• Title/Summary/Keyword: Magnetic wireless communication

Search Result 91, Processing Time 0.028 seconds

Design of Miniaturized Magnetic Field Probe for Measurement of IC Surface Current Distribution (IC 표면 전류 분포 측정을 위한 초소형 자기장 프로브 설계)

  • Lee, Seung-Bae;Jeon, Young-Hyun;Kim, Byung-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.5
    • /
    • pp.154-161
    • /
    • 2009
  • Recently, as many functional blocks are integrated on a small area the high speed integrated circuits emerge as a critical electromagnetic interferer which causes mal-function of adjacent circuitries and lowers the sensitivity of the wireless receivers. Therefore, it is necessary to devise an precise analyzing tool to pinpoint the major electromagnetic noise contributor among the internal circuit blocks of high speed IC's. This paper presents the design, fabrication, and measurement results of the high resolution magnetic field probe which can measure the current density on the IC surface. In order to achieve the high resolution, the magnetic field probe is fabricated using 3-metal semiconductor process so that its thickness is reduced by 10% than that of conventional works. Through the magnetostatic analysis and EM simulation, spatial resolution and sensitivity to the nonmagnetic field components are analyzed. Experimentally, it is found that the fabricated probe can measure the current density on the IC surface with $210{\mu}m$-spatial-resolution.

Reforming Method and Proposal for the Technical Regulation of Extremely Electric Filed Strength Radio Equipment below 135kHz (135kHz 이하 미약 전계강도 무선기기 기술기준 개선 방안 및 제안)

  • Kim, Sun-Youb;Jeoung, Chan-Gwoun;Kang, Young-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • This paper analyzed the problems of the Korean output regulation in the relevant band through an analytic comparison of the current trend of each country and their standard values concerning electric field strength (technical standard) of weak wireless stations with less than 135kHz. In connection with the standard value of electric field strength of each country, which has been proposed in the registration of the appropriate electric wave, the paper aims to propose the standard value of electric field strength that could actually be introduced for suitable unauthorized wireless devices (weak wireless devices) in Korea. Provided that the Korean standard may be upgraded based on the tolerances of electric field strength proposed m this paper, this is expected to be committed to the distribution and advancement of weak wireless devices; and further it is anticipated to be prepared with competitiveness not only in the Korean communications market, but also in the international communications market.

Development of JPEG2000 Viewer for Mobile Image System (이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발)

  • 김새롬;정해조;강원석;이재훈;이상호;신성범;유선국;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.124-130
    • /
    • 2003
  • Currently, as a consequence of PACS (Picture Archiving Communication System) implementation many hospitals are replacing conventional film-type interpretations of diagnostic medical images with new digital-format interpretations that can also be saved, and retrieve However, the big limitation in PACS is considered to be the lack of mobility. The purpose of this study is to determine the optimal communication packet size. This was done by considering the terms occurred in the wireless communication. After encoding medical image using JPGE2000 image compression method, This method embodied auto-error correction technique preventing the loss of packets occurred during wireless communication. A PC class server, with capabilities to load, collect data, save images, and connect with other network, was installed. Image data were compressed using JPEG2000 algorithm which supports the capability of high energy density and compression ratio, to communicate through a wireless network. Image data were also transmitted in block units coeded by JPEG2000 to prevent the loss of the packets in a wireless network. When JPGE2000 image data were decoded in a PUA (Personal Digital Assistant), it was instantaneous for a MR (Magnetic Resonance) head image of 256${\times}$256 pixels, while it took approximately 5 seconds to decode a CR (Computed Radiography) chest image of 800${\times}$790 pixels. In the transmission of the image data using a CDMA 1X module (Code-Division Multiple Access 1st Generation), 256 byte/sec was considered a stable transmission rate, but packets were lost in the intervals at the transmission rate of 1Kbyte/sec. However, even with a transmission rate above 1 Kbyte/sec, packets were not lost in wireless LAN. Current PACS are not compatible with wireless networks. because it does not have an interface between wired and wireless. Thus, the mobile JPEG2000 image viewing system was developed in order to complement mobility-a limitation in PACS. Moreover, the weak-connections of the wireless network was enhanced by re-transmitting image data within a limitations The results of this study are expected to play an interface role between the current wired-networks PACS and the mobile devices.

  • PDF

Bidirectional Magnetic Wireless Communication System based on Inductive Power Transfer System (자기유도 전력전달 시스템 기반 양방향 자기장 무선통신 시스템)

  • Choi, Byeung G.;Lee, Eun S.;Rim, Chun T.
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.56-58
    • /
    • 2015
  • 본 논문은 자기유도 무선전력 전송하에 송수신부간 양방향 자기장 무선통신 시스템을 제안한다. 송수신부의 무선전력전송 중 양방향 무선통신은 수신부가 장착된 전자기기의 무선충전시 수신부의 안정적인 전력공급 측면에서 필수적이다. 제안하는 양방향 자기장 무선통신 시스템은 송수신부간 복잡한 IC 회로 또는 추가적인 무선통신회로 없이 단순 공진 필터 및 통신용 변압기만을 이용하여 외부환경에 강인하면서도 경제적인 무선통신이 가능하다. 본 논문에서는 제안하는 자기장 무선통신 시스템의 전력선 및 통신선 등가회로를 각각 분석하였고 실험 및 시뮬레이션을 통해 그 타당성을 검증하였다.

  • PDF

Design of UWB Antenna for the External Receiver of Capsule Endoscopy (캡슐 내시경의 외부 수신기용 UWB 안테나 설계)

  • Kim Hong-Seok;Oh Min-Seok;Cheon Chang-Yul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.790-796
    • /
    • 2005
  • In order to accomplish a wireless communication of capsule endoscopy, an environment study in the human body and receiving antenna design have been performed. The proposed antenna is the loop antenna designed to minimize the propagation loss in multi-loss layer such as the human body and utilize the magnetic field. Considering the propagation loss in the human body, the frequency range is from 400 MHz to 500 MHz. Acorrrding to the FCC regulations, the permittivity and conductivity for each human tissue were extracted. We set up an equivalent model and make an aqueous solution which is replaced with the human body. Due to movement of capsule in the human body which propagation loss is extremly severe, an array antenna is required. Irrespective of the location of transmission antenna transmitting a signal of 1 mW, we confirme what it is possible for the enough signal detection as the average signal level of array antenna is -60 dBm.

A Conductive-grid based EMI Shielding Composite Film with a High Heat Dissipation Characteristic (전도성 그리드를 활용한 전자파 흡수차폐/방열 복합소재 필름)

  • Park, Byeongjin;Ryu, Seung Han;Kwon, Suk Jin;Kim, Suryeon;Lee, Sang Bok
    • Composites Research
    • /
    • v.35 no.3
    • /
    • pp.175-181
    • /
    • 2022
  • Due to the increasing number of wireless communication devices in mmWave frequency bands, there is a high demand for electromagnetic interference (EMI) shielding and heat dissipating materials to avoid device malfunctions. This paper proposes an EMI shielding composite film with a high heat dissipation characteristic. To achieve this, a conductive grid is integrated with a polymer-based composite layer including magnetic and heat dissipating filler materials. A high shielding effectiveness (>40 dB), low reflection shielding effectiveness (<3 dB), high thermal conductivity (>10 W/m·K), thin thickness (<500 ㎛) are simultaneously achieved with a tailored design of composite layer compositions and grid geometries in 5G communication band of 26.5 GHz.

Color Space Mapping and Medium Access Control Techniques in Visible Light Communication (가시광통신을 위한 색채공간매핑과 MAC 기법 연구)

  • Rahman, Mohammad Shaifur;Kim, Byung-Yeon;Bang, Min-Suk;Park, Young-Il;Kim, Ki-Doo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.99-107
    • /
    • 2009
  • Visible Light Communication (VLC) is a promising wireless communication technology. It offers huge, worldwide available and free bandwidth without electro-magnetic interference, which makes it very attractive for RF-sensitive operating environments. We propose colored LED-based VLC system for hospital use which includes voice recognition system for operating the medical equipments. New Mr hlation Scheme based on the Light Color Space is suggested to overcome the effect of noise generated by background light. Different color space constellations for different symbol sizes are also suggested which would give better bit error rate performance. Finally, Slotted ALOHA or TDMA medium access control protocols are suggested for multi-user operations.

  • PDF

Analysis and Application of Compact Planar Multi-Loop Self-Resonant Coil of High Quality Factor with Coaxial Cross Section (고품질 계수를 갖는 소형 평판형 동축 단면 다중 루프 자기 공진 코일 해석 및 응용)

  • Son, Hyeon-Chang;Kim, Jinwook;Kim, Do-Hyeon;Kim, Kwan-Ho;Park, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.4
    • /
    • pp.466-473
    • /
    • 2013
  • In this paper, a compact planar multi-loop self-resonant coil of high quality factor with a coaxial cross section is proposed for effective wireless charging. The proposed coil has high Q-factor and a resonant frequency of a coil can be easily controlled by adjusting distributed capacitance. For designing the coil, a self-inductance and a distributed capacitance are calculated theoretically. The self-inductance is calculated from the sum of the mutual energies between small circular loops that are made by dividing the cross section of the coil. To verify its properties and calculation results, the self-resonant coils are fabricated by using a coaxial cable with characteristic impedance of $50{\Omega}$. The measured frequencies are very consistent with the calculated ones. In addition, the resonant frequency can be adjusted slightly by the tuning parameter ${\gamma}$. The resonant coils are applied to a tablet PC, the Q-factors of the Tx and Rx resonant coils are 282 and 135, respectively. As a result of measurement when height between the two resonant coils is 4.4 cm, the power transfer efficiency is more than 80 % within a radius of 5 cm.

Development of Livestock Traceability System Based on Implantable RFID Sensor Tag with MFAN (MFAN/RFID 생체 삽입형 센서 태그 기반 가축 이력 관리 시스템 개발)

  • Won, Yun-Jae;Kim, Young-Han;Lim, Yongseok;Moon, Yeon-Kug;Lim, Seung-Ok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1318-1327
    • /
    • 2012
  • With the recent increased risk of livestock disease spread and human infection, livestock disease control has become very important. Consequently, there has been an increased attention on an implantable real-time monitoring and traceability system for individual cattle. Therefore, we have developed a robust monitoring and traceability system based on an implantable MFAN/RFID sensor tag. Our design combines the MFAN technology that is capable of robust wireless communication within cattle sheds and the 900MHz RFID technology that is capable of wireless communication without battery. In MFAN/RFID implantable sensor tag monitoring system, UHF sensor tag is implanted under the skin and accurately monitors the body temperature and biological changes without being affected by external environment. In order to acquire power needed by the tag, we install a MFAN/RFID tranceiver on the neck of cattle. The MFAN coordinator passes through the MFAN node and the RFID-reader-combined MFAN/RFID transceiver and transmits/receives the data and power for the sensor tag. The data stored in the MFAN coordinator is transmitted via the internet to the livestock history monitoring system, where it is stored and managed. By developing this system, we hope to alleviate the problems related to livestock disease control.

Intelligent mobile Robot with RSSI based Indoor Location Estimation function (RSSI기반 위치인식기능 지능형 실내 자율 이동로봇)

  • Yoon, Ba-Da;Shin, Jae-Wook;Kim, Seong-Gil;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.449-452
    • /
    • 2007
  • An intelligent robot with RSSI based indoor location estimation function was designed and implemented. A wireless sensor node was attached to the robot to received the location data from the indoor location estimation function. Spartan III was used as the main control device in the mobile robot. The current location data collected from the indoor location estimation system was transferred to the mobile robot and server through Zigbee/IEEE 802.15.4 wireless communication of the sensor node. Once the location data is received, the sensor node senses the direction of the robot head and directs the robot to move to its destination. Indoor location estimation intelligent robot is able to move efficiently and actively to the user appointed location by implementing the proposed obstacles avoidance algorithm. This system is able to monitor real-time environmental data and location of the robot using PC program. Indoor location estimation intelligent robot also can be controlled by executing the instructions sent from the PC program.

  • PDF