• 제목/요약/키워드: Magnetic resonance images

검색결과 1,124건 처리시간 0.039초

Transient splenial lesion of the corpus callosum in a case of benign convulsion associated with rotaviral gastroenteritis

  • Jang, Yoon-Young;Lee, Kye-Hyang
    • Clinical and Experimental Pediatrics
    • /
    • 제53권9호
    • /
    • pp.859-862
    • /
    • 2010
  • Transient magnetic resonance (MR) signal changes in the splenium of the corpus callosum (SCC) arise from many different conditions, including encephalopathy or encephalitis caused by infection, seizures, metabolic derangements, and asphyxia. Few case reports exist on reversible SCC lesions associated with rotavirus infection. A benign convulsion with mild gastroenteritis (CwG) is frequently associated with rotaviral infections. This entity is characterized by normal laboratory findings, electroencephalogram, neuroimaging, and good prognosis. We report a case of a 2.5-year-old Korean girl with rotavirus-associated CwG demonstrating a reversible SCC lesion on diffusion-weighted MR images. She developed 2 episodes of brief generalized tonic-clonic seizure with mild acute gastroenteritis without any other neurologic abnormality. Stool test for rotavirus antigen was positive. Brain MRI done on the day of admission showed a linear high signal intensity and decreased apparent diffusion coefficient values on the SCC. The lesion completely disappeared on follow-up MRI 6 days later. The patient fully recovered without any sequelae.

생체고분자의 팽윤현상연구를 위한 핵자기공명 현미영상법의 응용 (Application of NMR Microscopy for the Study of the Swelling Effect in Biopolymers)

  • 이동훈;김승수
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.167-172
    • /
    • 1997
  • Novel measurement method has been performed for the noninvasive study of the swelling effect detected in hydrophilic polymers using Magnetic Resonance Microscopy. iN NMR images were acquired to measure geometric changes due to the swelling effect occurred in the polymer specimens. In addition to the geometric changes, the water ingress process was visualized noninvgsively. The measurement method performed .in the present study utilized some of NMR's valuable properties, both noninvasiveness and parameter selectivity. It is believed that the method used in the present study may be applicable to the study of biopolymers in which noninvasiveness is particularly important.

  • PDF

측두하악관절 내장증 환자의 임상증상과 자기공명영상 소견의 비교 연구 (Comparison of MRI findings with clinical symptoms in temporomandibular joint internal derangement)

  • 권기정
    • Imaging Science in Dentistry
    • /
    • 제35권2호
    • /
    • pp.69-75
    • /
    • 2005
  • Purpose : To determine the clinical correlation of magnetic resonance imaging (MRI) findings of temporomandibular joint internal derangements. Materials and Methods : The MR images of 150 TMJs in 75 patients were analyzed. The clinical symptoms were pain in the preauricular area and masticatory muscles and TMJ sounds. Results : There was a statistically significant relationship between the MRI diagnoses of different types of disc displacements and clinical findings of pain, clicking, and crepitus. The risk of TMJ pain was increased when the disc displacement without reduction occurred at the same time in combination with the osteoarthrosis and effusion. Conclusion : Regardless of the results, the data indicate that each of these MR imaging variables may not be regarded as the unique and dominant factor in defining TMJ pain occurrence.

  • PDF

Discrimination of Intervertebral Disk Extrusion from Protrusion with MR Imaging

  • Kim, Jee-Young;Jee, Won-Hee;Ha, Kee-Yong;Park, Chun-Kun;Cho, So-Hee;Byun, Jae-Young
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.138-138
    • /
    • 2002
  • To determine the accuracy of magnetic resonance (MR) imaging for discrimination between intervertebral disk extrusion versus protrusion. MR images of 80 patients who had MR imaging of the spine and confirmed as intervertebral disk extrusion or protrusion were retrospectively reviewed by an experienced musculoskeletal radiologist. A 1.5-T scanner was used. After review of medical records, MR findings of disk extrusion and protrusion were compared using the chi-square test. Intraobserver agreement for differentiation of disk extrusion from protrusion was calculated by using coefficient.

  • PDF

Optimal Region of Interest Location of Test Bolus Technique in Extra Cranial Carotid Contrast Enhanced Magnetic Resonance Angiography

  • Choi, Kwan-Woo;Na, Sa-Ra;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.234-237
    • /
    • 2017
  • This study is aimed to optimize a location of region of interest (ROI) in test bolus carotid contrast enhanced magnetic resonance angiography (CE-MRA) at 3.0T. A total of consecutive 270 patients with no cardiovascular and vessel diseases were selected. Patients underwent elliptical centric 3D CE-MRA with the test bolus technique to identify the individual arterial arrival time. Quantitative measurements were performed by drawing ROIs of $25mm^2$ and signal intensities (SI) were measured in the center of common carotid artery (CCA), internal carotid artery (ICA) and aortic arch (AA). As a result, ROIs located within AA showed a significantly clarified arterial peak and over three times increased SI, while no significant arterial peak time differences were observed compared to ROIs located within CCA. In conclusion, it was demonstrated that the aortic arch is the optimal position to locate ROI in test bolus images of the carotid CE-MRA.

Development of 7-Year-Old Korean Child Model for Computational Dosimetry

  • Lee, Ae-Kyoung;Byun, Jin-Kyu;Park, Jin-Seo;Choi, Hyung-Do;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • 제31권2호
    • /
    • pp.237-239
    • /
    • 2009
  • A whole-body voxel model of a 7-year-old male volunteer was developed from 384 axial magnetic resonance images (MRIs). The MRIs were acquired with intervals of 3 mm for the entire body in a body coil. In order to reduce the MRI acquisition time for the child, the repetition and echo times under T1 weighted image were chosen to be 566 ms and 8 ms, respectively. The MRIs were classified according to 30 types of tissues with known electrical parameters. The developed voxel model was adjusted to the physical average of 7-year-old Korean boys. The body weight of the adjusted model, calculated with the mass tissue densities, is within a 6% difference from the 50th percentile weight.

  • PDF

한방 요법으로 호전된 부골화된 요추 추간판 탈출증 환자에서의 영상의학적 변화 (Magnetic Resonance Imaging Follow-up Study on Two Cases of Lumbar intervertebral Disc Sequestration Patients Treated with Oriental Medicine Treatment)

  • 이기수;홍권의
    • 대한약침학회지
    • /
    • 제14권3호
    • /
    • pp.99-107
    • /
    • 2011
  • Objectives : The purpose of this study is to report the image changes of two cases of Lumbar intervertebral Disc Sequestration after oriental medical treatment. Methods : We examined 2 patients with Lumbar intervertebral Disc Sequestration who showed changes on MRI images before/after the treatment. And we assessed clinical symptoms by using numeric rating scale(NRS) and straight leg raising test(SLRT). Results & Conclusions : In this study, the first MRI examination of Lumbar intervertebral Disc Sequestration patients was performed at the first visit and re-examination of MRI was done after treatment. In each case, the size of the disc sequestration was considerably reduced in MRI image. And both patients represented effective improvment in NRS score and SLRT test angle.

자기공명영상장치의 신호대 잡음비와 영상평가 (Evaluation of Signal to Noise Ratio and Image of Magnetic Resonance Imaging)

  • 이윤;오창현;안창범;이흥규
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.169-172
    • /
    • 1996
  • In this paper, we present the evaluation of signal to noise ratio(SNR) and images of Magnetic resonance imaging system which is underdevelopement. For the evaluation of such parameters, we used two different phantoms, one for SNR and image homogeneity, and the other is for the slice thickness measurement. Further, comparison with other leading MR systems may be needed for the better image quality assessment.

  • PDF

Long-term Chemotherapy with Hydroxyurea in a Dog with Suspected Intracranial Meningioma

  • Jung, Dong-In;Lim, Chae-Young;Kang, Byeong-Teck;Kim, Ju-Won;Yoo, Jong-Hyun;Park, Hee-Myung
    • 한국임상수의학회지
    • /
    • 제25권6호
    • /
    • pp.514-517
    • /
    • 2008
  • A 9-year-old female mixed breed dog was presented due to cluster seizure episode. A mass in the frontal lobe was noted on brain magnetic resonance imaging (MRI). The dural tail sign was identified on contrast MR images. Based on MRI findings, intracranial meningioma was suspected strongly. The patient's symptom was controlled well by a combination therapy of hydroxyurea and prednisolone, and survived for fourteen months after diagnosis. This case report demonstrated that the clinical findings, imaging characteristics of a dog with suspected intracranial meningioma and long-term survival after hydroxyurea plus prednisolone therapy.

"Brain Stunning" Atypical Feature of tPA Thrombolysis Following Aneurysm Embolization

  • Park, Min-Woo;Yi, Hyeong-Joong;Gupta, Rishi;Horowitz, Michael B.
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권4호
    • /
    • pp.300-302
    • /
    • 2006
  • "Stunning" represents prolonged contractile depression of any muscular component after alleviation of severe ischemia, as shown in reperfusion following acute myocardial ischemia or ischemic stroke. Clinically, it presents with no or delayed recovery past to thrombolytic therapy but its pathogenic mechanism is not fully uncovered yet. We describe a unique case of a 63-year-old woman, who was undertaken endovascular coiling for the aneurysms, deteriorated several hours later without known cause, and showed delayed clinical improvement over the next 3 days following thrombolysis. Immediate post-thrombolysis magnetic resonance imaging scan showed no apparent abnormality except for high signal intensity within the corresponding hemisphere. Reversible but delayed nature of " brain stunning" can be explained by these images and it seems to be caused by a certain type of reperfusion injury.