• 제목/요약/키워드: Magnetic resonance imaging (MR)

검색결과 892건 처리시간 0.031초

An Organized Chronic Subdural Hematoma with Partial Calcification in a Child

  • Cho, Hyok-Rae;Kim, Young;Sim, Hong-Bo;Lyo, In-Uck
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권5호
    • /
    • pp.386-388
    • /
    • 2005
  • The authors present a case in which an organized chronic subdural hematoma(CSDH) was incidentally found in a 9-year-old boy with no significant medical history after a pedestrian traffic accident. Preoperative magnetic resonance(MR) imaging showed calcification on the inner membrane and an irregular heterogeneous structure in the hematoma cavity. The findings from the preoperative brain computed tomogram(CT) and MR image were very useful for making the preoperative diagnosis and surgical decision. In choosing the proper surgical strategy for removing the organized CSDH, it was thought that burr hole trephination would present unnecessary difficulties. Thus, craniotomy was selected and the organized CSDH was successfully removed with no complications.

양지밀도강조 고속 스핀에코 자기공명영상을 이용한 슬관절 반월판 열상의 진단 : 고식적 스핀에코를 대체할 수 있는가\ulcorner (Diagnosis of Meniscal Tear of the Knee Using Proton-weighted Fast Spin-Echo MR Imaging : Can be an Alternative to Conventional Spin-Echo Imaging\ulcorner)

  • 김기준;이재희;주종관;이성용
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권1호
    • /
    • pp.73-77
    • /
    • 1999
  • 목적: 슬관절 반월판 열상의 진단에 있어서 양자밀도강도 고속스핀에코영상을 수술소견과 비교하여 진단의 민감도 및 특이도를 분석하여 고식적스핀에코의 대체 방법으로 사용할 수 있는가 알아보고자 하여다. 대상 및 방법: 임상적으로 슬관절 내장층이 의심되어 슬관절 자기공명영상 검사를 시행하고 2개월 이내에 관절경 또는 관혈적 수술을 시행하여 결과가 확진된 102명을 대상으로 하였다. 모든 환자에서 1.5T 영상장치를 사용하여 시상면 및 관상면 양자밀도강도 고속스핀에코 자기공명영상 검사를 시행하였다. 수술 결과를 모르는 3명의 방사선과 의사가 후향적으로 반월판 파열 유무에 대해 분서하고 내측 및 외측 반월판 열상의 민감도 및 특이도를 구하였다. 결과: 양자밀도강조 고속스핀에코 자기공명영상으로 분석한 슬관절 반월판 열상의 민감도 및 특이도는 내측 반월판의 경우 각각 94%, 93% 였고 외측이 경우는 각각 92%, 88% 였다. 결론: 양자밀도강조 고속 스핀에코영상은 반월판 열상의 진단에서 고식적 스핀에코영상과 유사하게 높은 민감도와 특이도를 보였다. 따라서 반월판 영상을 진단하는데 고식적 스핀에코영상의 대체방법으로 사용할 수 있을 것으로 생각한다.

  • PDF

Radiofrequency Coil Design for in vivo Sodium Magnetic Resonance Imaging of Mouse Kidney at 9.4T

  • Lim, Song-I;Woo, Chul-Woong;Kim, Sang-Tae;Choe, Bo-Young;Woo, Dong-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.65-70
    • /
    • 2018
  • The objective of this study was to describe a radiofrequency (RF) coil design for in vivo sodium magnetic resonance imaging (MRI) for use in small animals. Accumulating evidence has indicated the importance and potential of sodium imaging with improved magnet strength (> 7T), faster gradient, better hardware, multi-nucleus imaging methods, and optimal coil design for patient and animal studies. Thus, we developed a saddle-shaped sodium volume coil with a diameter/length of 30/30 mm. To evaluate the efficiency of this coil, bench-level measurement was performed. Unloaded Q value, loaded Q value, and ratio of these two values were estimated to be 352.8, 211.18, and 1.67, respectively. Thereafter, in vivo acquisition of sodium images was performed using normal mice (12 weeks old; n = 5) with a two-dimensional gradient echo sequence and minimized echo time to increase spatial resolution of images. Sodium signal-to-noise ratio in mouse kidneys (renal cortex, medulla, and pelvis) was measured. We successfully acquired sodium MR images of the mouse kidney with high spatial resolution (approximately 0.625 mm) through a combination of sodium-proton coils.

Guidelines for Cardiovascular Magnetic Resonance Imaging from Korean Society of Cardiovascular Imaging (KOSCI) - Part 1: Standardized Protocol

  • Jo, Yeseul;Kim, JeongJae;Park, Chul Hwan;Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae Young;Im, Dong Jin;Hong, Su Jin;Kim, Eun Young;Park, Eun-Ah;Kim, Pan Ki;Yong, Hwan Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.296-315
    • /
    • 2019
  • Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.

Blood-Brain Barrier Experiments with Clinical Magnetic Resonance Imaging and an Immunohistochemical Study

  • Park, Jun-Woo;Kim, Hak-Jin;Song, Geun-Sung;Han, Hyung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권3호
    • /
    • pp.203-209
    • /
    • 2010
  • Objective : The purpose of study was to evaluate the feasibility of brain magnetic resonance (MR) images of the rat obtained using a 1.5T MR machine in several blood-brain barrier (BBB) experiments. Methods : Male Sprague-Dawley rats were used. MR images were obtained using a clinical 1.5T MR machine. A microcatheter was introduced via the femoral artery to the carotid artery. Normal saline (group 1, n = 4), clotted autologous blood (group 2, n = 4), triolein emulsion (group 3, n = 4), and oleic acid emulsion (group 4, n = 4) were infused into the carotid artery through a microcatheter. Conventional and diffusion-weighted images, the apparent coefficient map, perfusion-weighted images, and contrast-enhanced MR images were obtained. Brain tissue was obtained and triphenyltetrazolium chloride (TTC) staining was performed in group 2. Fluorescein isothiocyanate (FITC)-labeled dextran images and endothelial barrier antigen (EBA) studies were performed in group 4. Results : The MR images in group 1 were of good quality. The MR images in group 2 revealed typical findings of acute cerebral infarction. Perfusion defects were noted on the perfusion-weighted images. The MR images in group 3 showed vasogenic edema and contrast enhancement, representing vascular damage. The rats in group 4 had vasogenic edema on the MR images and leakage of dextran on the FITC-labeled dextran image, representing increased vascular permeability. The immune reaction was decreased on the EBA study. Conclusion : Clinical 1.5T MR images using a rat depicted many informative results in the present study. These results can be used in further researches of the BBB using combined clinical MR machines and immunohistochemical examinations.

자화율 차이로 인해 왜곡된 영상으로부터 금속 바늘의 위치 결정 (Determining the Location of Metallic Needle from MR Images Distorted by Susceptibility Difference)

  • 김은주;김대홍
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권2호
    • /
    • pp.87-94
    • /
    • 2010
  • 목적: 금속에 의한 영상 왜곡에 대한 정확한 계산하고 영상으로부터의 금속 물질의 위치 결정한다. 대상 및 방법: 주자기장과 일정 각도를 이루는 무한히 긴 비자성 금속 실린더에 대한 라플라스 방정식을 풀고, 이 결과를 이용하여 절편선택 경사자계와 주파수 부호화 경사자계에 의한 영상에 왜곡을 계산한다. 계산 결과를 바탕으로 하여 왜곡된 영상으로부터 원통형 보철물의 위치를 계산한다. 결과: Folded point와 금속 실린더의 중심 사이의 거리를 영상으로부터 측정하여 계산 결과와 비교한다. 측정 결과와 계산 결과 간의 퍼센트 오차는 한 경우를 제외하고 5% 이내였다. 결론: 금속 실린더가 자기장 하에 있을 때, 영상의 왜곡을 시뮬레이션 하였고, 이 기술은 생검술 또는 외과 수술 등을 자기공명영상법을 이용여 실시간 모니터링하는데 적용할 수 있을 것으로 기대한다.

여성 골반에 생긴 공격성 혈관점액종의 자기공명영상: 증례 보고 (MR Imaging of Aggressive Angiomyxoma of the Female Pelvis: Case Report)

  • 김혜미;표지은;조남훈;김남규;김명진
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.206-210
    • /
    • 2008
  • 공격성 혈관점액종은 여성 생식길에 주로 생기는 드문 종양으로 국소 재발율이 높다. 광범위 국소 절제술을 통해 재발 위험을 줄일 수 있기 때문에 수술 전 진단이 중요하다. 그러나, 이 종양이 드물어 오진되는 경우가 종종 있다. 우리는 수술 전 오진으로 재발한 공격성 혈관점액종 증례와 바르게 진단한 두 증례를 경험하여 보고한다.

  • PDF

다골성섬유형성이상에서 발생한 골육종: 증례 보고 (Osteosarcoma Arising in a Polyostotic Fibrous Dysplasia: A Case Report)

  • 서경진
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권1호
    • /
    • pp.49-53
    • /
    • 2007
  • 섬유형성이상은 골모세포의 비정상적인 분화로 정상 골수와 해면골이 미숙골과 섬유성간질로 대치되는 유전이 되지 않는 골질환이다. 섬유형성이상은 다양한 영상소견을 보이며, 일반적으로 우연히 발견되며 정밀검사가 필요하지 않다. 그러나 섬유형성이상에서 병적골절의 합병증을 보일 수 있고 드물게 악성변이의 합병증을 가진다. 다골성섬유형성이상을 가진 44세 남자환자의 대퇴골에서 방사선소견상 골피질의 파괴와 자기공명영상에서 연부조직종괴를 가진 악성변이의 소견을 보였고, 수술로 절제된 조직학적 검사에서 연골아세포골육종으로 진단 받았다.

  • PDF