• Title/Summary/Keyword: Magnetic signal monitoring

Search Result 55, Processing Time 0.031 seconds

Prediction of Failure for a Motor Stator by Monitoring Magnetic Flux Spectrum in High Frequency Region (고주파 영역 자속 스펙트럼 감시에 의한 전동기 고정자 고장예측)

  • Kim, Dae-Young;Yeo, Yeong-Koo;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.8 no.3
    • /
    • pp.49-54
    • /
    • 2012
  • In this study, the way how we can find the defects of motor windings in advance will be discussed. The magnetic flux spectrum in the high frequency region of the large motor was analyzed based on the actual fault practices related with motor windings. In case of defective motor relative amplitude ratio of the stator slot frequency to its sideband was very high compared to that of healthy motor. And the defective signal related with motor windings was indicated in advance in the magnetic flux spectrum prior to over 1 month before failure. Considering this aspect it can be estimated that magnetic flux spectrum in the high frequency region has the excellent predictive diagnostic capability.

  • PDF

Transcranial Doppler Ultrasonography(TCD) in diagnosis of Cerebrovascular Accident (CVA) (뇌졸중의 진단에 대한 TCD의 활용 (Brain CT, Brain MRI와 Transcranial Doppler Ultrasonography 비교를 통한 뇌졸중 진단의 상호 보완에 관한 연구))

  • Park, Se-Gi;Kang, Myeong-Seog;Jun, Chan-Yong;Park, Chong-Hyeong
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.171-189
    • /
    • 1996
  • Background and Purpose: The greater part of patients to visit Hospital of Oriental Medicine suffer from cerebrovascular accident(CVA). There is transcranial Doppler(TCD) in the diagnostic method to confirm cerebrovascular accident(CVA). Transcranial Doppler(TCD) is an accurate method of monitoring the blood flow velocities of the cerebral vessels and have been generally used to prevent symptomatic vasospasm and confirm cerebral infarction. So we studied, in the crebrovascular accident(CVA), to estimate whether transcranial Doppler(TCD) is useful to. Methods: Using transcranial doppler(Multigon Model 500M Transcranial Doppler System), we measured the mean and peak velocity and the direction of blood flow in 10 cerebrovascular accident(CVA)'s subjects who had been examined by Computed Tomography(CT) or Magnetic Resonance Imaging (MRI). Results : As an anticipation, in cerebrovascular accident(CVA)'s subject with Cb-infarction, the mean and peak velocity of blood flow fell down remarkably and the direction of blood flow was change or irritable. But didn't find out any signal in lacunar infarction. Also, in case with spontaneous hemorrhage, the velocity and direction of blood flow was change but this signal was short of diagnosis for Cb-hemorrhage. Besides, we found signals about embolism, stenosis, thrombosis and occlusion in cerebrovascular accident(CVA)'s subjects. Conclusion: In Cb-infarction, the result of TCD was equal to diagnosis with Computed Tomography(CT) or Magnetic Resonance Imaging (MRI). But about lacunar infarction or spontaneous hemorrhage, signals of TCD couldn't be found out or was insufficient more than Computed Tomography(CT) or Magnetic Resonance Imaging(MRI). In cerebrovascular accident(CVA)'s subject with embolism, stenosis, thrombosis or occlusion, signals of TCD were found out more than Computed Tomography(CT) or Magnetic Resonance Imaging(MRI). Therefore transcranial doppler(TCD) is necessary method which makes a diagnosis of cerebrovascular accident(CVA), with Computed Tomography(CT) or Magnetic Resonance Imaging(MRI).

  • PDF

Remotely controlled Interactive Magnetic Resonance Imaging in Network Environment (Network을 이용한 원격 핵자기 공명 영상)

  • Park, J.I.;Kim, C.Y.;Park, D.J.;Ryu, W.S.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1383-1385
    • /
    • 1996
  • A network based interactive magnetic resonance imaging (MRI) system has been developed using the World Wide Web. For this purpose, an HTTP server is developed on the host computer of the MRI system. Capabilities of video and audio conferencing are included for monitoring experiment. Using the developed system. MRI imaging has been successfully carried out at the Signal Processing Lab in the Kwangwoon University with the remote MRI system located at the Medical Image Research Center at the KAIST in Daejon.

  • PDF

ESR dosimetry and Dating toward $21^{st}$ Century

  • Ikeya, Motoji
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.2
    • /
    • pp.84-88
    • /
    • 2002
  • Dating and dosimetry using electron spin resonance (ESR) in 20th Century developed at both Yamaguchi University and Osaka University have been reviewed with emphasis on new prospects and strategies in 21th century. Natural radiation have been generating radicals that accumulated in archaeological and geological materials. ESR detects these radicals and the ESR signal intensity is proportional to the radiation dose and therefore the age. The assessment of the total dose of natural radiation and the annual dose rate give their ESR ages. The ESR dating of stalactites and stalagmites ant Akiyoshi cave in Yamaguchi prefecture in 1975 was extended to anthropological dating using bones and tooth enamel excavated in Greek Petralona cave. Fossils of shells and corals gave the ages of marine terraces and sea-level changes. Quartz grains gave the ages of geothermal alteration and fault movements. Future ESR dating of ices at outer planets anf their satellite are also investigated as basic studies for ices od $H_2O,\;CO_2,\;SO_2$ as well as terrestrial hydrates in laboratory. Atomic bomb radiation dosimetry at Hiroshima and Nagasaki using ESR lead to the dosimetry of personnel, Chemobyl and JCO criticality accidents. Monitoring of radiation dose with sensitive materials with tissue equivalence are being developed. finally a new scanning ESR imaging apparatus (a near field microwave microscope) developed in our laboratory gave ESR images of Radicals from fossils to Si-CVD and diamond films as summarized in my book in 2002.

  • PDF

Manganese-Enhanced MRI Reveals Brain Circuits Associated with Olfactory Fear Conditioning by Nasal Delivery of Manganese

  • Yang, Ji-ung;Chang, Yongmin;Lee, Taekwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2022
  • Purpose: The survival of organisms critically depends on avoidance responses to life-threatening stimuli. Information about dangerous situations needs to be remembered to produce defensive behavior. To investigate underlying brain regions to process information of danger, manganese-enhanced MRI (MEMRI) was used in olfactory fear-conditioned rats. Materials and Methods: Fear conditioning was conducted in male Sprague-Dawley rats. The animals received nasal injections of manganese chloride solution to monitor brain activation for olfactory information processing. Twenty-four hours after manganese injection, rats were exposed to electric foot shocks with odor cue for one hour. Control rats were exposed to the same odor cue without foot shocks. Forty-eight hours after the conditioning, rats were anesthetized and their brains were scanned with 9.4T MRI. Acquired images were processed and statistical analyses were performed using AFNI. Results: Manganese injection enhanced brain areas involved in olfactory information pathways in T1 weighted images. Rats that received foot shocks showed higher brain activation in the central nucleus of the amygdala, septum, primary motor cortex, and preoptic area. In contrast, control rats displayed greater signals in the orbital cortex and nucleus accumbens. Conclusion: Nasal delivery of manganese solution enhanced olfactory signal pathways in rats. Odor cue paired with foot shocks activated amygdala, the central brain region in fear, and related brain circuits. Use of MEMRI in fear conditioning provides a reliable monitoring technique of brain activation for fear learning.

Development and evaluation of edge devices for injection molding monitoring (사출성형공정 모니터링용 엣지 디바이스 개발 및 평가)

  • Kim, Jong-Sun;Lee, Jun-Han
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.25-39
    • /
    • 2020
  • In this study, an edge device that monitors the injection molding process by measuring the mold vibration(acceleration) signal and the mold surface temperature was developed and evaluated its performance. During injection molding, signals of the injection start, V/P switchover, and packing end sections were obtained through the measurement of the mold vibration and the injection time and packing time were calculated by using the difference between the times of the sections. Then, the mold closed and mold open signals were obtained using a magnetic hall sensor, and cycle time was calculated by using the time difference between the mold closed time each process. As a result of evaluating the performance by comparing the process data monitored by the edge device with the shot data recorded on the injection molding machine, the cycle time, injection time, and packing time showed very small error of 0.70±0.38%, 1.40±1.17%, and 0.69±0.82%, respectively, and the values close to the actual were monitored and the accuracy and reliability of the edge device were confirmed. In addition, it was confirmed that the mold surface temperature measured by the edge device was similar to the actual mold surface temperature.

Application of a Textile-based Inductive Sensor for the Vital Sign Monitoring

  • Gi, Sun Ok;Lee, Young Jae;Koo, Hye Ran;Khang, Seonah;Kim, Kyung-Nam;Kang, Seung-Jin;Lee, Joo Hyeon;Lee, Jeong-Whan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.364-371
    • /
    • 2015
  • In this study, we developed a feasible structure of a textile-based inductive sensor using a machine embroidery method, and applied it to a non-contact type vital sign sensing device based on the principle of magnetic-induced conductivity. The mechanical heart activity signals acquired through the inductive sensor embroidered with conductive textile on fabric were compared with the Lead II ECG signals and with respiration signals, which were simultaneously measured in every case with five subjects. The analysis result showed that the locations of the R-peak in the ECG signal were highly associated with sharp peaks in the signals obtained through the textile-based inductive sensor (r=0.9681). Based on the results, we determined the feasibility of the developed textile-based inductive sensor as a measurement device for the heart rate and respiration characteristics.

Development of a Monitoring Equipment of Current and Potential on Power Transmission Line for 66kV

  • Nisiyama, Eiji;Kuwanami, Kenshi;Kawano, Mitsunori;Matsuda, Toyonori;Oota, I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.41-44
    • /
    • 2003
  • We propose portable equipment that monitors current and voltage of high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to an insulator that supports a power transmission line: A clamped to the power line and the detected current signal is transmitted to the ground station by a wireless optical link using transmission line is detected by a high resistance element, zinc oxide (ZnO). That acts as a potential divider between the power line and ground. We make an experimental device for 66kV power line and demonstrate that it can monitor currents proposed equipment is small-sized, light, and inexpensive in comparison with the conventional CT (current transformer) and PT (potential transformer) since it does not require high potential insulators and magnetic cores, further, the equipment is easily installed owing to its small size and its simple structure.

  • PDF

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.

Successful Motor Evoked Potential Monitoring in Cervical Myelopathy : Related Factors and the Effect of Increased Stimulation Intensity

  • Shim, Hyok Ki;Lee, Jae Meen;Kim, Dong Hwan;Nam, Kyoung Hyup;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.78-87
    • /
    • 2021
  • Objective : Intraoperative neurophysiological monitoring (IONM) has been widely used during spine surgery to reduce or prevent neurologic deficits, however, its application to the surgical management for cervical myelopathy remains controversial. This study aimed to assess the success rate of IONM in patients with cervical myelopathy and to investigate the factors associated with successful baseline monitoring and the effect of increasing the stimulation intensity by focusing on motor evoked potentials (MEPs). Methods : The data of 88 patients who underwent surgery for cervical myelopathy with IONM between January 2016 and June 2018 were retrospectively reviewed. The success rate of baseline MEP monitoring at the initial stimulation of 400 V was investigated. In unmonitorable cases, the stimulation intensity was increased to 999 V, and the success rate final MEP monitoring was reinvestigated. In addition, factors related to the success rate of baseline MEP monitoring were investigated using independent t-test, Wilcoxon rank-sum test, chi-squared test, and Fisher's exact probability test for statistical analysis. The factors included age, sex, body mass index, diabetes mellitus, smoking history, symptom duration, Torg-Pavlov ratio, space available for the cord (SAC), cord compression ratio (CCR), intramedullary increased signal intensity (SI) on magnetic resonance imaging, SI length, SI ratio, the Medical Research Council (MRC) grade, the preoperative modified Nurick grade and Japanese Orthopedic Association (JOA) score. Results : The overall success rate for reliable MEP response was 52.3% after increasing the stimulation intensity. No complications were observed to be associated with increased intensity. The factors related to the success rate of final MEP monitoring were found to be SAC (p<0.001), CCR (p<0.001), MRC grade (p<0.001), preoperative modified Nurick grade (p<0.001), and JOA score (p<0.001). The cut-off score for successful MEP monitoring was 5.67 mm for SAC, 47.33% for the CCR, 3 points for MRC grade, 2 points for the modified Nurick grade, and 12 points for the JOA score. Conclusion : Increasing the stimulation intensity could significantly improve the success rate of baseline MEP monitoring for unmonitorable cases at the initial stimulation in cervical myelopathy. In particular, the SAC, CCR, MRC grade, preoperative Nurick grade and JOA score may be considered as the more important related factors associated with the success rate of MEP monitoring. Therefore, the degree of preoperative neurological functional deficits and the presence of spinal cord compression on imaging could be used as new detailed criteria for the application of IONM in patients with cervical myelopathy.