song, In Cheol;Kim, Cheol Gi;Oh, Sun Jong
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.6
    • /
    • pp.200-204
    • /
    • 2013
  • In this study, we have fabricated magnetoresistive sensors of $50{\mu}m{\times}50{\mu}m$ cross type by trilayer structure of antiferromagnetic/nonmagnetic/ferromagnetic. The magnetic signal and magnetic domain of this sensor is measured. The sensor hysteresis loop is not in symmetrical at 0 Oe. This is may be due to the exchange coupling between ferromagnetic layer and anti ferromagnetic layer. This exchange bias value is 20 Oe. The sensor signal is measured at between the applied magnetic field and current. The sensor signal is measured between the applied magnetic field and current at $20^{\circ}$ and $90^{\circ}$ angles. The sensitivity of sensor signals is $20{\mu}V/Oe$ and $7{\mu}V/Oe$ at $20^{\circ}$ and $90^{\circ}$ angles, respectively. In addition, this sensor is also applied for the detection of magnetic bacteria at $20^{\circ}$ angle. From these results, we calculate the stray field of single bacteria is to be $5{\times}10^{-5}$Oe.

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF

Comparative Study of Performance of Switching Control and Synchronous Notch Filter Control for Active Magnetic Bearings (능동 자기 베어링을 위한 동기 노치필터 제어기와 스위칭 제어기의 성능 비교 연구)

  • Yoo, Seong Yeol;Noh, Myounggyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.511-519
    • /
    • 2013
  • Switching controllers for active magnetic bearings are claimed to minimize the copper losses because they do not use bias currents. In this study, we compare the performances of the switching controller with those of the widely used proportional-derivative (PD) controller. The PD controller is combined with a synchronous notch filter to reduce the effect of the unbalance disturbance. For a fair and objective comparison, the PD controller is designed systematically. The switching controller is designed so that the dynamics of the two controllers are almost identical. A system model is developed. This model includes the flexible modes of the rotor and the dynamics of the sensors and amplifiers. The simulation results show that the switching controller indeed reduces the copper loss at lower speeds. However, it fails to operate around the speed close to the bending mode of the rotor.

Inductively Coupled Plasma Reactive Ion Etching of MgO Thin Films Using a $CH_4$/Ar Plasma

  • Lee, Hwa-Won;Kim, Eun-Ho;Lee, Tae-Young;Chung, Chee-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.77-77
    • /
    • 2011
  • These days, a growing demand for memory device is filled up with the flash memory and the dynamic random access memory (DRAM). Although DRAM is a reasonable solution for current demand, the universal novel memory with high density, high speed and nonvolatility, needs to be developed. Among various new memories, the magnetic random access memory (MRAM) device is considered as one of good candidate memories because of excellent features including high density, high speed, low operating power and nonvolatility. The etching of MTJ stack which is composed of magnetic materials and insulator such as MgO is one of the vital process for MRAM. Recently, MgO has attracted great interest in the MTJ stack as tunneling barrier layer for its high tunneling magnetoresistance values. For the successful realization of high density MRAM, the etching process of MgO thin films should be investigated. Until now, there were some works devoted to the investigations on etch characteristics of MgO thin films. Initially, ion milling was applied to the etching of MgO thin films. However, ion milling has many disadvantages such as sidewall redeposition and etching damage. High density plasma etching containing the magnetically enhanced reactive ion etching and high density reactive ion etching have been employed for the improvement of etching process. In this work, inductively coupled plasma reactive ion etching (ICPRIE) system was adopted for the improvement of etching process using MgO thin films and etching gas mixes of $CH_4$/Ar and $CH_4$/$O_2$/Ar have been employed. The etch rates are measured by a surface profilometer and etch profiles are observed using field emission scanning emission microscopy (FESEM). The effects of gas concentration and etch parameters such as coil rf power, dc-bias voltage to substrate, and gas pressure on etch characteristics will be systematically explored.

  • PDF

Study on Transformer and Inductor Using Equivalent Air gap to Partial Flux Saturation (국부적 자속 포화 현상을 이용한 리엑터 및 변압기의 공극 등가 모델에 관한 연구)

  • Park, Sung-Jun;Lee, Sang_Hun;Kim, Jeong-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.3
    • /
    • pp.103-112
    • /
    • 2014
  • BY the Transformers and reactors, the input electrical energy is converted into magnetic energy. At the end through the magnetic energy was passed at the output parameter. Specially At the flyback transformer or a reactor airgap were designed to contain more magnetic energy. But that work is very difficult for the optimal design. It is that Contradictions are between the length of the Air-gap, Winding inductance, DC bias. As to e Several conflicting conditions in order to determine the optimum Air-gap has a lot of experience and trial & error is necessary. The approach proposed in this paper, the auxiliary winding on the core attached to part of primary core, that by applying a DC voltage has a dramatic effect like Core with designed Air-gap. This inventiveness and advantage is to regulate arbitrarily the Saturation Flux Quantity by the input signal to secondary winding. Accordingly obtained the biggest effect is that increasing limits of the saturation current destined by the material and shape of the conventional core. In other words, that can decreas the size of the transformer and reactor, While maintaining the current saturation capacity. This paper, prove its effect as using the local flux saturation in transformers and reactors for research by the computer program using the finite element method (FEM) simulation, followed by actual experiment to verify

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

Cardiovascular Magnetic Resonance Versus Histopathologic Study for Diagnosis of Benign and Malignant Cardiac Tumours: A Systematic Review and Meta-Analysis

  • Sandra Nobrega;Catarina Martins da Costa;Ana Filipa Amador;Sofia Justo;Elisabete Martins
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.159-168
    • /
    • 2023
  • BACKGROUND: The gold standard for diagnosis of cardiac tumours is histopathological examination. Cardiovascular magnetic resonance (CMR) is a valuable non-invasive, radiation-free tool for identifying and characterizing cardiac tumours. Our aim is to understand CMR diagnosis of cardiac tumours by distinguishing benign vs. malignant tumours compared to the gold standard. METHODS: A systematic search was performed in the PubMed, Web of Science, and Scopus databases up to December 2022, and the results were reviewed by 2 independent investigators. Studies reporting CMR diagnosis were included in a meta-analysis, and pooled measures were obtained. The risk of bias was assessed using the Quality Assessment Tools from the National Institutes of Health. RESULTS: A total of 2,321 results was obtained; 10 studies were eligible, including one identified by citation search. Eight studies were included in the meta-analysis, which presented a pooled sensitivity of 93% and specificity of 94%, a diagnostic odds ratio of 185, and an area under the curve of 0.98 for CMR diagnosis of benign vs. malignant tumours. Additionally, 4 studies evaluated whether CMR diagnosis of cardiac tumours matched specific histopathological subtypes, with 73.6% achieving the correct diagnosis. CONCLUSIONS: To the best of our knowledge, this is the first published systematic review on CMR diagnosis of cardiac tumours. Compared to histopathological results, the ability to discriminate benign from malignant tumours was good but not outstanding. However, significant heterogeneity may have had an impact on our findings.