• Title/Summary/Keyword: Magnetic resonance imaging (MR)

Search Result 887, Processing Time 0.03 seconds

Analysis of fMRI Signal Using Independent Component Analysis (Independent Component Analysis를 이용한 fMRI신호 분석)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.188-195
    • /
    • 1999
  • The fMRI signals are composed of many various signals. It is very difficult to find the accurate parameter for the model of fMRI signal containing only neural activity, though we may estimating the signal patterns by the modeling of several signal components. Besides the nose by the physiologic motion, the motion of object and noise of MR instruments make it more difficult to analyze signals of fMRI. Therefore, it is not easy to select an accurate reference data that can accurately reflect neural activity, and the method of an analysis of various signal patterns containing the information of neural activity is an issue of the post-processing methods for fMRI. In the present study, fMRI data was analyzed with the Independent Component Analysis(ICA) method that doesn't need a priori-knowledge or reference data. ICA can be more effective over the analytic method using cross-correlation analysis and can separate the signal patterns of the signals with delayed response or motion related components. The Principal component Analysis (PCA) threshold, wavelet spatial filtering and analysis of a part of whole images can be used for the reduction of the freedom of data before ICA analysis, and these preceding analyses may be useful for a more effective analysis. As a result, ICA method will be effective for the degree of freedom of the data.

  • PDF

A Study of Optimal SOAmin for Motor and Language Tasks in Event-related fMRI using Stochastic Design (통계학적 자극설계를 이용한 Event-related fMRl에서 운동과 언어과제의 최적 SOAmin에 대한 연구)

  • 문찬홍;유재욱;나동규;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.28-34
    • /
    • 2002
  • Purpose : The minimum stimulus onset asynchronoy(SOAmin) is one of important experimental parameters for an event-related fMRI experiment designed with the stochastic stimulus. In this study, the most efficient SOAmin is explored for the stronger activation in motor and language tasks with the stimulus designed stochastically. Materials and methods : The event-related fMRI during motor and language tasks were obtained in four normal right-handed subjects. EPI-BOLD sequence is used at 1.5Tesla MR system for the acquisition of event-related fMRI. For each task the subjects are responded for the stimulus' with 2, 3, 4, and 6 seconds SOAmin. The obtained images are processed with SPM99, and the p value is set as 0.05 for the significant activation detection. The Z value and the number of activated pixels are compared for each task. Results : For the motor task, the primary and supplementary motor areas are activated, and for the language task the consistent activated signals are detected in the Broca's. The activated signal is to be stronger for the shorter SOAmin for both motor and language tasks. At primary motor area, the activated signals is the strongest for 3 seconds SOAmin and for the supplementary motor area the result with 2 seconds SOAmin shows the strongest activation. And the result of language task shows the strongest activation at the 2 seconds SOAmin. Conclusion : In the event-related fMRI of motor and language tasks with the stochastically designed stimulus, the 2 or 3 seconds SOAmin is efficient for more activated and clustered activation.

  • PDF

Context-Dependent Classification of Multi-Echo MRI Using Bayes Compound Decision Model (Bayes의 복합 의사결정모델을 이용한 다중에코 자기공명영상의 context-dependent 분류)

  • 전준철;권수일
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.179-187
    • /
    • 1999
  • Purpose : This paper introduces a computationally inexpensive context-dependent classification of multi-echo MRI with Bayes compound decision model. In order to produce accurate region segmentation especially in homogeneous area and along boundaries of the regions, we propose a classification method that uses contextual information of local enighborhood system in the image. Material and Methods : The performance of the context free classifier over a statistically heterogeneous image can be improved if the local stationary regions in the image are disassociated from each other through the mechanism of the interaction parameters defined at he local neighborhood level. In order to improve the classification accuracy, we use the contextual information which resolves ambiguities in the class assignment of a pattern based on the labels of the neighboring patterns in classifying the image. Since the data immediately surrounding a given pixel is intimately associated with this given pixel., then if the true nature of the surrounding pixel is known this can be used to extract the true nature of the given pixel. The proposed context-dependent compound decision model uses the compound Bayes decision rule with the contextual information. As for the contextual information in the model, the directional transition probabilities estimated from the local neighborhood system are used for the interaction parameters. Results : The context-dependent classification paradigm with compound Bayesian model for multi-echo MR images is developed. Compared to context free classification which does not consider contextual information, context-dependent classifier show improved classification results especially in homogeneous and along boundaries of regions since contextual information is used during the classification. Conclusion : We introduce a new paradigm to classify multi-echo MRI using clustering analysis and Bayesian compound decision model to improve the classification results.

  • PDF

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

Development of Rabbit Brain Tumor Model Using VX2 Cells and Verification with the MRI in Neuroradiologic Research (Neuroradiology 연구를 위한 VX2 세포를 이용한 토끼 뇌종양 모델 제작과 MRI를 이용한 검증)

  • Yong-Woo Kim;Seon Hee Choi;Hak Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.441-453
    • /
    • 2023
  • Purpose To evaluate the development, location, and volume of a VX2 carcinoma using four inoculation methods in a rabbit brain. Materials and Methods Inoculation of a VX2 cell suspension was performed 1) on the appointed day, 2) seven days after storing a VX2 carcinoma in a freezer or 3) seven days after storing a VX2 carcinoma in a deep freezer after sacrificing the donor rabbits. 4) Without sacrificing the rabbits, the VX2 cell suspension was obtained using a gun biopsy, inoculation was performed on the appointed day. MR imaging was performed 10 days after inoculation. Brain tissues were obtained the day after. The development, location, and volume of the tumor were evaluated. Results Seventeen of the 18 rabbits inoculated on the appointed day developed tumors (average tumor volume, 106.32 mm3). One of five inoculated seven days after storing the VX2 tumor in the freezer, and three of five inoculated seven days after storing the VX2 tumor in the deep freezer developed tumors. Inoculation with a VX2 cell suspension obtained with a gun biopsy from five rabbits revealed development of tumors in only two rabbits. The tumors mostly developed in the superficial cortex. Conclusion TVX2 rabbit brain tumor model is easy to develop and revealed variable reproducibility. This model can be applicable in radiologic imaging, treatment planning, interventional treatment and drug delivery research. VX2 cell can be successfully innoculated into the brain using variable methods under researcher's variable conditions.

Deep Cerebral Venous Thrombosis : Successful Treatment by Systemic Urokinase Followed by Heparin - Case Report - (뇌 심부 정맥 혈전증 : 전신적 유로키나제 혈전용해술 후 헤파린 투여 치료법의 성공 증례 - 증 례 보 고 -)

  • Park, Jae Hyo;Yang, Ji Ho;Yoo, Do Sung;Cho, Kyoung Suok;Huh, Pil Woo;Kwon, Seong Hh;Kim, Dal Soo;Kang, Joon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.99-104
    • /
    • 2001
  • We present two cases of deep cerebral venous thrombosis(DCVT) with the totally occluded straight sinus. A 42-year-old female received with altered mentality . She has taken antihistamine for six years to treat the paranasal sinusitis. Another 34-year-old female who used the oral contraceptive for 11 months presented with acute behavior change . Both of these patients were diagnosed by computed tomography(CT), magnetic resonance(MR) imaging, and cerebral angiography. They were fully recovered with systemic urokinase thrombolysis followed by heparin therapy. We report that the intravenous thrombolysis was potentially effective management strategy in our cases of DCVT with the totally occluded straight sinus.

  • PDF

Prevalence, Distribution, and Significance of Incidental Thoracic Ossification of the Ligamentum Flavum in Korean Patients with Back or Leg Pain : MR-Based Cross Sectional Study

  • Moon, Bong Ju;Kuh, Sung Uk;Kim, Sungjun;Kim, Keun Su;Cho, Yong Eun;Chin, Dong Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.112-118
    • /
    • 2015
  • Objective : Thoracic ossification of the ligamentum flavum (OLF) is a relatively rare disease. Because of ambiguous clinical symptom, it is difficult for early diagnosis of OLF and subsequent treatment can be delayed or missed. Therefore, the purpose of this study is to comprehensively assess the prevalence and distribution of thoracic OLF by magnetic resonance imaging (MRI) and coexisting spinal disease in Korean patients with back pain or leg pain. Methods : The sample included 2134 Korean patients who underwent MRI evaluation for back pain. The prevalence and distribution of thoracic OLF were assessed using lumbar MRI with whole spine sagittal images. Additionally, we examined the presence of coexisting lumbar and cervical diseases. The presence of thoracic OLF as well as clinical parameters such as age, sex, and surgery were retrospectively reviewed. Results : The prevalence of thoracic OLF in total patients was 16.9% (360/2134). The prevalence tended to increase with aging and was higher in women than in men. The lower thoracic segment of T10-11 was the most frequently affected segment. Of the 360 patients with OLF, 31.9% had coexisting herniated thoracic discs at the same level. Approximately 74% of the patients with OLF had coexisting lumbar and cervical disease. Nine (2.5%) of 360 OLF patients underwent surgery for thoracic lesion. Conclusion : The prevalenceof thoracic OLF was relatively higher than those of previous reports. And coexisting lumbar and cervical disease were very frequent. Therefore, we should check coexisting spinal diseases and the exact diagnostic localization of ossification besides lumbar disease.

Acute Intervertebral Disc Protrusion in a Korean Domestic Shorthaired Cat: Clinical and MRI Findings

  • Lee, Narae;Lee, Young-jae;Song, Jin-young;An, Dae-gi;Kang, Byeung-taek;Chang, Jin-hwa;Chang, Dong-woo
    • Journal of Veterinary Clinics
    • /
    • v.34 no.6
    • /
    • pp.467-469
    • /
    • 2017
  • Signalment: A 7-month-old, female domestic shorthaired cat was presented for acute pelvic limb paraparesis. Results: There was no abnormality on survey radiographs and blood analysis, however neurological examination revealed proprioception positioning and hopping was absent in the pelvic limbs. Also, anal tone and perineal sensation were reduced. Magnetic resonance (MR) imaging showed nucleus pulposus dehydration and disc protrusion at T12-T13. Ill-defined diffuse lesion was found at T10-L2 level and it showed isointense on T1-weighted images and hyperintense on T2-weighted and FLAIR images. This lesion was considered as edematous lesion secondary to disc protrusion. The presumptive diagnosis was focal spinal cord edema associated with intervertebral disc protrusion. A traumatic aetiology was suspected. The cat was treated corticosteroids and analgesic and clinical sign improved following 9 days of treatment. Clinical relevance : Intervertebral disc protrusion is rare disease in a cat. However, it could be considered as a cause of paraparesis in cats.

Feline Infectious Peritonitis associated Neuropathy in a Cat (고양이에서 발생한 고양이전염성복막염에 의한 신경병증 증례)

  • Kim, Nam-Kyun;Kim, Min-Ju;Jang, Hyo-Mi;Song, Joong-Hyun;Yu, Do-Hyeon;Hwang, Tae-Sung;Lee, Hee-Chun;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.34 no.5
    • /
    • pp.388-391
    • /
    • 2017
  • A 8-month-old, spayed female, Domestic shorthair cat lived in a shelter was presented with pelvic limbs ataxia and dysuria. Serum biochemical profile abnormalities were hyperproteinemia and decreased albumin/globulin (A:G) ratio (0.70). Results of cerebrospinal fluid (CSF) analysis were mixed cells pleocytosis with predominance neutrophils and an increase in protein concentration. In addition, feline coronavirus was detected by realtime RT-PCR in CSF. Magnetic resonance imaging (MRI) findings revealed lesions of the lumbar spinal cord. Based on clinical signs, MR finding, CSF analysis and realtime RT-PCR result in CSF, this case was diagnosed as feline infectious peritonitis (FIP) associated meningomyelitis. Although prednisolone and mycophenolate mofetil were administrated, clinical signs were not resolved and progressed to tetraplegia and coma status. This case presentation describes that feline infectious peritonitis virus could affect the lumbar spinal cord only and cause meningomyelitis with pelvic limbs ataxia without other neurological signs.