• 제목/요약/키워드: Magnetic resonance images

검색결과 1,116건 처리시간 0.033초

Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging

  • Bo Ra Kwon;Jung Min Chang;Soo-Yeon Kim;Su Hyun Lee;Sung Ui Shin;Ann Yi;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제21권11호
    • /
    • pp.1210-1219
    • /
    • 2020
  • Objective: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of handheld ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). Materials and Methods: One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. Results: Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). Conclusion: ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions.

측두하악관절 내장증에서의 관절원판 전상방부착부의 자기공명영상 (MRI findings of the antero-superior attachment of the disc in TMJ internal derangement)

  • 조봉혜;정연화
    • Imaging Science in Dentistry
    • /
    • 제36권2호
    • /
    • pp.73-79
    • /
    • 2006
  • Purpose : To describe the MRI findings of the antero-superior attachment of the disc in patients with internal derangement. Materials and Methods : One hundred fifty-six MR images from 40 normal subjects and 55 abnormal subjects were classified into three study groups of normal, anterior disc displacement with reduction and anterior disc displacement without reduction. On both closed- and open-mouth proton density sagittal images, the depiction of the antero-superior attachment of the disc and its demarcation from the disc were evaluated in three cuts of lateral, central and medial one thirds of the condyle. Results : The depiction of antero-superior attachment was more frequent by the order of normal, anterior disc displacement with reduction and anterior disc displacement without reduction groups, and the significant differences were found on lateral cut of the closed images and lateral and central cuts of the open images. In study for the demarcation between the antero-superior attachment and the disc the lateral cut of the closed images and all three cuts of the open images showed significant differences. Conclusion : Open images are useful to show the difference in depiction of the antero-superior attachment of the disc among the TMJ groups.

  • PDF

MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템 (Head Motion Detection and Alarm System during MRI scanning)

  • 배종원;박해정;김대진
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.55-66
    • /
    • 2012
  • 목적 : 자기공명영상(MRI) 획득시 피험자의 머리 움직임은 영상의 품질에 영향을 줄 수 있다. 영상 왜곡의 발생 원인이 되는 피험자의 움직임을 감지하기 위한 3차원 광학 추적 시스템을 제작하였다. 대상 및 방법 : 시스템은 두 대의 CCD 카메라 및 적외선 조명, 구형 반사 마커, 프레임 그래버(frame grabber)와 데스크탑 컴퓨터로 구성되었다. 두 대의 카메라를 이용하여 마커의 움직임을 관측하는 스테레오 비전 시스템을 제작하고, 카메라의 내부/외부 매개변수를 측정하는 캘리브레이션(calibration)과 측정된 매개변수를 이용하여 3차원 움직임 정보를 계산하는 삼각측량(triangulation)기법을 적용하였다. 캘리브레이션 보드와 피험자용 안경을 제작하여 움직임 추적의 정확도와 실제 MRI 영상 촬영 동안의 움직임 검출의 유효성을 평가하였다. 결과 : 반사 마커가 부착된 안경을 쓴 피험자들이 MRI 영상 촬영 동안 머리를 규칙적으로 움직였을 때, 시스템은 MRI의 고자장 환경 내에서도 영상에 영향을 주지 않고 피험자들의 움직임을 잘 감지했다. 결론 : 제작한 스테레오 비전 시스템은피험자의 머리 움직임을 잘 감지하였고, 실시간 알림 기능을 통해 피험자의 움직임을 중지할 수 있도록 알려줌으로써 MRI 영상에 영향을 주는 것을 최소화할 수 있다.

The Quantitative Diffusion-Tensor Anisotropy of Human Brain Using Fast STEAM DTI

  • 박현정;황문정;김용선;이상권;장용민
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.165-165
    • /
    • 2001
  • Purpose: To obtain quantitative diffusion-tensor anisotropy information of human cerebral structu using turbo STEAM diffusion-tensor imaging. Method: Quantitative diffusion anisotropy MR images were obtained in 7 healthy adults using turbo STEAM sequence and a combination of tetrahedral and orthogonal diffusi gradients. Both relative anisotropy(RA) and fractional anisotropy(FA) values were measured various brain regions. The anisotropy index was then compared with the reported valu resulting from EPI-based diffusion tensor imaging.

  • PDF

The Quantitative Diffusion-Tensor Anisotropy of Human Brain Using Fast STEAM DTI

  • 박현정;황문정;김용선;이상권;장용민
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.138-138
    • /
    • 2001
  • Purpose: To obtain quantitative diffusion-tensor anisotropy information of human cerebral structu using turbo STEAM diffusion-tensor imaging. Method: Quantitative diffusion anisotropy MR images were obtained in 7 healthy adults using turbo STEAM sequence and a combination of tetrahedral and orthogonal diffusi gradients. Both relative anisotropy(RA) and fractional anisotropy(FA) values were measured various brain regions. The anisotropy index was then compared with the reported valu resulting from EPI-based diffusion tensor imaging.

  • PDF

The Diffusion Tensor Imaging of Muscle Preliminary Results

  • 황문정;박현정;장용민;강덕식
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.167-167
    • /
    • 2001
  • Purpose: To obtain normative human skeletal muscle data and evaluate quantitative diffusion-ten anisotropy information using diffusion-tensor imaging technique. Method: Quantitative extremity muscle diffusion tensor MR images were obtained in 5 healt adults by using turbo STEAM sequence and a combination of tetrahedral and orthogon diffusion gradients. Relative anisotropy(RA) and fractional anisotropy(FA) values we measured in soleus and gastrocnemius muscle in addition to mean ADC value.

  • PDF

Performance Evaluation of the JPEG DCT-based Progressive and Hierarchical Codings for Medical Image Communication

  • 안창범;이종수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.48-53
    • /
    • 1991
  • The discrete cosine transform (DCT)-based progressive and hierarchical coding schemes developed by the International Standardization Organization (ISO) Joint Photographic Experts Groups (JPEG) are implemented and evaluated for the application of medical image communication. For a series of head sections of magnetic resonance images, a compression ratio of about 10 is obtained by the algorithm without noticeable image degradation.

  • PDF

상악에서 발생한 석회화를 동반한 치성각화낭 (Odontogenic keratocyst with dystrophic calcifications in the maxilla)

  • 김태영;허경회
    • Imaging Science in Dentistry
    • /
    • 제40권2호
    • /
    • pp.99-101
    • /
    • 2010
  • Odontogenic keratocyst (OKC) with secondary inflammation involving the maxillary sinus was presented. Radiological diagnosis of this case was made based on the various findings from the cone-beam computed tomography, computed tomography and magnetic resonance images. There were calcified materials and impacted tooth within the lumen of the lesion, which is not uncommon in OKC. Histopathologic findings confirmed this lesion as OKC with secondary inflammation.

Primary Uterine Lymphoma: A Case Report

  • In Joo Cheong;Se Hyun Kim;Cheol Min Park
    • Korean Journal of Radiology
    • /
    • 제1권4호
    • /
    • pp.223-225
    • /
    • 2000
  • Primary lymphoma of the uterus is a rare disease, the reported characteristic MR imaging findings being homogeneous intermediate signal intensity of the indistinct mass on T1- and T2-weighted images, and the preservation of endometrial lining and uterine architecture. We report a case of primary uterine lymphoma which showed tumoral necrosis, endometrial disruption and diffuse anterior vaginal wall involvement.

  • PDF