• 제목/요약/키워드: Magnetic resonance frequency analysis

검색결과 81건 처리시간 0.023초

The Analysis of Incidental Findings on Temporomandibular Joint Magnetic Resonance Imaging

  • Choi, Yoon Joo;Lee, Chena;Jeon, Kug Jin;Han, Sang-Sun
    • Journal of Korean Dental Science
    • /
    • 제13권1호
    • /
    • pp.21-27
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the types and frequency of the various incidental findings (IFs) on magnetic resonance images (MRI) taken from the patients with temporomandibular disorder (TMD) symptoms. Materials and Methods: Temporomandibular joint (TMJ) MRI taken from 1,013 patients with TMD symptoms were evaluated retrospectively. IF was defined as imaging features that were accidentally or unexpectedly found, rather than degenerative bony changes of TMJ complex or disc derangement. They were classified into two groups as TMJ site-specific findings and unexpected findings at other regions. The frequency of the sub groups was analyzed. Result: A total of 26 (2.57%) cases with IFs were classified into 13 cases with TMJ site-specific findings and 13 cases with unexpected findings at other region. TMJ site-specific findings included synovial chondromatosis in 6 cases, synovial cyst in 6 cases and osteochondroma in one case. Unexpected findings included salivary gland tumor in 3 cases, developmental cyst in 3 cases, vascular malformation in 2 cases, mastoiditis in 4 cases and sialadenitis on parotid gland in one case. Conclusion: When diagnosing TMD through TMJ MRI, clinicians should carefully read the image, considering the possibility of IFs because TMJ MRI can provide pathologic information in TMJ region and other oral and maxillofacial region.

영구자석 스핀들 모터의 코깅토크가 회전디스크 굽힘 진동의 안정성에 미치는 영향 (Effects of Torque Fluctuation on the Stability of the Transverse Vibration of a Spinning Disk)

  • 이기녕;신응수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.942-947
    • /
    • 2001
  • This paper provides a stability analysis of the transverse vibration of a spinning disk under the torque fluctuation from a permanent magnetic motor. An analytical model has been formulated for a flexible annular disk with its spinning velocity varying harmonically with the same frequency as the cogging torque. A perturbation method based on multiple time scales is applied to perform the stability analysis. Based on expressions for the amplitude and frequency of the parametric excitation, stability boundaries are determined in terms of a nominal spindle velocity, the least common multiple of poles and slots, the magnitude of torque fluctuation and the modal characteristics of. the disk. The stability diagrams predicted by perturbation have been verified numerically using the Floquet theory, which is in good agreement. In conclusion, the fluctuation in spinning velocity is found to affect the stability of the transverse vibration of a rotating disks. The results of this work can be applied to high precision spindle systems such as computer storage systems.

  • PDF

결합 적분방정식을 이용한 삼차원 임의형태 도체 구조물의 전자파 지연산란 해석 (Analysis of Transient Scattering from Arbitrarily Shaped Three-Dimensional Conducting Objects Using Combined Field Integral Equation)

  • 정백호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권11호
    • /
    • pp.551-558
    • /
    • 2002
  • A time-domain combined field integral equation (CFIE) is presented to obtain the transient scattering response from arbitrarily shaped three-dimensional conducting bodies. This formulation is based on a linear combination of the time-domain electric field integral equation (EFIE) with the magnetic field integral equation (MFIE). The time derivative of the magnetic vector potential in EFIE is approximated using a central finite difference approximation and the scalar potential is averaged over time. The time-domain CFIE approach produces results that are accurate and stable when solving for transient scattering responses from conducting objects. The incident spectrum of the field may contain frequency components, which correspond to the internal resonance of the structure. For the numerical solution, we consider both the explicit and implicit scheme and use two different kinds of Gaussian pulses, which may contain frequencies corresponding to the internal resonance. Numerical results for the EFIE, MFIE, and CFIE are presented and compared with those obtained from the inverse discrete Fourier transform (IDFT) of the frequency-domain CFIE solution.

유연 디스크를 위한 고감도 엑추에이터 개발 (Development of High Sensitivity Actuator for Flexible Disk)

  • 송명규;김충;이동주;박노철;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.577-580
    • /
    • 2005
  • This paper reports the high sensitivity actuator for flexible disk. The air stabilized flexible optical disk has very small axial runout. Therefore, It is proper to develop an actuator which has high sensitivity in tracking direction rather than in focusing direction. In order to maximize driving force in radial direction, we present an efficient design of magnetic circuit with simple multi-polarized magnets and auxiliary magnets. Designed magnetic circuit has big force in tracking direction. And we shift 2$^{nd}$ resonance frequency of moving parts Into high frequency band, not causing increase of mass and discord between force and mass centers to secure high sensitivities and sufficient control bandwidth. Finally, experimental results show that designed actuator has superior sensitivity in tracking direction.

  • PDF

활성자극 파라다임 fMRI에서 저주파요동 성분분석 (Low Frequency Fluctuation Component Analysis in Active Stimulation fMRI Paradigm)

  • 나성민;박현정;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권2호
    • /
    • pp.115-120
    • /
    • 2010
  • 목적 : 활성자극 파라다임을 사용한 기능적 자기공명영상 데이터에서 자발적 요동에 해당하는 저주파 BOLD 신호의 존재여부를 규명해 보고자 하였다. 대상 및 방법 : 20명의 여자 양궁선수들과 양궁 경험이 없는 23명의 여자들을 대상으로 finger-tapping 파라다임은 30초간의 운동기와 휴지기를 3회 반복하였다. 혈액산소수준의존(BOLD) fMRI 영상은 3.0 T MR 기기에서 경사자장 반향 EPI 영상을 해부학적 영상은 3차원 T1 강조영상을 사용하였다. 뇌활성화 차이는 SPM-5를 사용하여 분석하였고 저주파 요동성분을 찾기 위해 GIFT 프로그램을 사용하였다. 결과 : 두군 모두에서 finger-tapping에 따라 대뇌좌측의 주운동영역과 보조운동영역 그리고 우측 소뇌에서의 활성화가 관찰되었다. GIFT를 사용한 ICA 분석에서 피검자들의 반측 감각운동망, 동측 감각운동망 그리고 인지기능과 연관된 신경망에 해당하는 독립적인 성분들이 구별되었다. 결론 : Finger-tapping fMRI 데이터에서 BOLD 신호의 자발적 요동에 해당하는 저주파 신호 성분들을 ICA 기법을 사용하여 분리해 낼수 있었고 이러한 독립성분들이 일차운동감각 신경망 그리고 운동 인지기능을 담당하는 신경망의 휴지기 신경활동을 나타낸다는 사실을 규명할 수 있었다.

Analysis of Distance between ATS and ATP Antenna for Normal Operation in Combined On-board Signal System

  • Kim, Minseok;Kim, Minkyu;Kim, Doogyum;Lee, Jongwoo
    • International Journal of Railway
    • /
    • 제5권2호
    • /
    • pp.77-83
    • /
    • 2012
  • Railroad signaling systems are to control intervals and routes of trains. There are ATS, ATP, ATO and ATC system. Trains are operated in the section which is met on the signaling system because various signaling systems are used in Korea. Hence, trains are not operated in the section which is used in the other signaling system. To solve this problem, recently combined on-board system has been developed. The combined on-board system designed by doubling the ATS, ATP and ATC system to ensure the safety of system. The inductance of antenna is change and in return the resonance frequency of antenna is varied by the electromagnetic induction. Therefore, the information signal is not received exactly in the combined on-board system and in return accidents between trains occur. In this paper, electric model of the combined on-board system for considering the ATS and ATP antenna is presented. Moreover, the mutual inductance including the distance between the ATS and ATP antenna is calculated. As a result of the frequency response of the antennas, the mutual inductance met on operation range of resonance frequency is defined.

자기 회로를 이용한 인덕턴스형 변위 측정 시스템의 모델링 및 해석 (Modeling of an Inductive Position Sensing System based on a Magnetic Circuit and its Analysis)

  • 최동준;임춘택;김수현
    • 한국정밀공학회지
    • /
    • 제18권6호
    • /
    • pp.93-101
    • /
    • 2001
  • This paper presents modeling of an inductive micro position sensing system and its analysis. The parameters affected the system response are excitation frequency, turn ratio, input position, air-gap size, load resistance, and geometric dimensions. To analyze the system, we try to establish a modeling based on an equivalent magnetic circuit with permeances. The model is verified by the experimental results from 1 kHz to 20 kHz. The magnetic circuit model is well fitted to the experimental data except a little error due to LC resonance in the large turn-ratio system. Modeling enables us to theoretically approach the response characteristics. Based on the magnetic circuit model, system parameters can be selected in such a way to obtain the required characteristics such as high sensitivity, good linearity, or small size.

  • PDF

Analysis of in vitro 2D-COSY on Human Brain Metabolites for Molecular Stereochemistry

  • Kim, Sang-Young;Woo, Dong-Cheol;Bang, Eun-Jung;Kim, Sang-Soo;Lim, Hyang-Sook;Choi, Chi-Bong;Choe, Bo-Young
    • 한국자기공명학회논문지
    • /
    • 제12권1호
    • /
    • pp.14-25
    • /
    • 2008
  • To investigate the 3-bond connectivity of human brain metabolites by scalar coupling interaction through 2D-correlation spectroscopy (COSY) techniques using high field NMR spectroscopy. All NMR experiments were performed at 298K on Unity Inova 500 or 600 (Varian Inc.) equipped with a triple resonance probe head with z-shield gradient. Human brain metabolites were prepared with 10% $D_2O$. Two dimensional 2D COSY spectra were acquired with 4096 complex data points in $t_2$ and 128 or 256 increments in $t_1$ dimension. The spectral width was 9615.4 Hz and solvent suppression was achieved using presaturation using low power irradiation of the water resonance during 2s of relaxation delay. NMR data were processed using VNMRJ (Varian Instrument) software and all the chemical shifts were referenced to the methyl resonance of N-acetyl aspartate (NAA) peak at 2.0 ppm. Total 10 metabolites such as N-acetyl aspartate (NAA), creatine (Cr), choline (Cho), glutamine (Gln), glutamate (Glu), myo-inositol (Ins), lactate (Lac), taurine (Tau), ${\gamma}$-aminobutyricacid (GABA), alanine (Ala) were included for major target metabolites. Symmetrical 2D-COSY spectra were successfully acquired. Total 14 COSY cross peaks were observed even though there were parallel/orthogonal noisy peaks induced by water suppression. Except for Cr, all of human brain metabolites produced COSY cross peaks. The spectra of NAA methyl proton at 2.02 ppm and Glu methylene proton ($CH_2(3)$) at 2.11 ppm and Gln methylene proton ($CH_2(3)$) at 2.14 ppm were overlapped in the similar resonance frequency between 2.00 ppm and 2.15 ppm. The present study demonstrated that in vitro 2D-COSY represented the 3-bond connectivity of human brain metabolites by scalar coupling interaction. This study could aid in better understanding the interactions between human brain metabolites in vivo 2D-COSY study. Also it would be helpful to determine the molecular stereochemistry in vivo by using two-dimensional MR spectroscopy.

고주파 차폐용 Mesh를 이용한 자기공명영상 분석 (Magnetic Resonance Image Analysis using MESH for High-frequency Shielding)

  • 신운재
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.975-982
    • /
    • 2021
  • 본 연구는 체내의 식도용 스텐트와 일플란트에 많이 사용되는 티타늄 성분의 금속성 물질을 사용하여 구리와 black metal, polyester로 구성된 머리카락 보다 가늘게 제작된 mesh로 시험관을 부분적으로 RF를 차폐하여 주변에 위치한 자기공명영상용 팬텀에 미치는 영향을 평가하고자 하였다. 3T Achieva X-series의 Cardiac Coil을 사용하여 TR 500 ms, TE 20 ms, NEX 1, slice thickness 5 mm의 Spin Echo T1강조영상에서 field of view(FOV)에 따른 자기공명영상을 분석하였다. FOV 304 mm × 304 mm에서는 발생하지 않았던 aliasing artifact가 발생하지 않았지만 250 mm × 250 mm 과 170 mm × 170 mm에서는 발생되었다. FOV 170 mm × 170 mm에서 mesh를 사용하지 않은 경우는 SNR이 78.23으로 가장 낮았으며, mesh를 가운데 세워 분리한 경우에는 215.05, mesh로 완전히 차폐한 경우에는 366.44로 높게 측정되었다. 또한 mesh로 완전히 감싸고 차폐한 경우에는 aliasing artifact도 제거되었고, 영상의 왼쪽과 가운데, 오른쪽의 신호 대 잡음비가 높으면서 다른 조건과 비교하여 균질한 영상을 획득할 수 있었다. 결론적으로 mesh로 RF를 부분적으로 감싸고 차단하면 aliasing artifact를 제거할 수 있고, 작은 FOV를 사용하여 영상의 해상도와 균질성이 우수한 자기공명영상을 획득할 수 있을 것으로 사료된다.

매입형 영구자석 전동기의 전자기력을 고려한 소음특성 분석 (Analysis of Noise Characteristic Considering Magnetic Force of IPM Motor)

  • 이홍주;권중학;이창민;황건용;황상문
    • 한국소음진동공학회논문집
    • /
    • 제19권5호
    • /
    • pp.439-446
    • /
    • 2009
  • Noise sources in electric machines are broadly categorized as magnetic, mechanical, electronic and aerodynamic. Especially, there are several kinds of noise sources due to the change of reluctance by rotor position in IPM motor. To separate acoustic noise by mechanical structure and electromagnetic sources, resonance frequency and the effect of vibration and acoustic noise by electromagnetic sources are analyzed. And then, the structural and electromagnetic designs to reduce acoustic noise are performed. The relevance about the study on noise reduction of IPM motor is verified by noise experiment, noise and vibration analysis.