• 제목/요약/키워드: Magnetic resonance frequency analysis

검색결과 81건 처리시간 0.025초

산업용 송풍기의 진동저감에 관한 연구 (A Study on Vibration Reduction of an Industrial Fan)

  • 송승훈;김회룡;정진태
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.457-464
    • /
    • 2000
  • Vibrations of a fan are often generated by mechanical unbalance magnetic force and air flow. These vibrations depend on the design of a fan the machining accuracy of each element and assembled conditions. An experimental study is carried out to reduce the vibration and noise of an industrial fan in this paper. In order to identify the vibration sources of a fan the signal analysis and system analysis are performed, It is shown that the industrial fan studied in this paper has a natural frequency at 144 Hz and resonance occurs when the running speed of the fan is 1750 rpm. The results may be helpful to design a fan with low vibration and noise.

  • PDF

자기공명영상검사용 가돌리늄 경정맥 조영제의 급성 부작용: 부작용 전산 체계를 이용한 후향적 분석 (Acute Adverse Reactions to Gadolinium-based Intravenous Contrast Agents for MRI : Retrospective Analysis Using Computed Reporting System)

  • 최문형;최준일;정승은;안국진;이해규
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권2호
    • /
    • pp.139-145
    • /
    • 2011
  • 목적 : 단일기관에서 발생한 가돌리니움 기반의 자기공명영상 경정맥 조영제의 급성 부작용의 빈도 및 종류, 조영제 별 차이를 알아보았다. 대상 및 방법 : 병원정보시스템의 부작용 보고체계를 분석하여, 2008년 10월부터 2010년 12월 사이에 증례를 검색하였다. 부작용은 경증, 중등도, 중증으로 분류되었고 서로 다른 조영제간에 빈도의 차이가 있는지를 분석하였다. 결과 : 총 33,600건의 조영제가 투여되었고, Gd-BT-DO3A 20,824건 (62%), Gd-DTPA 10,417건 (31%), Gd-EOB-DTPA 2,359건 (7%)이었다. 부작용은 총 39예가 발생하여 빈도는 0.1161%였고, Gd-BT-DO3A 0.1248% (26/39,67%), Gd-DTPA 0.0768% (8/39, 21%), Gd-EOB-DTPA 0.2120% (5/39,13%) 였으며, 조영제 간에 유의한 차이는 없었다. 대부분 (89.7%) 이 경증 부작용이었으며 중등도 및 중증 부작용은 각각 2명에서 발생하였다. 결론 : 한국인에서의 자기공명영상 검사용 경정맥 조영제에 의한 부작용의 빈도는 드물었으며, 특히 중등도 혹은 중증 부작용은 매우 드물었다. 세가지 조영제 사이에 부작용 발생 빈도는 차이는 없었다.

속도변동성분을 갖는 회전디스크의 횡진동 안정성 해석 (Stability Analysis of Transverse Vibration of a Spinning Disk with Speed Fluctuation)

  • 신응수;이기녕;신태명;김옥현
    • 한국소음진동공학회논문집
    • /
    • 제12권1호
    • /
    • pp.21-28
    • /
    • 2002
  • This paper intends to investigate the effects of speed fluctuation caused by the cogging torque in permanent magnetic motors on the stability of the transverse vibration for a spinning disk. Based on the Kirchhoff\`s plate theory and the assumed mode methods, a set of discretized equations of motion were derived for an annular disk rotating with a harmonically varying speed. Then, a perturbation method using the multiple time scales was employed and stability boundaries were determined explicitly in terms of the magnitude and frequency of speed fluctuation, a nominal sped and the modal characteristics of the disk. It is found that parametric resonance occurs at several speed ranges and a single mode or a combination of two modes are involved to cause instability. It is also observed that unstable regions become broadened as the spinning speed increases or two modes are combined in parametric instability. As numerical simulations, stability analysis of a conventional CD-ROM drive was performed. Results of this work can e used as guidelines for motor design and operations with low vibration.

초소형 광디스크 드라이브용 스윙암 방식 로터리 엑츄에이터 설계 및 분석 (Design and Analysis of Swingarm Type Rotary Actuator for Micro ODD)

  • 김동욱;홍어진;박노철;박영필;김수경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.780-785
    • /
    • 2003
  • Recently the trends in information storage devices need small size, mobility, high capacity, and low power consumption etc. To satisfy those, the development of high performance actuator is an important issue. Compared with general linear actuator for optical disk drive, swingarm type rotary actuator is suitable to design in small form factor and has fast access time for random access. Swingarm actuator is designed considering the structural problem and the actuating force of VCM(Voice Coil Motor). The increase of mass caused by optical components makes vibration problems of swing-arm, therefore resonance frequency should be increased and inertia has to be reduced. ANSYS FEM tool is employed in optimizing swingarm. The VCM is designed using 3-D electro-magnetic analysis, and parameters of magnetic circuit are determined to matte large flux density. The large flux density enables to achieve low power consumption. VCM holder is designed to get the mass balance of total actuator and this balance reduces the magnitude of critical mode relative to pivot bearing, It is expected that swingarm type rotary actuator designed by this method is available to variable type of micro optical disk drives.

  • PDF

Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.

Műller Formulation for Analysis of Scattering from 3-D Dielectric Objects with Triangular Patching Model

  • Lee, Chang-Hyun;Cho, Jin-Sang;Jung, Baek-Ho;Sarkar Tapan K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.129-135
    • /
    • 2007
  • In this paper, we present a set of numerical schemes to solve the Muller integral equation for the analysis of electromagnetic scattering from arbitrarily shaped three-dimensional (3-D) dielectric bodies by applying the method of moments (MoM). The piecewise homogeneous dielectric structure is approximated by planar triangular patches. A set of the RWG (Rao, Wilton, Glisson) functions is used for expansion of the equivalent electric and magnetic current densities and a combination of the RWG function and its orthogonal component is used for testing. The objective of this paper is to illustrate that only some testing procedures for the Muller integral equation yield a valid solution even at a frequency corresponding to an internal resonance of the structure. Numerical results for a dielectric sphere are presented and compared with solutions obtained using other formulations.

팬-모터의 구조 및 전자기적 특성을 고려한 선박용 원심 팬의 순음 저감 분석 (Analysis for the Reduction of Tonal Noise in the Centrifugal Fan for the Ship Considering Structural and Electromagnetic Characteristics of the Fan-Motor System)

  • 한형석;장천익;이상구;구자훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.359-367
    • /
    • 2008
  • The maximum sound pressure level in a ship is restricted by the international standard such as MIL-Std. 740-1 in order to protect hearing ability for the crew on a ship. Especially, the noise of a fan system is restricted by the maximum level of the sound power according to the military specification such as MIL-F-1900A. In this paper, the reduction of tonal noise for the fan-motor system on a ship is described related to the electrical as well as structural problems. For the electrical problems, the difference of the magnetic flux caused by the variation of the air-gap is described related to the bad concentricity of the motor housing and the shaft-bearing. And for the structural problem, the resonance of the fan motor system is described.

  • PDF

A comparison of the implant stability among various implant systems: clinical study

  • Kim, Jae-Min;Kim, Sun-Jong;Han, In-Ho;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.31-36
    • /
    • 2009
  • PURPOSE. To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period(24 weeks), without loading. MATERIAL AND METHODS. Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems(group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ(implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS. For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values(group A=0.0022, C=0.017, R=0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position(P > .005) on ISQ values were not significant. CONCLUSIONS. All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months(plateau effect).

Risk factors of ocular involvement in children with mitochondrial respiratory chain complex defect

  • Chae, Jung-Hyun;Lee, Jung-Hun;Kim, Kyo-Ryung;Byeon, Suk-Ho;Lee, Young-Mock;Kang, Hoon-Chul;Lee, Joon-Soo;Kim, Heung-Dong
    • Clinical and Experimental Pediatrics
    • /
    • 제53권12호
    • /
    • pp.994-999
    • /
    • 2010
  • Purpose: Mitochondrial dysfunction can present with various symptoms depending on the organ it has affected. This research tried to analyze the ophthalmologic symptoms and ophthalmologic examination (OE) results in patients with mitochondrial disease (MD). Methods: Seventy-four patients diagnosed with mitochondrial respiratory chain complex defect with biochemical enzyme assay were included in the study. They were divided into 2 groups based on the OE results by funduscopy and were analyzed on the basis of their clinical features, biochemical test results, morphological analysis, and neuroimaging findings. Results: Thirty-seven (50%) of the 74 MD patients developed ophthalmologic symptoms. Abnormal findings were observed in 36 (48.6%) patients during an OE, and 16 (21.6%) of them had no ocular symptoms. Significantly higher rates of prematurity, clinical history of epilepsy or frequent apnea events, abnormal light microscopic findings in muscle pathology, diffuse cerebral atrophy in magnetic resonance imaging, and brainstem hyperintensity and lactate peaks in magnetic resonance spectroscopy were noted in the group with abnormal OE results. Conclusion: Although the ophthalmologic symptoms are not very remarkable in MD patients, an OE is required. When the risk factors mentioned above are observed, a more active approach should be taken in the OE because a higher frequency of ocular involvement can be expected.

휴대폰용 일체형 음향 및 진동 발생장치 개발을 위한 연구 (Study on the Development of Integrated Vibration and Sound Generator)

  • 신태명;안진철
    • 한국소음진동공학회논문집
    • /
    • 제13권11호
    • /
    • pp.875-881
    • /
    • 2003
  • The received signal of a mobile phone is normally sensed through two independent means which are the sound generation of a speaker and vibration generation of a vibration motor. As an improvement scheme to meet the consumer's demand on weight reduction and miniaturization of a mobile phone, the design and development of an integrated vibration and sound generating device are performed in this research. To this purpose, the optimal shapes of the voice coil. the permanent magnet and the vibration plate are designed, and the excitation force applied to the vibration system of the new device is estimated and verified through theoretical analyses, computer simulation, and experiments using an expanded model. In addition, vibration performance comparison of the device with the existing vibration motor is performed, and from the overall process, therefore, the method and procedure for the vibration performance analysis of the integrated vibration and sound generating device are established.