• Title/Summary/Keyword: Magnetic resonance images

Search Result 1,130, Processing Time 0.031 seconds

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

Construction of 3D Geometric Surface Model from Laminated CT Images for the Pubis (치골 부위의 CT 적층 영상을 활용한 3D 기하학적 곡면 모델로의 가공)

  • Hwang, Ho-Jin;Mun, Du-Hwan;Hwang, Jin-Sang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.3
    • /
    • pp.234-242
    • /
    • 2010
  • 3D CAD technology has been extended to a medical area including dental clinic beyond industrial design. The 2D images obtained by CT(Computerized Tomography) and MRI(Magnetic Resonance Imaging) are not intuitive, and thus the volume rendering technique, which transforms 2D data into 3D anatomic information, has been in practical use. This paper has focused on a method and its implementation for forming 3D geometric surface model from laminated CT images of the pubis. The implemented system could support a dental clinic to observe and examine the status of a patient's pubis before implant surgery. The supplement of 3D implant model would help dental surgeons settle operation plans more safely and confidently. It also would be utilized with teaching materials for a practice and training.

Experimental Cats Model for Research of the Blood Ocular Barrier

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.4
    • /
    • pp.555-559
    • /
    • 2005
  • Evaluate the triolein emulsion could disrupt the barriers and to suggest as an experimental model in blood-ocular barrier studies. Triolein emulsion was infused into the carotid artery in the experimental group ten cats. Normal saline was used in another the control group ten cats. Pre contrast and postcontrast T1-weighted MR images were obtained at 30 minutes and 3 hours after embolization. Signal intensities were evaluated in the anterior, posterior chamber and in the vitreus qualitatively and quantitatively. Postembolization 30 minutes MR images were not different from those of the control group. Postembolization 3 hour MR images demonstrated delayed contrast enhancement in the anterior chamber of the ipsilateral and contralateral eyeballs and in the posterior chamber of the ipsilateral eyeball. Delayed contrast enhancement of the posterior chamber of the ipsilateral eyeball was statistically significant (P<0.05). The present study demonstrated significant contrast enhancement in the posterior chamber with infusion of triolein emulsion and can be a model in blood-aqueous barrier studies.

  • PDF

Near Lossless Medical Image Compression using Wavelet Transform (웨이블릿변환을 이용한 무손실에 가까운 의료영상압축)

  • Yoon, Ki-Byung;Ahn, Chang-Beom
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.113-116
    • /
    • 1995
  • Medical image compression using the wavelet transform has been tried. Due to the flexibility in representing nonstationary image signal in both time and frequency domains and its ability to adapt human visual characteristics, wavelet transform has unique advantage in images compression. In the proposed wavelet compression original image is decomposed into multi-scale bands. Different scale factors are employed in the quantization of wavelet decomposed images in different bands. For the lowest band, a predictor is designed and error signal is entropy coded. For high scale bands, runlength coding for toro run is used with Huffman coding. From simulation with magnetic resonance images($256\times256$ size, 256 graylevels) the proposed algorithm is superior to the JPEG by more than 2.5 dB in near lossless compression (CR = 8 - 10).

  • PDF

Analysis of skin movement using MR images (자기공명 영상을 이용한 피부 움직임 분석에 관한 연구)

  • ;Natsuki Miyata;Makiko Kouchi;Masaaki Mochimaru
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.719-722
    • /
    • 2003
  • This paper describes a novel experiment that measures the skin movement of a hand based on MR (magnetic resonance) images in conjunction with surface modeling techniques. The proposed approach consists of 3 phases: (1) MR scanning of a hand with surface makers, (2) 3D reconstruction from the MR images. and (3) registration of the 3D models. The results of registration are used to trace the skin movement with respect to underlying bone motions by measuring the positions of the surface markers.

  • PDF

Intraneural Ganglion of the Digital Nerve of the Hand - A Case Report - (수부에서 수지 신경의 신경내 결절종 - 증례 보고 -)

  • Park, Do-Young;Lee, Yu-Sang;Han, Kyeong-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.78-81
    • /
    • 2011
  • Intraneural ganglia in the upper extremity are rare, and the involvement of the digital nerve of hand has not been reported. The following case report demonstrates a 57-year-old woman with a symptomatic nodular mass on the thenar area of the left hand. Magnetic resonance images showed a lobulated, homogeneous mass of high signal intensity on T2-weighted images and low signal intensity with peripheral enhancement on T1-weighted images. Excisional biopsy and histopathologic examination revealed an intraneural ganglion of the digital nerve of the thumb. Her symptom disappeared immediately after the surgery, and has remained free of abnormal sensation and parestheia for the 3-year follow-up period.

  • PDF

Substantia Nigra after Striatal Infarction on T2- Weighted MR Images

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.3
    • /
    • pp.307-310
    • /
    • 2005
  • Cerebral ischemia results in neuronal changes in remote areas that have fiber connections with the ischemic area. The aim of this study was to investigate the nigral changes by examining the correlation between the apparent diffusion coefficient (ADC) and the tissue structure. Sprague-Dawley rats were subjected to middle cerebral artery occlusion. Four days after the occlusion, when T2-weighted images revealed the presence of an area of high signal intensity in the ipsilateral substantia nigra, and the ADCs were calculated and imaged. Histopathologic examination by both light and electron microscopy was performed on day 4 after surgery. This finding was consistent with the high signal intensity seen on T2-weighted and diffusion-weighted images, as well as with the ADC reduction, but we did not expect to observe uniform ADC reduction attributable mainly to astrocytic swelling in the perivascular end-feet.

  • PDF

Role of Diffusion-weighted MR Imaging in Children with Various Brain Pathologies

  • 최성훈;구현우;고태성;나영신;강신광;김태형
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.99-99
    • /
    • 2003
  • To exhibit our clinical experience of diffusion-weighted (DW) MR imaging for various brain pathologies and to determine its role in characterizing brain pathologies in children. DW images in 177 children (M:F=96:81, mean age, 4.7 years) with various brain pathologies were retrospectively collected over past 3 years. DW images (b value: 1000 s/mm) were reviewed along with corresponding apparent diffusion coefficient (ADC) maps. Brain pathologies included cystic or solid brain tumor (n = 55), cerebral infarct (n = 32), cerebritis with or without brain abscess (n = 21), metabolic or toxic brain disorder (n = 19), demyelinating disease (n = 16), hypoxic-ischemic encephalopathy (n = 16), intracerebral hemorrhage including traumatic brain lesion (n = 15), and posterior reversible leukoencephalopathy (n = 3). We reviewed whether DW images and ADCmaps contribute to further characterization of brain pathologies by defining a chronological age of lesions, the presence of cytotoxic edema in lesions, and the nature of cystic lesions.

  • PDF

The fate of necrosis-avid MR contrast material (Gadophrin-2)-enhanced area of acute reperfused myocardial infarction as determined by MR imaging with Gd-DTPA enhancement and TTC staining after four weeks in a rabbit model

  • Choe, Yeon-Hyeon;Park, Jong-Min;Weinmann, Hanns J.
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.114-114
    • /
    • 2002
  • Purpose: To know the fate of Gadophrin-2-enhanced areas in hearts with acute reperfused myocardial infarction. Method: The left anterior descending branches of coronary arteries were occluded for 90 min and reperfused for 60 min in 15 rabbits. Then, Gadophrin-2 (0.05 mmol/kg) was injected via ear veins. Short-axial T1-weighted spin echo images and fast cine images were obtained 24 hours after injection of Gadophrin-2. After four weeks, short-axial cine MRI was performed and T1-weighted spin echo Images were obtained 5 min and 15 min after injection of Gd-DTPA (0.2 mmol/kg). The animals were sacrificed and short-axial slices of the specimen were stained with 1.5% triphenyltetrazolium chloride (TTC) solution.

  • PDF

Review of Photoacoustic Imaging for Imaging-Guided Spinal Surgery

  • Han, Seung Hee
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.306-322
    • /
    • 2018
  • This review introduces the current technique of photoacoustic imaging as it is applied in imaging-guided surgery (IGS), which provides the surgeon with image visualization and analysis capabilities during surgery. Numerous imaging techniques have been developed to help surgeons perform complex operations more safely and quickly. Although surgeons typically use these kinds of images to visualize targets hidden by bone and other tissues, it is nonetheless more difficult to perform surgery with static reference images (e.g., computed tomography scans and magnetic resonance images) of internal structures. Photoacoustic imaging could enable real-time visualization of regions of interest during surgery. Several researchers have shown that photoacoustic imaging has potential for the noninvasive diagnosis of various types of tissues, including bone. Previous studies of the surgical application of photoacoustic imaging have focused on cancer surgery, but photoacoustic imaging has also recently attracted interest for spinal surgery, because it could be useful for avoiding pedicle breaches and for choosing an appropriate starting point before drilling or pedicle probe insertion. This review describes the current instruments and clinical applications of photoacoustic imaging. Its primary objective is to provide a comprehensive overview of photoacoustic IGS in spinal surgery.